background image

Startup
Guide

Keysight Modular
Arbitrary Waveform Generator

Содержание M9336A

Страница 1: ...Startup Guide Keysight Modular Arbitrary Waveform Generator...

Страница 2: ...ment are furnished under a license and may be used or copied only in accordance with the terms of such license U S Government Rights The Software is commercial computer software as defined by Federal...

Страница 3: ...d to work on live circuits perform safe installations and repair products Only properly trained service personnel may perform installation and service procedures Operator is responsible to maintain sa...

Страница 4: ...ons and operating information and as shown on the instrument or test fixture panels or switching card When fuses are used in a product replace with the same type and rating for continued protection ag...

Страница 5: ...a terminal which is internally connected to the product frame or chassis This symbol indicates the instrument is sensitive to electrostatic discharge ESD ESD can damage the highly sensitive component...

Страница 6: ...6 This page has been intentionally left blank...

Страница 7: ...Practices 22 Instrument Air Flow 22 Tools Required for the Installation Procedure 23 Cable and Connector Care 23 Prepare the Instrument 23 Install the Software 24 System Requirements 24 Software Inst...

Страница 8: ...atus for M9336A P9336A AWG 38 Conduct Self Test 39 Step 5 Generate and View an Output Signal 42 Step 6 Installation is Complete 46 Application Programming Interface API Overview 46 IVI Drivers 46 LabV...

Страница 9: ...9 This page has been intentionally left blank...

Страница 10: ...ware is installed on your PC the related documents are also available in the software installation directory Startup Guide Includes procedures to help you unpack inspect install software and hardware...

Страница 11: ...includes information to help you get started with using the IVI drivers in your application development environment Default Location on 64 bit Windows system Your Drive Program Files x86 IVI Foundatio...

Страница 12: ...ht website Format PDF Security Guide Provides instructions for protecting and removing classified proprietary information stored in the AWG Default Location on 64 bit Windows system Available only on...

Страница 13: ...Magnitude EVM making it ideal for creating baseband waveforms for wireless communications radar and satellite The AWG can also be combined with a wideband I Q upconverter resulting in modulation bandw...

Страница 14: ...om Waveform Memory ranges from 1 Sa s to 1 28 GSa s on each channel Per channel control of channel skew gain and offset Model Specific Features P9336A M9336A A USB module shipped with USB chassis as a...

Страница 15: ...This page has been intentionally left blank...

Страница 16: ...en Store the module in an anti static envelope when not in use ESD Electrostatic discharge ESD can damage or destroy electronic components Use a static safe workstation to perform all work on electron...

Страница 17: ...bitrary Waveform Generator 1 M9336 90002 Keysight M9336A PXle I Q Arbitrary Waveform Generator Quick Start Flyer 1 1250 3854 Adaptor coaxial straight SMB f to SMB m 1 8120 5091 Cable coaxial SMB SMB 1...

Страница 18: ...d attach it to the malfunctioning equipment Name and address of the owner A P O box is not acceptable as a return address Description of failure or service required 4 Pack the instrument in its origin...

Страница 19: ...This page has been intentionally left blank...

Страница 20: ...Latest Documentation Step 2 Download the Latest Documentation Download the latest version of AWG Startup Guide and other documents from www keysight com find usb awg or www keysight com find M9336A A...

Страница 21: ...This page has been intentionally left blank...

Страница 22: ...tions Cooling Best Practices The following are the recommended best practices to ensure proper and safe module operating conditions Ensure that the ambient air temperature around the instrument does n...

Страница 23: ...the push on cables from the front panel connectors use the below Keysight Cable Removal Tool PN 5002 3361 The Cable Removal Tool is not provided in your Keysight module s ship kit You need to order i...

Страница 24: ...of the Keysight IO Libraries Suite is required AWG software which includes the soft front panel SFP device driver IVI NET IVI C and LabVIEW and documentation for the AWG This software is included wit...

Страница 25: ...This page has been intentionally left blank...

Страница 26: ...and multi chassis systems visit www keysight com find pxie multichassis Before Installing the Module Precautions PXIe hardware does not support hot swap changing modules while power is applied to the...

