background image

4

Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide

Features, Mainframe

Built-in 15 inch color touch screen with 1024 x 768 resolution

Removable hard drive

10/100/1000 Base-T LAN port

USB 2.0 ports (six total, two on front, four on back)

One PCI expansion slot

One PCI Express x1 expansion slot

Windows 10 installation 

Windows 10 support has been added to the 16860-series logic analyzers and these 

are now shipped from the factory with Windows 10 operating system preinstalled. 

Earlier, Windows 7 operating system was preinstalled on these logic analyzers. 

Keysight Logic and Protocol Analyzer

 application which takes the complexity out of 

making logic analyzer measurements. You can perform all operations directly from 

one window.

Supplied Accessories

USB mouse

USB  keyboard

Accessory pouch and power cord
Snap the accessories pouch to the top of the 16860 series logic analyzer. Use it to 

store probe leads, accessories, or manuals. Use the tie-down straps under the flap to 

conveniently hold pod cables not in use or during transport.

Optional Accessories

Probes

Front Panel

Refer to the online help in the logic and protocol analyzer software for information on 

using the analyzer.

Rear Panel

Before you turn on the system, connect your mouse and keyboard to the 16860 Series 

logic analyzer rear panel. 

16860-Series Logic Analyzer Dimensions

All dimensions given below are in Millimeters (mm). 

Содержание 16861A

Страница 1: ...Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide...

Страница 2: ...embod ied in its End User License Agreement EULA a copy of which can be found at http www key sight com find sweula The license set forth in the EULA represents the exclusive authority by which the U...

Страница 3: ...ble 350 MHz or 700 MHz maximum state clock rate depending on state speed option software upgradeable Full Channel Timing Mode at 2 5 GHz sampling with 12 5 GHz Timing Zoom Half Channel Timing Mode at...

Страница 4: ...ol Analyzer application which takes the complexity out of making logic analyzer measurements You can perform all operations directly from one window Supplied Accessories USB mouse USB keyboard Accesso...

Страница 5: ...Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 5...

Страница 6: ...rst time 2 Getting Started with the Logic Analyzer This chapter describes some basic features of the logic analyzer and tells you where to find more information on using the logic analyzer 3 Updating...

Страница 7: ...tion 13 First Time Set Up On 16860 Series Logic Analyzers 14 Additional First Time Setup Steps 16 Establishing an Administrator Account recommended for standalone and networked instruments 16 Protecti...

Страница 8: ...Windows Firewall Settings 33 To give other applications ports access through the firewall 33 To restore the logic analyzer firewall defaults 33 Software Installation and Upgrades 35 Keysight Logic an...

Страница 9: ...Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 9 Contents To clean the instrument 54 Safety Symbols 55 Index...

Страница 10: ...10 Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide Contents...

Страница 11: ...Portable Logic Analyzers Installation Quick Start Guide 1 First Time Set Up Proper Cooling 12 First Time Set Up Considerations 13 First Time Set Up On 16860 Series Logic Analyzers 14 Additional First...

Страница 12: ...OTE This instrument requires 100 120VAC 50 60 400Hz 100 240VAC 50 60Hz mains capable of supplying 325 watts Do not apply more than 25 volts to any Probe Adapter signal line Do not apply more than 5 5...

Страница 13: ...Microsoft Work group model or Microsoft Domain model In order for your instrument to perform tasks over the network print transfer files etc your instrument must be configured appropriately for the ne...

Страница 14: ...on a 16860 Series Logic Analyzer with Windows 10 Installation Configuration Task Logic Analyzer Usage Standalone No LAN Workgroup Domain Protect your instrument s PC N A Turn on Automatic Updates Tur...

Страница 15: ...t through a modem directly connected to the logic analyzer N A Register with Microsoft The 16860 series of Logic Analyzers have the Windows 10 operating system already enabled to run This registration...

Страница 16: ...count for your logic analyzer You have to be logged in to the Administrator account to do the following Install most software applies whether the instrument is networked or standalone Change the workg...

Страница 17: ...Guide 2 Getting Started with the Logic Analyzer Probing 18 Making a Measurement 19 Snap to Edge Markers 21 Left Click Menus 22 Tree Structure Bus Signal Names 22 Offline Analysis 23 Marker Overview 2...

Страница 18: ...ake it easy to connect your Keysight logic analyzer to your system under test For more information on Keysight probes See the quick reference card that came with your logic analyzer for an overview of...

Страница 19: ...Analyzers Installation Quick Start Guide 19 Getting Started with the Logic Analyzer 2 Making a Measurement 1 Start up the logic analyzer connect to your target system and select Setup Bus Signal 2 As...

Страница 20: ...20 Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 2 Getting Started with the Logic Analyzer 3 Enter a trigger value in the Waveform View 4 Acquire and view data...

Страница 21: ...c Analyzers Installation Quick Start Guide 21 Getting Started with the Logic Analyzer 2 Snap to Edge Markers You can set the markers to jump to the nearest edge of a waveform A yellow target will show...

Страница 22: ...ion Quick Start Guide 2 Getting Started with the Logic Analyzer Left Click Menus Drag a box around parts of the data When you release the mouse button a menu appears Tree Structure Bus Signal Names Sh...

Страница 23: ...r 1 Follow the instructions in Software Installation and Upgrades on page 35 to load the 16860 Series logic analyzer software on your PC 2 Acquire a trace with the logic analyzer 3 Save a configuratio...

Страница 24: ...24 Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 2 Getting Started with the Logic Analyzer Tool Tips Pause the cursor over a tool Icon and a Tool Tip Window will appear...

Страница 25: ...Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 25 Getting Started with the Logic Analyzer 2 Trigger History Save and recall trigger settings...

Страница 26: ...on until the power button is pressed Using a Short Press of the Power Button Pressing the power button on the logic analyzer for a short time less than 2 seconds Closes all programs that are running...

Страница 27: ...off and then plugged back in the system will not power on until the power button is pressed Unplugging the Power Cord or Power Loss The main power cord is to be used as the system disconnecting devic...

Страница 28: ...ltage input Ensure that the supply voltage is within the specified range and voltage fluctuations do not to exceed 10 percent of the nominal supply voltage CAUTION Do not apply more than 5 5 volts to...

Страница 29: ...nalyzers Installation Quick Start Guide 29 Getting Started with the Logic Analyzer 2 More specifications and characteristics for your instrument and measurement modules are in the on line help To find...

Страница 30: ...30 Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 2 Getting Started with the Logic Analyzer 2 Click the Logic Analyzer Specifications and Characteristics help book...

Страница 31: ...ht 16860 Series Portable Logic Analyzers Installation Quick Start Guide 3 Updating the Logic Analyzer Changing Network Settings 32 Changing Windows Firewall Settings 33 Software Installation and Upgra...

Страница 32: ...on you want to change and then set the properties of this connection For more information on changing network settings refer to the Windows 7 online help On Windows 10 To make network changes after th...

Страница 33: ...eatures is displayed If the required program or service is listed check its box to enable it otherwise click Allow another program to give unlisted programs permission to penetrate the firewall Refer...

Страница 34: ...er HTTP port The logic analyzer firewall defaults also enable the following ICMP Internet Control Message Protocol settings Allow incoming echo request Allow outgoing destination unreachable Allow out...

Страница 35: ...lyzer software or to install this software onto your PC for offline processing Download the Logic and Protocol Analyzer software from http www keysight com find lpa sw download and then install the so...

Страница 36: ...36 Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 3 Updating the Logic Analyzer...

Страница 37: ...lf Tests 38 If the logic analyzer powers itself down 40 If the Power LEDs do not come on 40 If you get a registry error and the system won t boot 40 If there are network connection problems 41 If ther...

Страница 38: ...Analyzers Installation Quick Start Guide 4 Solving Problems Running Self Tests 1 In the Keysight Logic and Protocol Analyzer application click Help Self Test 2 In the Analysis System Self Test dialog...

Страница 39: ...Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 39 Solving Problems 4...

Страница 40: ...ly for example with a long press of the power button or a power loss Windows may not flush all system information to disk and is vulnerable to problems When you power back on you may get a Registry Er...

Страница 41: ...to use remote connections Allow incoming echo requests Allow outgoing destination unreachable Allow outgoing time exceeded See To restore the logic analyzer firewall defaults on page 33 The link acti...

Страница 42: ...problems with the right click functionality on the touch screen If the accuracy of touch locations is off You may be able to calibrate the touch screen to fix the problem by following the procedures...

Страница 43: ...oints is set to 4 and the Inset is set at 20 0 4 Click Begin Calibration 5 If you want to enable the right click functionality on the touch screen select the Click Settings tab and then select the Ena...

Страница 44: ...Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 4 Solving Problems If calibrating the touch screen doesn t fix the problem see Contacting Keysight Service Support on page...

Страница 45: ...covery process on the hard drive SSD of the system This recovery process uses the hidden partition on the hard drive to restore the hard disk drive back to its original state in which it was shipped W...

Страница 46: ...ing system This is the normal startup of the system Keysight Recovery system You should select this option when you want to restore repair your Logic Analyzer software by running the Keysight recovery...

Страница 47: ...y system prompt on completion of Check Disk 2 to restore your Logic Analyzer software back to its original state in which it was shipped 3 to view a document that provides information on the recovery...

Страница 48: ...If the recovery process is able to restore the system software successfully then the following screen is displayed 5 Click OK to proceed You Logic Analysis system now reboots to Windows 10 6 The Windo...

Страница 49: ...eysight com find contactus NOTE There are situations when you are not able to run the recovery process for instance when the hard disk drive of your system fails or when running the recovery process d...

Страница 50: ...50 Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 4 Solving Problems...

Страница 51: ...ordance with IEC Publication 1010 Safety Requirements for Measuring Apparatus and has been supplied in a safe condition This is a Safety Class I instrument provided with terminal for protective earthi...

Страница 52: ...be connected to the earth terminal of the power source Whenever it is likely that the ground protection is impaired you must make the instrument inoperative and secure it against any unintended operat...

Страница 53: ...a system the safety of the system is the responsibility of the system installer If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be...

Страница 54: ...2 Clean the external surfaces of the instrument with a soft cloth dampened with water 3 Make sure that the instrument is completely dry before reconnecting it to a power source WARNING To prevent an e...

Страница 55: ...s under the terms of the Radio Communication Act of 1992 CE compliance marking to the EU Safety and EMC Directives ISM GRP 1A classification according to the international EMC standard ICES NMB 001 co...

Страница 56: ...ategory With reference to the equipment types in the WEEE Directive Annex I this product is classed as a Monitoring and Control instrumentation product Do not dispose in domestic household waste To re...

Страница 57: ...ssemblers 35 K Keysight web service support 49 L LEDs 40 N network adding logic analyzer 13 connection decision 13 debugging 41 network connection problems 41 network settings 32 O optional tools 35 R...

Страница 58: ...58 Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide Index...

Страница 59: ...Keysight 16860 Series Portable Logic Analyzers Installation Quick Start Guide 59...

Страница 60: ...This information is subject to change without notice Keysight Technologies 2017 Printed in Malaysia Second edition July 2017 16860 97003 www keysight com...

Отзывы: