background image

Notices

Copyright Notice

© Keysight Technologies 2016-2017

No part of this manual may be reproduced
in any form or by any means (including
electronic storage and retrieval or
translation into a foreign language)
without prior agreement and written
consent from Keysight Technologies, Inc.
as governed by United States and
international copyright laws.

Manual Part Number

M9703-90012

Published By

Keysight Technologies
Chemin des Aulx, 12
1228 Plan-Les-Ouates
Switzerland

Edition

Edition 2, February, 2017

Regulatory Compliance

This product has been designed and
tested in accordance with accepted
industry standards, and has been
supplied in a safe condition. To review the
Declaration of Conformity, go to

http://www.keysight.com/go/conformity

.

Warranty

THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,” AND IS
SUBJECT TO BEING CHANGED, WITHOUT
NOTICE, IN FUTURE EDITIONS. FURTHER,
TO THE MAXIMUM EXTENT PERMITTED
BY APPLICABLE LAW, KEYSIGHT
DISCLAIMS ALL WARRANTIES, EITHER
EXPRESS OR IMPLIED, WITH REGARD TO
THIS MANUAL AND ANY INFORMATION
CONTAINED HEREIN, INCLUDING BUT
NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR
PURPOSE. KEYSIGHT SHALL NOT BE
LIABLE FOR ERRORS OR FOR
INCIDENTAL OR CONSEQUENTIAL
DAMAGES IN CONNECTION WITH THE
FURNISHING, USE, OR PERFORMANCE
OF THIS DOCUMENT OR OF ANY

INFORMATION CONTAINED HEREIN.
SHOULD KEYSIGHT AND THE USER HAVE
A SEPARATE WRITTEN AGREEMENT
WITH WARRANTY TERMS COVERING
THE MATERIAL IN THIS DOCUMENT THAT
CONFLICT WITH THESE TERMS, THE
WARRANTY TERMS IN THE SEPARATE
AGREEMENT SHALL CONTROL.

KEYSIGHT TECHNOLOGIES DOES NOT
WARRANT THIRD-PARTY SYSTEM-LEVEL
(COMBINATION OF CHASSIS,
CONTROLLERS, MODULES, ETC.)
PERFORMANCE, SAFETY, OR
REGULATORY COMPLIANCE, UNLESS
SPECIFICALLY STATED.

Technology Licenses

The hardware and/or software described
in this document are furnished under a
license and may be used or copied only in
accordance with the terms of such license.

U.S. Government Rights

The Software is “commercial computer
software,” as defined by Federal
Acquisition Regulation (“FAR”) 2.101.
Pursuant to FAR 12.212 and 27.405-3 and
Department of Defense FAR Supplement
(“DFARS”) 227.7202, the U.S. government
acquires commercial computer software
under the same terms by which the
software is customarily provided to the
public. Accordingly, Keysight provides the
Software to U.S. government customers
under its standard commercial license,
which is embodied in its End User License
Agreement (EULA), a copy of which can
be found at

http://www.keysight.com/find/sweula

. The

license set forth in the EULA represents
the exclusive authority by which the U.S.
government may use, modify, distribute,
or disclose the Software. The EULA and
the license set forth therein, does not
require or permit, among other things,
that Keysight: (1) Furnish technical
information related to commercial
computer software or commercial
computer software documentation that is
not customarily provided to the public; or
(2) Relinquish to, or otherwise provide, the
government rights in excess of these
rights customarily provided to the public
to use, modify, reproduce, release,

perform, display, or disclose commercial
computer software or commercial
computer software documentation. No
additional government requirements
beyond those set forth in the EULA shall
apply, except to the extent that those
terms, rights, or licenses are explicitly
required from all providers of commercial
computer software pursuant to the FAR
and the DFARS and are set forth
specifically in writing elsewhere in the
EULA. Keysight shall be under no
obligation to update, revise or otherwise
modify the Software. With respect to any
technical data as defined by FAR 2.101,
pursuant to FAR 12.211 and 27.404.2 and
DFARS 227.7102, the U.S. government
acquires no greater than Limited Rights as
defined in FAR 27.401 or DFAR 227.7103-5
(c), as applicable in any technical data.

Safety Information

Please refer to the Startup Guide or User
Manual which was delivered with your
product for safety information.

