Configure your Keysight N934xC* Handheld Spectrum Analyzer (HSA)

This configuration guide will help you determine which performance options, measurement application software, accessories, and 
services to include with your new Keysight Technologies, Inc. N9344C, N9343C and N9342C HSAs, or to add as upgrades to an 
existing HSA. This step-by-step process will help you configure your N9344C/N9343C/N9342C HSAs. Capabilities that are listed as 
standard come with the instrument at no additional charge. Tailor the performance, and service packages to meet your requirements. 
Ordering optional capabilities at the time of purchase provides the lowest overall cost. 

For performance information, refer to the N9344C/N9343C/N9342C Handheld Spectrum Analyzer Data Sheets. See literature 
numbers in the Additional Resources section on page 7.

Description

Option number

Additional information

Step 1. Select maximum frequency range (frequency range not upgradable)

Frequency range, 1 MHz to 20 GHz

N9344C

Tunable to 9 kHz

Frequency range, 1 MHz to 13.6 GHz

N9343C

Tunable to 9 kHz

Frequency range, 100 kHz to 7 GHz

N9342C

Tunable to 9 kHz

Step 2. Add a preamplifier

Preamplifier, 1 MHz to 20 GHz

N9344C-P20

For N9344C

Preamplifier, 1 MHz to 13.6 GHz

N9343C-P13

For N9343C 

Preamplifier, 100 kHz to 7 GHz

N9342C-PA7

For N9342C 

Step 3. Add a tracking generator

Tracking generator, 5 MHz to 7 GHz

N934xC-TG7

Output level –20 dBm to 0 dBm, 1 dB step

Step 4. Add a cable and antenna tester

Cable and antenna test, 5 MHz to 7 GHz

N9342C-CA7

 

Exclusive to the N9342C HSA.

 

Offers return loss, VSWR, cable loss, and distance-to-fault (DTF). 

 

Requires the tracking generator module (Option TG7).

 

Requires N9311X-201 precision mechanical calibrator (3-in-1 OSL).

 

Recommended accessories include N9311X-585 phase stable cable type N(m) 

to DIN(f),  N9311X-586 phase stable cable type N(m) to N(f), and N9311X-547 
adapter type N(m) to DIN(f).

Step 5. Add a GPS receiver

GPS receiver, with built-in antenna

N934xC-GPS

Provides information on longitude, latitude, and altitude.
An optional external antenna N934xC-GPA can be ordered.

Step 6. Add optional measurement features

Spectrum monitor 

N934xC-SIM

Adds spectrogram view, record, playback, and audio alert. Great tool for spectrum 
monitoring and interference analyzing.

Channel scanner

N934xC-SCN  

Allows the user to easily measure channel power of multiple channels and export data 
to mapping applications like Google Earth and MapInfo.

Task planner

N934xC-TPN

Reduces test setup time by 95%, delivers test automation and consistency, and 
makes it easy to capture test results, generate reports, and share task plans with 
others. Find more information at 

www.keysight.com/find/taskplanner

.

U2000 Series USB power sensor support

N934xC-PWM

Requires the Keysight U2000 Series USB power sensor.

U2020/2040 X-Series USB peak and 
average power sensor support

N934xC-PWP

Requires the Keysight U2020/2040 X-Series USB peak and average power sensor.

Security features

N934xC-SEC

Low-level and non-recoverable formatting of user memory and  
USB/LAN port control

EMI filters and quasi-peak detector

N934xC-EMC

Provides CISPR compliant resolution bandwidth (200 Hz, 9 kHz, 120 kHz and 1 MHz) 
and quasi-peak detector for basic EMI precompliance test.

* * Throughout this document “N934xC” refers to N9344C, N9343C, and N9342C.

02 | Keysight | N9342-44C Handheld Spectrum Analyzer (HSA) - Configuration Guide

Содержание N9344C

Страница 1: ...Keysight Technologies N9344C N9343C N9342C Handheld Spectrum Analyzer HSA Configuration Guide ...

Страница 2: ...stance to fault DTF Requires the tracking generator module Option TG7 Requires N9311X 201 precision mechanical calibrator 3 in 1 OSL Recommended accessories include N9311X 585 phase stable cable type N m to DIN f N9311X 586 phase stable cable type N m to N f and N9311X 547 adapter type N m to DIN f Step 5 Add a GPS receiver GPS receiver with built in antenna N934xC GPS Provides information on long...

Страница 3: ... 1DN Provides DC power supply and power charging Hard transit case N934xC 1TC Adaptor 50 to 75 Ω N934xC TAD Type N m 50 Ω to type N f 75 Ω Ergonomic soft carrying case with backpack and shoulder strap N934xC SCC External GPS antenna N934xC GPA SMA M connector Calibrator N9311x 201 Precision mechanical calibrator 3 in 1 OSL DC to 7 GHz N m Antenna N9311x 500 70 to 1000 MHz 65 g 180 degree tilt angl...

Страница 4: ...ter N9311x 546 Type N f to Type N f DC to 18 GHz Adapter N9311x 547 Type N m to DIN f DC to 7 5 GHz Cable N9311x 580 Phase stable 1 5 m N m to N m Cable N9311x 581 Phase stable 3 m N m to N m Cable N9311x 582 1 5 m SMA m to SMA m Cable N9311x 583 1 5 m BNC m to BNC m Cable N9311x 585 Phase stable 1 5 m N m to DIN f Cable N9311x 586 Phase stable 1 5 m N m to N f Attenuator N9311x 560 40 dB N m to N...

Страница 5: ...g applications like Google Earth and MapInfo Task planner N934xCK TPN Reduces test setup time by 95 delivers test automation and consistency and makes it easy to captures test results generate reports and share task plans with others Find more information at www keysight com find taskplanner U2000 Series USB power sensor support N934xCK PWM Requires the Keysight U2000 Series USB power sensor U2020...

Страница 6: ... Additional information Instrument upgrades Cable and antenna test 5 MHz to 7 GHz N9342CK CA7 or N9342CK CAU Exclusive to the N9342C HSA Requires the tracking generator module Option TG7 If Option TG7 is not installed on the N9342C please order both N9342CK TG7 and N9342CK CA7 Otherwise please check the TG module S N If the TG module S N starts with N934263004 please order N9342CK CA7 If the TG mo...

Страница 7: ... with battery 3 6 kg 7 9 Ibs Hard transit case weight and dimensions Dimensions W x H x D 560 mm x 460 mm x 270 mm Weight empty 7 7 kg 16 9 lbs Standard shipped items N934xC HSA RoHS addendum USB cable Battery Li Ion Screwdriver Help kit CD Ear phone AC DC power supply Quick start tutorial Other Information Additional Resources Related Keysight literature Publication Publication number Publication...

Страница 8: ...le can help you reach your next breakthrough We are unlocking the future of technology From Hewlett Packard to Agilent to Keysight For more information on Keysight Technologies products applications or services please contact your local Keysight office The complete list is available at www keysight com find contactus Americas Canada 877 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 Unite...

Отзывы: