background image

Operating and Service

3

Keysight

 87421/2A Power Supply Operating and Service Manual

23

Service Information

The power supplies contain no user serviceable parts (with the 
exception of the fuse). If service is required, contact your 
nearest 

Keysight

 Technologies Service Center. Refer to 

“Contacting 

Keysight

 

on page

 

4.

Available Instruments and Accessories

83006A microwave system amplifier 0.01- 26.5GHz

83017A microwave system amplifier 0.5- 26.5GHz

83018A microwave system amplifier 2- 26.5GHz

83020A microwave system power amplifier 2- 26.5GHz

87415A microwave system amplifier 2- 8GHz

87405C microwave system pre- amplifier 0.1- 18GHz

83440- 60009 lightwave converter power supply adapter

Содержание 87421A

Страница 1: ...Keysight 87421 2A Power Supply Operating and Service Manual ...

Страница 2: ......

Страница 3: ......

Страница 4: ...se and may be used or copied only in accor dance with the terms of such license Restricted Rights Legend U S Government Restricted Rights Soft ware and technical data rights granted to the federal government include only those rights customarily provided to end user cus tomers Keysight provides this customary commercial license in Software and techni cal data pursuant to FAR 12 211 Technical Data ...

Страница 5: ...u must not discard this electrical electronic product in domestic household waste Product Category With reference to the equipment types in the WEEE Directive Annex I this product is classed as a Monitoring and Control Instrumentation product Do not dispose in domestic household waste To return unwanted products contact your local Keysight office or see www keysight com for more information ...

Страница 6: ...d 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 81 426 56 7832 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008 Europe Austria Belgium Denmark Finland France Germany Ireland Italy Netherlands Spain Sweden Switzerland French Switzerland German United Kingdom Other European Countries 0820 87 44 11 32 0 2 404 93 40 45 70 13 15 15 358 0 10 855 2100 0825 010 700 01805 24 6333...

Страница 7: ...o the instrument s instruction manual for important information This symbol indicates hazardous voltages The laser radiation symbol is marked on products that have a laser output This symbol indicates that the instrument requires alternating current ac input The CE mark is a registered trademark of the European Community If it is accompanied by a year it indicates the year the design was proven Th...

Страница 8: ...ower source as described in the input power configuration instructions in this manual If this product is to be powered by autotransformer make sure the common terminal is connected to neutral grounded side of the ac power supply ICES NMB 001 ICES NMB 001 indicates that this ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme a la norme NMB 001 du Canada ff N10149 The C Tick ma...

Страница 9: ...r Supply Operating and Service Manual 7 Declaration of Conformity A copy of the Manufacturer s Declaration of Comformity for this instrument can be obtained by contacting your local Keysight Technologies sales representative ...

Страница 10: ...8 Keysight 87421 2A Power Supply Operating and ...

Страница 11: ...anual 9 Contents 1 Introduction 11 Product Overview 12 87421A Power Supply 12 87422A Power Supply 13 2 Specifications 15 Product Specifications 16 Physical Specifications 17 Environment Specifications 19 3 Operating and Service 21 Operating and Service 22 ...

Страница 12: ...10 Keysight 87421 2A Power Supply Operating and Service Manual Contents ...

Страница 13: ...Power Supply Operating and Service Manual 1 Introduction Product Overview 12 87421A Power Supply on page 12 87422A Power Supply on page 13 This chapter provides you the overview of Keysight 87421A and 87422A power supply ...

Страница 14: ...stem amplifiers The power supply includes an AC power cord with protective ground for connection to 100 240Vac Also included is a 2 meter cable with a 3 pin connector on one end and a D subminiature connector 83006 60005 on the other end for direct connection to the microwave system amplifiers The 87421A may also be used to provide bias voltages for the 83440C high speed lightwave converter Using ...

Страница 15: ...amplifier One additional 12V dc output is provided to power a preamplifier such as the 83006A or 83017A The power supply includes an AC power cord with protective ground for connection to 100 240Vac and two 2 meter cables one cable 83006 60005 with a 3 pin connector on one end and a D subminiature connector on the other end one cable 87422 60001 for direct connection to the 83020A amplifier ...

Страница 16: ...14 Keysight 87421 2A Power Supply Operating and Service Manual 1 Introduction ...

Страница 17: ... Supply Operating and Service Manual 2 Specifications Product Specifications 16 Physical Specifications 17 Environment Specifications 19 This chapter provides you the specifications of Keysight 87421A and 87422A power supply ...

Страница 18: ...ation 20 to full load 2 0 1 0 Output ripple 25mV RMS max 25mV RMS max Output noise 2 peak to peak max 2 peak to peak max Overvoltage limit protected Yes Yes Short circuit protection Current limited for overload and short circuit protection Normal operation returns upon removal of overload Current limited for overload and short circuit protection Normal operation returns upon removal of overload AC...

Страница 19: ...nsions Figure 2 Figure 3 Weight 0 9kg 2 0lb 2 1kg 4 6lb Shipping Weight 1 8kg 4 0lb 3 2kg 7 0lb Figure 2 Mechanical Dimension of 87421A Tol 0 2 0 008 14 5 0 57 57 2 2 25 175 8 6 92 163 1 6 42 148 6 5 85 63 5 2 50 5 0 0 197 25 4 1 00 DC Output Pin No 1 114 3 4 50 57 2 2 25 Fuse AC Input 83006 60005 Pin No 1 2000 79 Dimensions in milimeters inches ...

Страница 20: ... Figure 3 Mechanical Dimension of 87422A 87 42 2A P OW ER SU PPLY 274 0 10 9 254 0 10 0 166 0 6 5 21 8 86 6 5 0 26 Top Panel 3 3 13 R typ 12 0 47 202 0 8 0 85 5 3 4 83006 60005 2000 79 Pin No 1 Pin No 1 87422 60001 Note 18 gauge wire minimum 2000 79 Dimensions in milimeters inches ...

Страница 21: ...dling Shock Half sine shock 3ms duration 155in s ΔV minimum 3 shocks each face Transportation Shock Type 1 Trapezoid shock 30g accelaration 292in s ΔV minimum 3 shocks each face Vibration Operating Random 0 0001 hz for 5Hz to 350Hz 6dB octave for 350Hz to 500Hz minimum 10min axis for all 3 axes Survival Random 0 015 Hz from 5Hz to 100 Hz 6dB octave from 100Hz to 137Hz 0 008 Hz from 137Hz to 350Hz ...

Страница 22: ...20 Keysight 87421 2A Power Supply Operating and Service Manual 2 Specifications ...

Страница 23: ...Keysight 87421 2A Power Supply Operating and Service Manual 3 Operating and Service Operating and Service 22 This chapter provides you the operating instructions and service information ...

Страница 24: ...unted in any orientation with user supplied hardware Fuse Replacement The power supplies have a fuse located next to the IEC appliance inlet If it is necessary to replace the fuse disconnect the power supply from both AC power and the amplifier Using a slotted screw driver open the fuse cover and replace the fuse NOTE To ensure continued compliance to product safety and EMC specifications connect ...

Страница 25: ...sight Technologies Service Center Refer to Contacting Keysight on page 4 Available Instruments and Accessories 83006A microwave system amplifier 0 01 26 5GHz 83017A microwave system amplifier 0 5 26 5GHz 83018A microwave system amplifier 2 26 5GHz 83020A microwave system power amplifier 2 26 5GHz 87415A microwave system amplifier 2 8GHz 87405C microwave system pre amplifier 0 1 18GHz 83440 60009 l...

Страница 26: ...24 Keysight 87421 2A Power Supply Operating and Service Manual 3 Operating and Service ...

Страница 27: ...This information is subject to change without notice Keysight Technologies 1992 2014 Edition 4 August 2014 87421 90001 87421 90001 www keysight com ...

Отзывы: