background image

Keysight 11636A Operating and Service Manual

3

Safety Symbols

The following symbols on the instrument and in the documentation indicate precautions which 

must be taken to maintain safe operation of the instrument.

Regulatory Markings

When you see this symbol on your instrument, 

you should refer to the instrument’s
instruction manual for important information.

This symbol indicates hazardous voltages.

The laser radiation symbol is marked on products 

that have a laser output.

This symbol indicates that the instrument 

requires alternating current (ac) input.

This symbol indicates that the power line switch 

is ON.

This symbol indicates that the power line switch 

is OFF or in STANDBY position.

The CE mark is a registered trademark of the 

European Community. This CE mark shows that 

the product complies with all the relevant 

European Legal Directives.

The CSA mark is a registered trademark of the 

Canadian Standards Association.

This text indicates that the instrument is an 

Industrial Scientific and Medical Group 1 Class A 

product (CISPER 11, Clause 4).

Содержание 11636A

Страница 1: ...Keysight 11636A 50 Ohm Type N Power Divider DC to 18 GHz Operating and Service Manual ...

Страница 2: ...e rights customarily provided to the public to use modify reproduce release perform dis play or disclose commercial computer soft ware or commercial computer software documentation No additional government requirements beyond those set forth in the EULA shall apply except to the extent that those terms rights or licenses are explicitly required from all providers of commercial computer software pu...

Страница 3: ...ymbol is marked on products that have a laser output This symbol indicates that the instrument requires alternating current ac input This symbol indicates that the power line switch is ON This symbol indicates that the power line switch is OFF or in STANDBY position The CE mark is a registered trademark of the European Community This CE mark shows that the product complies with all the relevant Eu...

Страница 4: ...itoring and Control Instrument product The affixed product label is as shown below Do not dispose in domestic household waste To return this unwanted instrument contact your nearest Keysight Service Center or visit http about keysight com en companyinfo environment takeback shtml for more information Sales and Technical Support To contact Keysight for sales and technical support refer to the suppo...

Страница 5: ...tory Markings 3 Waste Electrical and Electronic Equipment WEEE Directive 4 Product category 4 Sales and Technical Support 4 List of Figures 7 List of Tables 9 Introduction 11 Specifications 11 Adjustments 12 Service 12 Equipment and Supplies 13 Cleaning Connectors 13 Contacting Keysight 14 ...

Страница 6: ...6 Keysight 11636A Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...

Страница 7: ...Keysight 11636A Operating and Service Manual 7 List of Figures Figure 1 Tracking between output ports 11 Figure 2 Dimensions 12 ...

Страница 8: ...8 Keysight 11636A Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...

Страница 9: ...Keysight 11636A Operating and Service Manual 9 List of Tables Table 1 Type N adapters available from Keysight Technologies 13 Table 2 Equipment and supplies 13 ...

Страница 10: ...10 Keysight 11636A Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...

Страница 11: ... maintain concentricity Any port may be used as an input as the 11636A provides a symmetrical 6 dB division The 11636A can be used as a power combiner When signals are input at two of the ports the sum of the two appears at the third Specifications Maximum input power 1 0 W CW 1 kW peak 5 msec pulse width Frequency range DC to 18 GHz Input output SWR DC to 10 0 GHz 1 25 10 0 GHz to 26 5 GHz 1 35 T...

Страница 12: ... split into three identical channels A malfunction will usually occur in only one channel and can be verified by moving the connection to another channel of the divider An ohmmeter can be used to check the continuity of the inner conductor connections The resistance from either output center conductor to the input center conductor should be 33 3 ohms 2 ohms There are no replaceable components for ...

Страница 13: ...mber 08510 90064 at www keysight com Table 1 Type N adapters available from Keysight Technologies Description Part number Type N m to 3 5 mm m 1250 1743 Type N m to 3 5 mm f 1250 1744 Type N f to 3 5 mm f 1250 1745 Type N f to 3 5 mm m 1250 1750 Type N m to 2 4 mm m 11903A Type N f to 2 4 mm f 11903B Type N f to 2 4 mm m 11903C Type N m to 2 4 mm f 11903D Table 2 Equipment and supplies Item Part n...

Страница 14: ...nding a local Keysight office are available on the Web at www keysight com find assist NOTE In any correspondence or telephone conversation refer to the Keysight product by its model number and full serial number With this information the Keysight representative can determine whether your product is still within its warranty period ...

Страница 15: ...n is subject to change without notice Always refer to the Keysight website for the latest revision Keysight Technologies 2014 2019 Edition 2 January 17 2019 Printed in Malaysia 11636 90004 11636 90004 www keysight com ...

Отзывы: