Compensation for Current Priority Mode 0 (160 V units)
Compensation for Current Priority Mode 1 (160 V units)
160 V, 10 kW unit
160 V, 10 kW unit
Capacitive Load Boundary for Voltage Priority Mode
The following figures show the boundary limitations for capacitive loads with equivalent series
resistance for voltage priority mode. Operation below the marginal stability lines with the
bandwidth settings may result in output instability. Conditions with and without load
leads illustrate the additional effects of inductance on CV mode stability. There are no absolute limits
for DUT capacitance, as the stability is also a function of ESR. Refer to
for details.