background image

 11

Unpack and Verify the Shipment Contents

Verify M9410A/M9411A Shipment Contents

Verify M9410A/M9411A Shipment Contents

Please verify the standard shipment contents according to the table below.

The optional cables are listed as below:

Qty

Part Number

Description

1

9230-0333

Envelope-calibration certificate

1

5061-7383

South Korean Class A EMC Declaration

1

9320-6698

China RoHS Addendum

1

9320-6797

Keysight Safety Leaflet

1

M9410-90001

M9410A/M9411A Product DVD

1

M9410-90002

Installation Note

1

M9410-90003

M9410A/M9411A Getting Started Guide

1

M9410-60009

Cable Assembly-MMPX to SMB

1

M9410A/M9411A

M9410A/M9411A VXT Vector Transceiver

Qty

Part Number

Description

1

Y1810A

Cable, MMPX male to SMB male, 260 mm

1

Y1811A

Cable, MMPX male to MMPX male, 200 mm

1

Y1812A

Cable, MMPX male to SMB male, 500 mm

1

Y1813A

Cable, MMPX male to SMB male, 1000 mm

1

Y1814A

Cable, SMA male to SMA male, 1220 mm

1

Y1815A

Cable, MMPX male to BNC male, 1500 mm

All the manuals and software contained on the DVD are available from 

www.keysight.com/find/m9410a

www.keysight.com/find/m9411a

Содержание M9411A

Страница 1: ...Keysight M9410A M9411A VXT PXIe Vector Transceiver Getting Started Guide...

Страница 2: ...government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The license set f...

Страница 3: ...This chapter provides the process to unpack and verify the contents of the signal transceiver 2 Installing Hardwares Refer to this chapter to install all the needed hardwares in a PXI Express chassis...

Страница 4: ...1A product pages on keysight com go to Document Library Manuals To receive the latest updates by email subscribe to Keysight Email Updates at the following URL http www keysight com find emailupdates...

Страница 5: ...t Panel Overview 19 M9300A Reference Preparation 21 3 Software Installation and Licensing Get the M9410A M9411A software 26 Software Installation 27 Uninstalling the Software 31 If Installation Fails...

Страница 6: ...es 55 Launch Modular TRX Application by IVI driver 55 5 Using Modular TRX application Remote Desktop Using the M9410A M9411A Remotely 58 Overview of Remote Desktop operation 58 Setting up Remote Deskt...

Страница 7: ...Contents 7 6 Service Information Calling Keysight Technologies 72 Locations for Keysight Technologies 72 Read the Warranty 73 Service Options 73...

Страница 8: ...8 Contents...

Страница 9: ...nd Verify the Shipment Contents This section explains how to verify the shipment contents when you receive the shipment The following topics can be found in this section Initial Inspection on page 10...

Страница 10: ...Technologies office Keep the shipping materials for the carrier s inspection If you must return a transceiver to Keysight Technologies use the original or comparable shipping materials The modules ar...

Страница 11: ...0 90001 M9410A M9411A Product DVD 1 M9410 90002 Installation Note 1 M9410 90003 M9410A M9411A Getting Started Guide 1 M9410 60009 Cable Assembly MMPX to SMB 1 M9410A M9411A M9410A M9411A VXT Vector Tr...

Страница 12: ...so a symbol of an Industrial Scientific and Medical Group 1 Class A product CISPR 11 Clause 4 This symbol indicates separate collection for electrical and electronic equipment mandated under EU law as...

Страница 13: ...Hardware Installation This chapter describes the preparation of hardware for M9410A M9411A VXT Vector Transceiver Chassis and Controller Preparation on page 14 Install Modules on page 16 M9410A M9411A...

Страница 14: ...Requirements Chassis PXIe or PXI H chassis slot Keysight M9018B M9019A PXIe chassis is recommended Controller Embedded controller Keysight M9037A or an equivalent embedded controller that meets the fo...

Страница 15: ...teps 1 Refer to Install Modules on page 16 to Install the embedded controller module into a compatible chassis 2 Connect peripherals mouse keyboard monitor 3 Power up the chassis after all the modular...

Страница 16: ...d reliability of test Set chassis fans to high or auto Do not disable fans Position chassis to allow plenty of space around chassis air intake and fan exhaust At environment temperatures above 45 C se...

Страница 17: ...ce between the chassis fan intake and exhaust vents Blockage by walls or obstructions affects the air flow needed for cooling 5 Before inserting the module into the chassis back the mounting screws ou...

Страница 18: ...may suffer if the screws are not tightened properly 9 Verify the PXI chassis fans are operable and free of dust and other contaminants that may restrict airflow 10 Install filler panels and slot bloc...

Страница 19: ...minal 2 RF Output RF output port SMA female connector 50 nominal Maximum reverse input power 30 dBm 3 100 MHz In 100 MHz reference input MMPX female connector 50 nominal 4 4 8 GHz Out 4 8 GHz timebase...

Страница 20: ...r 50 nominal Input level range 3 3 V to 3 3 V Output impedance 50 nominal Output level range 3 3 V LVTTL 9 RF Input RF Input port Maximum average input power 27 dBm 10 Trig 2 Receiver or Source Trigge...

Страница 21: ...nce signal input is present to M9410A M9411A 100 MHz In port before starting software of M9410A M9411A Keysight M9300A Reference module is recommended for inputting the reference signal Refer to Insta...

Страница 22: ...e and enable the output reference signal correctly 1 Click to run the M9300A Soft Front Panel software The connection window below will pop up 2 Click Connect The soft front panel window will pop up a...

Страница 23: ...r message window If the reference signal input is not detected correctly there will be a warning as following on status bar of Modular TRX application window Check the reference signal input and make...

Страница 24: ...24 Hardware Installation M9300A Reference Preparation...

Страница 25: ...ice LXI server The M9410A M9411A software offers a standard IQ analyzer measurement application and some additional measurement applications Each application requires a license to execute the software...

Страница 26: ...411A Software and Product information DVD M9410 90001 If there is not DVD drive on your controller please use USB storage device or remote access via LAN to copy the software installation package for...

Страница 27: ...ill be extracted first as following 3 Click Yes to continue the installation after confirming the requirements The installation file will be extracted 4 After passing the requirements check if a modul...

Страница 28: ...ar vector signal transceiver application will be shown as following The installation includes possible FPGA re programming If the AC power is interrupted during installation process it could render yo...

Страница 29: ...ation click Next to continue the installation 8 InstallShield Wizard is ready to begin installation click Install to install the Modular Vector Signal Transceiver Application During installation proce...

Страница 30: ...ions that will be loaded when the application is launching Please refer to Configure Application Tool on page 44 for further information If there is no FPGA update during installation process a prompt...

Страница 31: ...nction Verification Making a Basic Measurement on page 67 to verify the function Uninstalling the Software You can uninstall the software from the Uninstall or change a program window Click Control Pa...

Страница 32: ...ree space on drive C is required for software installation If there is not enough space the requirements check will be failed Please clean up your disk and try again Not run as administrator The messa...

Страница 33: ...below Components installation failure Software installation includes the following sub components installation IO libraries suite HPP License manager License service LXI server If the components is no...

Страница 34: ...Transceiver uses four licensing types for measurement applications F Fixed licenses T Transportable licenses N Network licenses U USB Portable licenses And there are 5 terms attached to the license to...

Страница 35: ...r experience is identical between instruments This is particularly important when transporting the license for a newly released application which may only be available in the latest software release N...

Страница 36: ...a and so is acceptable to high security A D customers Transporting licenses from one instrument to another just requires moving the dongle and license files to the desired instrument The license files...

Страница 37: ...License Manager select Start a floating license server with a license file and add files containing the USB Portable licenses desired To set up Network licenses in the Keysight Floating License Manage...

Страница 38: ...ation fixed license with a USB storage device on the controller No calibration is required after a measurement application installation Step Action Notes 1 Redeem the Option Upgrade Entitlement Certif...

Страница 39: ...r other license types Transportable licenses use the Keysight License Manager to perform a transport Network licenses are loaded on the server and set up with the Keysight Floating License Manager USB...

Страница 40: ...nse 2 Place the license file either on a network connected driver or any other place where the controller can access it 3 Starting License Manager To start Keysight License Manager from the Windows St...

Страница 41: ...icense file s and then click the Open button The license is automatically installed from the previously selected license file and now appears in the license list as an installed license under the syst...

Страница 42: ...e connected to a LAN If you do not have this recommended network configuration see the Keysight License Manager Help for details on how to transport a license If you have the recommended network confi...

Страница 43: ...ide 4 Launching Modular TRX Application This chapter provides the information on how to launch a Modular TRX application with topics below Configure Application Tool on page 44 Application Launcher on...

Страница 44: ...the modular product selection window will pop up Please select the wanted modular and the following window will pop up Follow the instructions in this dialog to configure your applications as desired...

Страница 45: ...her starting process will check if there is any hardware license available for the installed modules If there is any hardware license installed In License Manager but not upgraded to module hardware t...

Страница 46: ...tically During the FPGA updating a message box will be shown as following and the LED on the module will be in Fast Blink mode A window of Update FPGA Status will be shown during the FPGA update proce...

Страница 47: ...t module will be checked Chassis Number Shows the Chassis Number in which the module is inserted in This column will only be visible when there is chassis number greater than 1 When there is only one...

Страница 48: ...aunch Type is Manual Or Auto and the Status state is Idle the Modular TRX application will be launched and connected to the indicated M9410A M9411A module In addition the configurations will be saved...

Страница 49: ...the Modular TRX application by pressing Run Selected button with the check box for the module selected Disabled If the launch type is Disabled the Modular TRX application will not be launched on the...

Страница 50: ...es for a module with a controller You need to provide these information when you are redeeming licenses Use Copy button to copy the selected module host information text for the selected module The co...

Страница 51: ...cense Manager on page 40 2 Open launcher and click Module License button the module license window with available hardware licenses you installed in step 1 will be shown as following 3 Click Install A...

Страница 52: ...dules If multiple installed modules with Idle status are selected multiple modular TRX application instances will run with each module after Run Selected button is clicked If a module is already runni...

Страница 53: ...the steps below to configure the argument of LaunchModularTRX exe launching Modular TRX Application automatically 1 Right click on the LaunchModularTRX exe icon on desktop and choose Properties 2 On...

Страница 54: ...instance will be launched with the module with the PXI VISA address you input With this method you can only launch modular TRX application instance with one specified module PXI VISA address of the mo...

Страница 55: ...variety of development environments IVI drivers allow you to programmatically control your instrumentation while providing a greater degree of instrument interchangeability and code reuse For M9410A M...

Страница 56: ...56 Launching Modular TRX Application Launching Modular TRX Application with Launcher...

Страница 57: ...me guidelines for using the capabilities with the instrument You need to refer to the Windows 10 help documentation for more information Your version of Windows may not match these instructions exactl...

Страница 58: ...he screen of the remote computer This section provides full details of how to set up the controller for remote connectivity and also how to set up a computer running any version of Microsoft Windows a...

Страница 59: ...remote computer to the controller you need to know its Computer Name or IP address Those information can be displayed as follows Table 5 1 Setting up a remote desktop connection Step Action 1 On the...

Страница 60: ...n Manually on page 52 to launch the Modular TRX application on your remote computer Ending a Remote Desktop session To disconnect the remote computer from controller ending the session Table 5 3 Start...

Страница 61: ...e Center Frequency the invalid data indicator will display until a new sweep has completed If any Trace is in View mode displaying but not updating and the settings are changed the invalid data indica...

Страница 62: ...wing dialog This dialog allows you to choose a Mode Measurement and View When you select a mode the measurements that are available in the mode are displayed in the Measurement column When you select...

Страница 63: ...gs and information The annotations on this bar can be used to change settings Tap anywhere in the annotation box to access the drop down panel that contains relevant parameters The following graphic s...

Страница 64: ...ap by mouse On the signal Scroll changes the active function parameter Horizontal drag changes the center frequency Vertical drag changes the reference level Markers may be moved by dragging them to t...

Страница 65: ...5 Using Modular TRX application Display Features Menu Panel At the top of the menu panels are two icons The Preset icon accesses the following control menu The System icon accesses the following dialo...

Страница 66: ...the measurement controls Notice that the Frequency panel has a Settings tab on the right side Other panels may have multiple tabs The tabs access controls for the particular parameter noted on the tab...

Страница 67: ...se refer to Launch Modular TRX Application Automatically on page 53 for the detailed procedure 3 Set source to generate a CW signal and use receiver to observe this signal 1 Press Input Output RF Sour...

Страница 68: ...to compensate for the gains and losses of external devices External Gain and Corrections are under the Input Output menu and Ref Lvl Offset is under the Amplitude menu Operator is responsible to main...

Страница 69: ...the bottom bar or right click on your mouse and select Help the help screen will be displayed as following You can navigate to any menu and by clicking on soft key the help information of the soft key...

Страница 70: ...70 Using Modular TRX application Using the Interactive Help System...

Страница 71: ...0A M9411A VXT Vector Transceiver Getting Started Guide 6 Service Information This chapter provides the basic service information such as how to return a transceiver to service Calling Keysight Technol...

Страница 72: ...anada 1 877 894 4414 Latin America 305 269 7500 United States 1 800 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0 120 421 345 Korea...

Страница 73: ...e be familiar with its terms Service Options Keysight Technologies offers several optional maintenance plans to service your transceiver after the warranty has expired Call your Keysight Technologies...

Страница 74: ...This information is subject to change without notice Keysight Technologies 2018 2019 Edition 1 March 2019 M9410 90003 www keysight com...

Отзывы: