1-12
LOAD CONSIDERATIONS
This section provides information on operating your supply
with various types of loads connected to its output.
PULSE LOADING
The power supply will automatically cross over from constant-
voltage to current-limit operation in response to an increase in
the output current over the preset limit. Although the preset
limit may be set higher than the average output current, high
peak currents (as occur in pulse loading) may exceed the pre-
set current limit and cause crossover to occur and degrade
performance.
REVERSE CURRENT LOADING
An active load connected to the supply may actually deliver a
reverse current to the supply during a portion of its operating
cycle. An external source cannot be allowed to pump current
into the supply without risking loss of regulation and possible
damage to the output capacitor of the supply. To avoid these
effects, it is necessary to preload the supply with a dummy
load resistor so that the supply delivers current through the
entire operating cycle of the load devices.
Figure 3. Reverse Current Loading Solution
OUTPUT CAPACITANCE
An internal capacitor across the output terminals of the supply
helps to supply high-current pulses of short duration during
constant-voltage operation. Any capacitance added externally
will improve the pulse current capability, but will decrease the
load protection provided by the current limiting circuit. A high-
current pulse may damage load components before the aver-
age output current is large enough to cause the current limit-
ing circuit to operate.
REVERSE VOLTAGE PROTECTION
A diode is connected across the output terminals with reverse
polarity. This diode protects the output electrolytic capacitors
and the series regulator transistors from the effects of a
reverse voltage applied across the output terminals. Since
series regulator transistors cannot withstand reverse voltage
either, diodes are also connected across them. When operat-
ing supplies in parallel, these diodes protect an unenergized
supply that is in parallel with an energized supply.
Содержание e3620a
Страница 1: ...Keysight E3620A Dual Output Power Supply Operating and Service Manual ...
Страница 2: ......
Страница 3: ...1 1 ...
Страница 21: ...A 7 COMPONENT LOCATOR DIAGRAMS MAIN BOARD TOP ...
Страница 22: ...A 8 MAIN BOARD BOTTOM ...
Страница 23: ...A 9 DISPLAY CONTROLLER TOP ...
Страница 24: ...A 10 DISPLAY CONTROLLER BOTTOM ...
Страница 25: ...A 11 7 SEGMENT TOP ...
Страница 26: ...A 12 7 SEGMENT BOTTOM ...