Specifications and Characteristics - RP793xA, RP794xA
Specifications - RP793xA, RP794xA
Supplemental Characteristics - RP793xA, RP794xA
Inductive Load Boundary for Current Priority Mode
Capacitive Load Boundary for Voltage Priority Mode
Measurement Accuracy and Resolution
Specifications - RP793xA, RP794xA
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to
40°C after a 30-minute warm-up period. Specifications apply at the output terminals, with the sense
terminals connected to the output terminals (local sensing).
Specification
RP7931A,
RP7941A
RP7932A,
RP7942A
RP7933A,
RP7943A
RP7935A,
RP7945A
RP7936A,
RP7946A
DC Ratings
Voltage source:
Current source and sink:
Power:
0 to 20 V
0 to ±400 A
0 to ±5 kW
0 to 80 V
0 to ±125 A
0 to ±5 kW
0 to 20 V
0 to ±800 A
0 to ±10 kW
0 to 80 V
0 to ±250 A
0 to ±10 kW
0 to 160 V
0 to ±125 A
0 to ±10 kW
Output ripple & noise
CV peak-to-peak:1
CV rms:2
30 mV
3 mV
80 mV
8 mV
30 mV
3 mV
80 mV
8 mV
200 mV
20 mV
Load regulation
Voltage:
Current:
1 mV
25 mA
3 mV
13 mA
1 mV
50 mA
3 mV
25 mA
6 mV
13 mA
Voltage programming &
measurement accuracy3
0.02% + 2 mV
0.02% + 8 mV
0.02% + 2 mV
0.02% + 8 mV
0.02% + 16 mV
Current programming &
measurement accuracy:3
0.04% + 45 mA
0.03% + 13 mA
0.04% + 90 mA
0.03% + 25 mA
0.03% + 13 mA
Transient response4
Recovery Time:
Settling band:
300 µs
0.2 V
300 µs
0.8 V
300 µs
0.2 V
300 µs
0.8 V
300 µs
1.6 V
1 From 20 Hz to 20 MHz (-3dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded
2 From 20 Hz to 10 MHz (-3dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded
3 Percent of value + offset; at 25°C ±5°C after a 30 minute warm-up; measurement NPLC=1; valid for 1 year, see
with a load lead voltage drop of up to 1V per lead - see
for additional information about load lead voltage drop
4 Time to recover to within the settling band following a step change from 40% to 90% of full load with a 35 μs current rise time
Keysight RP7900 Series Operating and Service Guide
35
1 Quick Reference
Содержание RP7900 Series
Страница 1: ...Keysight Regenerative Power System RP7900 Series Operating and Service Guide ...
Страница 2: ......
Страница 51: ...Dimensions RP793xA and RP794xA Keysight RP7900 Series Operating and Service Guide 51 1 Quick Reference ...
Страница 60: ...Dimensions RP795xA and RP796xA 1 Quick Reference 60 Keysight RP7900 Series Operating and Service Guide ...
Страница 100: ......
Страница 244: ...Status Diagram 5 SCPI Programming Reference 244 Keysight RP7900 Series Operating and Service Guide ...
Страница 246: ...Trigger Diagram 5 SCPI Programming Reference 246 Keysight RP7900 Series Operating and Service Guide ...
Страница 262: ......
Страница 314: ......