4 Mode Functions
Mode
Mode
The Mode key allows you to select the available measurement applications or “Modes”. Modes are a
collection of measurement capabilities packaged together to provide an instrument personality that is
specific to your measurement needs. Each application software product is ordered separately by Model
Number and must be licensed to be available. Once an instrument mode is selected, only the commands
that are valid for that mode can be executed.
Key operation can be different between modes. The information displayed in Help is about the current
mode.
To access Help for a different Mode you must first exit Help (by pressing the Cancel (Esc) key). Then select
the desired mode and re-access Help.
For more information on Modes, preloading Modes, and memory requirements for Modes,
see
"More Information" on page 131
Key Path
Front-panel key
Remote Command
:INSTrument[:SELect] SA | RTSA | SEQAN | EMI | BASIC | WCDMA | EDGEGSM
| WIMAXOFDMA | VSA | PNOISE | NFIGure | ADEMOD | BTooth | TDSCDMA |
CDMA2K | CDMA1XEV | LTE | LTETDD | LTEAFDD | LTEATDD | MSR | DVB | DTMB
| DCTV | ISDBT | CMMB | WLAN | CWLAN | CWIMAXOFDM | WIMAXFIXED | IDEN |
RLC | SCPILC | VSA89601
:INSTrument[:SELect]?
Example
:INST SA
Notes
The available parameters are dependent upon installed and licensed applications resident in the
instrument. Parameters given here are an example, specific parameters are in the individual
Application.
A list of the valid mode choices is returned with the INST:CAT? Query.
Preset
This is unaffected by a Preset but is set on a “Restore System Defaults->All” to:
State Saved
Saved in instrument state
Backwards
Compatibility SCPI
:INSTrument[:SELect] GSM
provided forbackwards compatibility. Mapped to EDGEGSM.
Backwards
Compatibility SCPI
:INSTrument[:SELect] SANalyzer
provided for ESU compatibility. When this command is received, the analyzer aliases it to the
following:
INST:SEL SCPILC
This results in the analyzer being placed in SCPI Language Compatibility Mode, in order to emulate
the ESU Spectrum Analyzer Mode.
Backwards
Compatibility SCPI
:INSTrument[:SELect] RECeiver
provided for ESU compatibility. When this command is received, the analyzer aliases it to the
following:
:INST:SEL EMI
:CONF FSC
130
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...