Страница 1: ...Keysight N1021B 18 GHz Differential TDR TDR Probe Kit User s Guide...

Страница 2: ...n this document are furnished under a license and may be used or copied only in accor dance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S G...

Страница 3: ...sories 6 Using the Probe 7 Proper Handling Techniques 7 Adjusting the Probe Tip Separation 9 Calibrating the Probe 10 Performing an Operation Verification 11 Probing a Differential Trace s Length Midp...

Страница 4: ...4 User s Guide Contents...

Страница 5: ...fferential time domain reflectometry measurements in situations where RF connectors are unavailable It is ideal for use with the Keysight N1055A and 54754A TDR plug in modules Although the N1021B prob...

Страница 6: ...the table search for Parts at www keysight com find parts There are no replaceable parts on the probe Table 1 Items Supplied With N1021B Item Qty Part Number Pair of phase matched cables 1m 1 N1021 6...

Страница 7: ...y electronic components and the input circuits on plug in modules Coaxial cables with both ends unconnected may store electrostatic charges Before connecting any coaxial cable to a device or instrumen...

Страница 8: ...8 User s Guide N1021B Probe Kit Figure 2 Proper Handling Technique...

Страница 9: ...e 9 Adjusting the Probe Tip Separation Turn the probe spacing adjustment wheel to change the spacing between the probe tips Avoid using excessive force at the limits of the adjustment range Figure 3 P...

Страница 10: ...on the search tab and search for the TDR Calibration topic to learn about using the TDR Calibration Setup dialog box Close the help 5 Place the 86100D In TDR mode and open the TDR Calibration Setup di...

Страница 11: ...ensures that the response remains displayed Repeat until the span setting is 50 ps div as shown along the display s bottom edge 5 Center the response 6 Adjust the amplitude position and scale of the r...

Страница 12: ...wo parts traveling in opposing directions away from the probe To the probe it appears that two impedances are connected in parallel The net effect of probing in the middle of traces are as follows The...

Страница 13: ...ce However performance which is deemed grossly different than the listed characteristics will be covered by a 1 year warranty Table 2 Characteristics of TDR Probe Description Characteristic Bandwidth...

Страница 14: ...r is covered by an Keysight maintenance contract it will be repaired under the terms of the warranty or contract If the probe is no longer under warranty or is not covered by an Keysight maintenance p...