Страница 27: ...between modules changes the length of inter module cables if any and may also cause the modules to be on different chassis backplane PXI_TRIG trigger bus segments Set the fan speed switch on the rear...

Страница 28: ...establish earth ground 2 Make sure that the chassis power switch is Off 3 Before inserting a module into the chassis back the mounting screws out to ensure that there is no interference between the s...

Страница 29: ...cted to do so later in this document Embedded Controller If your configuration contains a Keysight Embedded Controller for example M9037A follow the procedure below For additional details refer to the...

Страница 30: ...57 N m 3 Connect peripherals mouse keyboard and monitor Remote Controller If your configuration contains a Keysight Cable Interface module follow the procedure below The following procedure addresses...

Страница 31: ...by the injector ejector handle and making sure the injector ejector handle is pushed down in the unlatched downward position slide the module into chassis using the slot guides top and bottom b Slidin...

Страница 32: ...ng modules from left to right according to the image below When installing the M9336A AWG 1 Hold the module by the injector ejector handle and make sure that the injector ejector handle is pushed down...

Страница 33: ...your Keysight Customer Contact Center AWG software which includes the soft front panel SFP device driver IVI NET IVI C and LabVIEW and documentation for the AWG This software is included with your shi...

Страница 34: ...Step 3B Install the M9336A PXIe Module Use Start Shut down 4 Power down the chassis 5 Power up the chassis 6 Power up the remote controller PC AWG Startup Guide 34...

Страница 35: ...This page has been intentionally left blank...

Страница 36: ...AWG To check if the AWG is visible in the Keysight Connection Expert Start Keysight Connection Expert by clicking Start All Programs Keysight Connection Expert Keysight Connection Expert If the AWG i...

Страница 37: ...Step 4 Verify Operation 37 AWG Startup Guide Keysight Connection Expert for P9336A AWG...

Страница 38: ...lue Power okay temperature okay successful PCI enumeration Solid Green The LED will go from blue to green when the IVI driver is initialized or the SFP is opened It will go from green back to blue whe...

Страница 39: ...ble below lists the status description of the LED states for the additional Power LED LED State Status Green Instrument is turned on Amber Power supply is on but the instrument is turned off OFF Power...

Страница 40: ...the Connect to Instrument dialog box close the SFP and refer to Communications After running Keysight Connection Expert you may restart the SFP 3 Check the front panel LEDs Refer to LED Status Indica...

Страница 41: ...4 Verify Operation If the Self Test fails it indicates the module is likely to need service and you must return the modules and the cables Refer to Return the Instrument for Service 41 AWG Startup Gu...

Страница 42: ...yed b Select P9336A M9336Ain the displayed list of instruments depending upon the instrument and click Connect 2 Connect a high quality SMB Female to the BNC cable between the AWG Channel Source Outpu...

Страница 43: ...Waveform drop down select a waveform that you wish to play 6 Click Initiate When you click the Initiate button waveform generation starts The Generation State status then changes from Configuration s...

Страница 44: ...e the waveform on your oscilloscope The waveform generated by the above steps is very basic You can apply other settings for example Delay offset voltage and more on the waveform as needed 7 Proceed t...

Страница 45: ...This page has been intentionally left blank...

Страница 46: ...lable for Microsoft Visual Studio s IntelliSense context linking In addition you can directly access the chm file Keysight KtMAwg Fx45 chm from this Start menu location Start All Programs Keysight Ins...

Страница 47: ...This page has been intentionally left blank...

Страница 48: ...equipment could be impaired This product must be used in a normal condition in which all means for protection are intact only The measuring terminals on this instrument are designed to be used with e...

Страница 49: ...ol before touching it or removing it from the chassis This product is designed for use in Installation Category II and Pollution Degree 2 environment For the AC DC Adapter For safety reasons only equi...

Страница 50: ...ed 10 percent of the nominal supply voltage The AC DC adapter is for indoor use only Never use a modified or damaged charger Use the original AC DC adapter ONLY The AC DC adapter is designed for use i...

Страница 51: ...This information is subject to change without notice Keysight Technologies Inc 2019 Edition 2 1 June 2019 P9336 90001 www keysight com...