Sales and Technical Support

To contact Keysight for sales and technical
support, refer to the “support” links on the
following Keysight web resources:

www.keysight.com/find/digitizer
www.keysight.com/find/assist

(worldwide

contact information for repair and service).

Information on preventing damage to your
Keysight equipment can be found at

www.keysight.com/find/tips

.

Содержание M9703B

Страница 1: ...Configuration and Measurement Instructions Keysight M9703B High Speed Digitizers Hardware Extension of 89600 VSA Software...

Страница 2: ...and 27 405 3 and Department of Defense FAR Supplement DFARS 227 7202 the U S government acquires commercial computer software under the same terms by which the software is customarily provided to the...

Страница 3: ...Hz in interleaved mode SR1 F10 390 MHz 781 MHz in interleaved mode SR2 F05 625 MHz 650 MHz in interleaved mode SR2 F10 625 MHz 1 25 GHz in interleaved mode The present document aims to describe how to...

Страница 4: ...9703B product page www keysight com find M9703B Technical Support Drivers Firmware and Software Once downloaded execute MD2DigitizersHwExt_Setup versions exe and follow the installation process VSA 89...

Страница 5: ...n the MD2 Digitizer Hardware Extension has to be re installed There are two solutions Option 1 From Windows Control Panel Programs Programs and Features select and right click on Keysight MD2 Digitize...

Страница 6: ...the system In order to proceed execute C Program Files Keysight MD2 89600 VSA Connectivity MD2Digitizers 89600VSAIntegration exe or using your installation path Follow the installation process Click...

Страница 7: ...tizer as the VSA measurement input by creating an Analyzer Configuration that uses your digitizer as the Logical Instrument ADC by per forming the following steps a From the menu go to Utilities Hardw...

Страница 8: ...n list 4 e You may either use the default name or specify another name for this ana lyzer configuration 5 f Click OK to close the New Hardware Configuration dialog 6 g Before closing the Hardware Conf...

Страница 9: ...e sig nals please refer to the User manual of your digitizer section Multi Purpose Inputs and Outputs Enable external clock See External Clock page 12 Enable interleaving See Interleaved Mode page 11...

Страница 10: ...the option MD2 Auto Calibration from Input Extensions window then to manually start the calibration once The following calibrations will be automatic However the MD2 Auto Calibration mode is not reco...

Страница 11: ...Interleaving allows to double the sampling rate with the trade off of halving the available center frequency range as shown in the table below Model Option Mode Center Frequency Range ADC Sampling Rat...

Страница 12: ...own in the table below Models Option Frequency Range M9703B SR1 1 8 to 2 GHz SR2 1 8 to 3 2 GHz To use this option first connect an external clock signal in the accepted range to the CLK IN connector...

Страница 13: ...89600 VSA Software Configuration M9703B Hardware Extension of 89600 VSA Software 13...

Страница 14: ...is changed an internal calibration is required if this new configuration has not yet been calibrated in the current session A manual calibration can be performed at any time from the menu Utilities C...

Страница 15: ...izer inputs is Logical Channel Digitizer Input 1 IN1 2 IN3 3 IN5 4 IN7 5 IN2 6 IN4 7 IN6 8 IN8 From the menu Input Analog the following parameters can be set Range Thedigitizer offers several full sca...

Страница 16: ...s from the instantaneous analysis bandwidth IBW supported by the hardware digital down converter the down conversion is done by the hardware at the closest highest IBW and remaining processing is mana...

Страница 17: ...External Magnitude and Channel Delay available for External Magnitude and Channel Trigger Holdoff not supported by the digitizer Soft Front Panel Control The Disconnect feature can be used to pause t...

Страница 18: ...data recording from the digitizer to the PC s disk drive The length of waveform recording time is limited by the memory available on the digitizer Setup Save Recall The digitizer state is not saved w...

Страница 19: ...click on the button to add it to the Configuration box b Select Keysight MD2 digitizers from the list of Possible Logical Instrument and drag it or click on the button to add it to the Configuration...

Страница 20: ...select Input Channel Custom Use the Channel Configuration GUI to reconfigure the channel mapping from the physical hardware input ports to the VSA measurement channel inputs See picture below By defa...

Страница 21: ...s different with a single digitizer and in multi module mode The frequency reference can be accessed from Utilities Frequency reference Using a single digitizer the frequency reference is the internal...

Отзывы: