c. Locate the two cable assembly N9000-20108 and N9000-20132 in the upgrade kit. Connect 

N9000-20108 from AUX IF Assembly J2 connector (

Figure 6

) to RF Board J336 connector 

(

Figure 7

). Connect N9000-20132 from AUX IF Assembly J3 connector to AUX IF Out 

connector (W5) of the rear panel (

Figure 3

). Use 9/16-inch nut driver if necessary.

Figure 7 

Cable Connection

7. Re-install the DIF board (reconnect W4 and W6), rear panel, top brace, reference bracket and 

instrument outer case. Avoid pinching cables when installing the top brace.

 

J336

Содержание N9000A

Страница 1: ...ce This document contains references to Agilent Please note that Agilent s Test and Measurement business has become Keysight Technologies For more information go to www keysight com Installation Note Part Number N9000 90034 Printed in USA July 2014 N9000 90034 N9000 90034 ...

Страница 2: ...o this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Keysight Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Copyright 2012 2014 Keysight Technologies Inc ...

Страница 3: ... this document will guide you through the following steps which will need to be followed closely and performed in the order defined 1 Pre upgrade Status Check 2 Hardware Installation 3 Update the Instrument Firmware 4 Install the License File 5 Installation Verification Products Affected CXA N9000A Serial Numbers CXA To Be Performed By X Agilent Service Center X Personnel Qualified by Agilent X Cu...

Страница 4: ...A signal analyzer Contents Tools Required Torx Driver T 10 Torx Driver T 20 9 16 inch nut driver USB storage device 2GB free memory Quantity Description Agilent Part Number 1 AUX IF Assembly N9000 60414 1 Ribbon Cable E4410 60162 1 Cable Assembly DIF Rear Panel Aux IF Out N9000 20108 1 Cable Assembly RF DIF N9000 20132 3 Screw M3 0 5 8 mm 0515 0372 1 Entitlement Certificate 5964 5178 1 Entitlement...

Страница 5: ...ther repair the instrument prior to proceeding with this upgrade or make detailed notes of the instrument status in the space provided below and address them once this upgrade has been completed if they continue to be present ______________________________________________________________________________ ____________________________________________________________________________ __________________...

Страница 6: ... case of the instrument a Refer to Figure 1 Using the T 20 driver remove the four screws two on each side 1 that attach the handle strap 2 on each side of the instrument b Using the T 20 driver remove the four screws including washers 3 that hold the rear feet 4 in place c Pull the instrument cover 5 off towards the rear of the instrument Figure 1 Standard Instrument Outer Case Removal 3 Remove th...

Страница 7: ...To Remove the reference bracket 2 use the T 10 driver to remove the six screws 5 including two at the rear panel attaching the reference bracket to the instrument and the four screws 4 attaching the top brace to the reference bracket Figure 2 Top Brace and Reference Bracket Removal ...

Страница 8: ...el Figure 3 Rear Panel Removal a Remove the twenty screws 2 attaching the rear panel 1 to the chassis and to the reference bracket The rear panel can now be removed b If W5 is installed on this instrument remove W5 at the rear panel using a 9 16 inch nut driver and disconnect it from the RF assembly 1 2 W1 W4 2 2 2 W5 W7 ...

Страница 9: ...eband IF Output Installation Kit 5 Refer to Figure 4 to remove the DIF board Figure 4 DIF Board Removal a Remove cable W4 and W6 from the bottom of the DIF board b The DIF board can be removed from the chassis by pulling straight out the back W4 W6 ...

Страница 10: ...de kit and install it on the upper side of the DIF board Connect the E4410 60162 ribbon cable from DIF board to AUX IF assembly Figure 5 AUX IF Assembly Installation A b Locate the three 0515 0372 screws in the upgrade kit Refer to Figure 6 tighten the screws from the bottom side of the DIF board to attach the AUX IF assembly on the upper side of the DIF board Figure 6 AUX IF Assembly Installation...

Страница 11: ...y J2 connector Figure 6 to RF Board J336 connector Figure 7 Connect N9000 20132 from AUX IF Assembly J3 connector to AUX IF Out connector W5 of the rear panel Figure 3 Use 9 16 inch nut driver if necessary Figure 7 Cable Connection 7 Re install the DIF board reconnect W4 and W6 rear panel top brace reference bracket and instrument outer case Avoid pinching cables when installing the top brace J336...

Страница 12: ... find Xseries_software 4 Install the License File 1 Located Option Upgrade Entitlement Certificate in the kit and follow the directions to redeem it You will receive and email with an attached license file 2 Located the USB storage device Perform a virus scan on this device before use Save the license file to the root directory of the USB storage device 3 Connect the USB storage device to the sign...

Страница 13: ...ate on N9000A signal analyzer a Press Input Output RF Calibrator 50 MHz b Press Amplitude Attenuation 0 dB 3 Connect a spectrum analyzer to the AUX IF OUT connector at the rear panel Verify if there is a signal at frequency point 322 5 MHz and with amplitude from 30 to 15 dBm End of Installation For assistance contact your nearest Agilent Technologies Sales and Service Office To find your local Ag...

Страница 14: ...14 Installation Note N9000 90034 Option CR3 Wideband IF Output Installation Kit ...

Отзывы: