1
Keysight ZA0060A Quick Start Guide
40
Test Steps and Description
Active Scan
This step must be a child step of
. This step acquires the
Bluetooth
®
5
Signaling PER of the device according to the settings below.
Basic and Advanced Settings:
– Packet Count: Set number of packets sent to the DUT from 34999B module to calculate PER.
– PER Limit: Set the upper limit of PER. Results that exceed this PER limit will be reported as Fail.
– Repeat: Set the number of PER readings to be acquired within the test.
– Early Fail Count: Set the maximum number of consecutive failed packet allowed before reporting
error.
– Scan Delay from Measure Advertising Interval Step: There are two options for this setting.
– Select the check box to use the Interval settings in
test step.
– Clear the check box and enter the desired value in the Custom Scan Delay option (default value is
set at 170 milliseconds).
When a PER reading exceeds the limit, the test step to report ‘Fail’ verdict regardless of the number of
repeats. This test step will also report the Scan Response Bytes and Scan Data Bytes described below.
– Scan Response Bytes: Total bytes of device's scan data.
– Scan Data Bytes: Content of device's scan data.