Keysight N5990A MIPI M-PHY Receiver Test User Guide
257
PWM Tests
7
Procedure
The data generator sends Burst-mode CJTPAT signaling with nominal
amplitude settings while the DUT is configured for Terminated-mode or
Non-Terminated-mode depending on the test case.
The TOL
PWM-RX
is the ratio of the PWM Receive Bit Duration (T
PWM-RX
)
and the average of N PWM receive bit durations in PWM-MODE. The
TOL
PWM-RX
is tested for the conformance limit values (0.82/1.18) and for
the given Additional Steps. At each step, the BER is measured and
compared with the Target BER to consider the pass/fail result.
This test is performed at each selected lane and PWM gear.
Connection Diagram
Refer to the connection diagrams shown in the Connection Diagram
section of the Test 2.1.1- HS-RX Differential Input Voltage Amplitude Test
test.
Parameters
The parameters (in Expert Mode), for this tolerance test are as follows:
• CDR Loop Bandwidth (if CDR is selected in the Special Parameter
dialog, see
)
• CDR Peaking (if CDR is selected in the Special Parameter dialog, see
• CDR Transition Density (if CDR is selected in the Special Parameter
dialog, see
)
• CDR Loop Order (if CDR is selected in the Special Parameter dialog,
see
• Target BER
• IBerReader Init Mode
• Test Sequence
• Re-Init sequence after Reset DUT
• Lane Under Test Termination Mode
• Min Tested
• Max Tested
• Additional Steps
These parameters are listed in alphabetical order in
Содержание N5990A
Страница 1: ...User Guide Keysight N5990A MIPI M PHY Receiver Test...
Страница 17: ...Keysight N5990A MIPI M PHY Receiver Test User Guide 1 Introduction Document History 18 Overview 19...
Страница 62: ......
Страница 86: ...86 Keysight N5990A MIPI M PHY Receiver Test User Guide 4 Calibrations...
Страница 88: ...88 Keysight N5990A MIPI M PHY Receiver Test User Guide 4 Calibrations...
Страница 214: ......
Страница 234: ......
Страница 268: ......
Страница 298: ......