The 42030A is designed for use in calibrating the Keysight LCR meters which 

have four-terminal pair measurement terminals, and can be directly connected 

to the measurement terminals. The LCR meter documentation will give 

detailed information on using the 42030A.

Initial Inspection

Inspect the shipping container for damage. If the shipping container or 

cushioning material is damaged, it should be kept until the shipping contents 

have been checked for completeness and the instrument has been checked 

mechanically and electrically. The shipping contents should consist of the 

items shown in 

Table 1-1

If the shipment is incomplete, or if there is 

mechanical damage or other defects, notify your nearest Keysight 

Technologies office. If the shipping container is damaged, or the cushioning 

material shows signs of stress, notify the carrier as well as the Keysight 

Technologies office. Keep the shipping materials for the carrier's inspection. 

Your Keysight Technologies office will arrange for repair or replacement, 

without waiting for the claim settlement.

Not Assigned

Calibration Report

1

Table 1-1 

42030A Contents (Continued)

Model No. or 

Keysight Part No.

Description

Quantity

Содержание 42030A

Страница 1: ...Operation and Service Manual Keysight 42030A Four Terminal Pair Standard Resistor Set...

Страница 2: ...e under the same terms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S gov ernment customers under its stan dard commercial license which...

Страница 3: ...for Shipment 7 Keysight Packing Materials 7 Non Keysight Packing Materials 7 Specifications 8 DC Resistance 8 Operating Conditions 9 Dimensions 9 Weight 9 Supplemental Performance Characteristics 10 T...

Страница 4: ...4 Keysight 42030A Four Terminal Pair Standard Resistor Set Contents...

Страница 5: ...stability resistors and are virtually unaffected by changes in ambient temperature ensuring measurement repeatability and reliability Table 1 1 lists the 42030A contents Table 1 1 42030A Contents Mode...

Страница 6: ...een checked for completeness and the instrument has been checked mechanically and electrically The shipping contents should consist of the items shown in Table 1 1 If the shipment is incomplete or if...

Страница 7: ...l serial number Non Keysight Packing Materials The following general instructions should be used for re packing with commercially available packing materials 1 If shipping to Keysight Technologies off...

Страница 8: ...the factory it meets the specifications listed in this section DC Resistance Table 1 2 lists the nominal DC resistance for each resistance module of the 42030A Table 1 2 DC Resistance Model Number DC...

Страница 9: ...onmental conditions listed in Table 1 3 Dimensions Table 1 4 shows the 42030A dimensions Weight Table 1 5 shows the 42030A weight Table 1 3 Operating Conditions Temperature 23 C 5 C Relative Humidity...

Страница 10: ...e Conditions The 42030A must be stored or shipped under the ambient environmental conditions listed in Table 1 7 Table 1 6 DC Resistance Temperature Coefficient and Stability Model Number Nominal Valu...

Страница 11: ...The 42030A is calibrated in the parameters given in Table 2 1 with the calibration uncertainties given in Table 2 2 through Table 2 7 and equipped with a calibration report when shipped from the facto...

Страница 12: ...036A 100 0 02 42037A 1 k 0 02 42038A 10 k 0 02 42039A 100 k 0 02 Table 2 3 42035A 10 Resistor AC Calibration Uncertainty Frequency Calibration Uncertainty Series Resistance Reactance 1 MHz 0 12 0 010...

Страница 13: ...0 1 5 S 4 MHz 0 15 2 0 S 5 MHz 0 15 3 0 S 10 MHz 0 4 5 S 13 MHz 0 6 8 S Table 2 6 42038A 10 k Resistor AC Calibration Uncertainty Frequency Calibration Uncertainty Parallel Resistance Susceptance 100...

Страница 14: ...s calibration laboratories satisfy all of these calibration uncertainties For complete information on calibration contact your nearest Keysight Technologies sales and service office Calibration Interv...

Страница 15: ...This information is subject to change without notice Keysight Technologies 1992 2019 Edition 3 August 28 2019 42030 90001 42030 90001 www keysight com...

Отзывы: