Keysight M9709A Startup Guide

Содержание M9709A

Страница 1: ...Startup Guide Keysight M9709A AXIe High Speed Digitizer 32 Channel 8 bit up to 2 GS s DC 500 MHz bandwidth...

Страница 2: ...provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of...

Страница 3: ...s otherwise marked or described in the user documentation Exercise extreme caution when a shock hazard is present Lethal voltage may be present on cable connector jacks or test fixtures The American N...

Страница 4: ...Directive marketing requirement The affixed product label above indicates that you must not discard this electrical electronic product in domestic household waste Product Category With reference to t...

Страница 5: ...ware Requirements 13 Install the Software 13 Keysight IO Libraries Suite IOLS 13 Instrument Software 13 Step 4 Install the Module 15 Multi module synchronization 16 M9709A Front Panel Features 17 Fron...

Страница 6: ...Documentation Map Documentation Map 6 Keysight M9709A Startup Guide...

Страница 7: ...perform instrument connections verify operation and troubleshoot your product Startup Menu Keysight MD2 Digitizer Startup Guides User Manual Provides in depth information and reference material speci...

Страница 8: ...l fifth step shows how to perform an operational verification of the M9709A AXIe High Speed Digitizer Step 1 Unpack and Inspect Step 2 Verify Shipment Step 3 Install Drivers and Software Step 4 Instal...

Страница 9: ...conductive floor mat and heel strap combination Both types when used together provide a significant level of ESD protection Of the two only the table mat and wrist strap combination provides adequate...

Страница 10: ...owner A P O box is not acceptable as a return address Product model number for example M9709A Product serial number The serial number label is located on the top cover of the module The serial number...

Страница 11: ...2781 2 Cable SSMC female to BNC female 1 m M9700 10001 1 Keysight MD2 High Speed Digitizer Software Product Information DVD E2094 60003 1 Keysight IO Libraries Suite M9709 90001 1 Startup Guide in ha...

Страница 12: ...space includes2 1 5 GB for Keysight IO Libraries Suite 1 GB for Keysight MD2 100 MB Display Minimum of 1024 x 768 96 or 120 DPI No display required Browser Use a supported version of Internet Explore...

Страница 13: ...port Center Drivers Firmware Software taband select AXIe Chassis Firmware Install the Software If the Keysight MD2 software is installed on your computer first uninstall the Keysight MD2 software from...

Страница 14: ...ed Digitizer Software Product Information DVD launch the installer 2 Follow the installer prompts Choose a Complete installation to install all soft ware and documentation or a Custom installation to...

Страница 15: ...f the chassis In this case install the M9709A in slot 2 or higher If you are using M9537A AXIe Embedded Controller the chassis M9502A or M9505A firmware has to be updated to the latest version availab...

Страница 16: ...th the interface 7 Power up the chassis It is often necessary to wait until the chassis and its mod ules have completed their start up sequence before proceeding to power up the host controller 8 Rebo...

Страница 17: ...n accept signals up to 15 dBm 1 26 V rms 50 Frequency 3 6 GHz to 4 4 GHz The sampling rate corresponds to the external clock frequency 4 TRG 1 2 3 MCX female These external trigger inputs are DC coupl...

Страница 18: ...ent status White blinking Firmware initialization in progress Green blinking Software initialization in progress Orange blinking Warning see note below Red blinking Error see note below Green OK If wa...

Страница 19: ...talled modules is displayed The instrument properties may be viewed by clicking on the desired instrument from the list on the left Review the configuration data and then click on Start soft front pan...

Страница 20: ...MD2 SFP can be launched from Keysight Connection Expert directly from the Windows Start Menu Keysight MD2 Digitizer Keysight MD2 SFP The Connection window opens with the selection of the digitizer to...

Страница 21: ...tion RF Analog Signal Generator e g Keysight N5181B SSMC cable 50 Coaxial cable with SSMC f A 1 m SSMC to BNC cable is available as an accessory 8121 2781 Delivered with the module A 1 m SSMC to SMA c...

Страница 22: ...the version is not up to date the tool will automatically propose to update the firmware using the Firmware Update Utility Once the Control FPGA firmware has been updated successfully please power of...

Страница 23: ...Step 5 Verify Operation of the M9709A Module Keysight M9709A Startup Guide 23 4 Contact Keysight technical support for assistance Contact details may be found at www keysight com find assist...

Страница 24: ...This information is subject to change without notice Keysight Technologies 2013 2017 Edition 4 June 2017 Printed In USA M9709 90001 www keysight com...