Keysight Technologies M8190A Скачать руководство пользователя страница 28

2      AXIe Chassis 

28 

 

M8190A Getting Started Guide 

c.

 

When the system is first configured and started, the TCP/IP LAN 
connection will not be available. You should manually add the LAN 
instrument manually.  To do so, select LAN Instrument from the list of 
devices that can be added, at the left of the screen. While doing so, 
make sure that the firmware is running in the background. 

d.

 

Fill in the instrument's properties. The IP address of the instrument 
will be the IP address of the PC running the firmware or localhost. 

 

e.

 

Test the connection. 

f.

 

Click Accept. 

For more details, refer to online help of Keysight Connection Expert. 

 

Query 

The M8190A firmware comes up, but the M8190A SFP (Soft Front Panel) does not 
comes up.

 

Solution 

Ensure that same version of both M8190A Firmware and M8190A IVI drivers must be 
properly installed. 

 

Query 

The M8190A firmware display an error message asking for a log file.

 

Solution 

The stated folder might be a hidden one. When entering the path manually in the  

File Explorer (…

\AppData\...) it should show up. 

 

Query 

M8190A firmware upgrade is not successful.

 

Solution 

If your firmware upgrade is not successful, follow the given steps:  

1.

 

Manually uninstall the old versions of the M8190A Firmware and the  

M8190A IVI driver. 

2.

 

Now, start the fresh installation of the new M8190A firmware version. 

 

 

Query 

The AXIe chassis or a module does not power up.

 

Solution 

If the chassis or a module does not appear to power up, check the following: 

 

The circuit breakers at the rear of the chassis are set to the right, which is the 
ON position. 

 

The AC power cords are connected to a working power source. 

 

The electrical circuits are not overloaded. Check the combined power 
requirements of all equipment on the same circuit. 

 

There are no empty slots in the chassis. Leaving slots empty can overheat the 
inserted modules, causing them to shut down.

 

 

Query 

Contacting Keysight for sales, service and support.

 

Solution 

To contact Keysight for sales, service and support, go to; 

www.keysight.com/find/contactus

. 

 
 
 

Содержание M8190A

Страница 1: ...Getting Started Guide Keysight M8190A Arbitrary Waveform Generator...

Страница 2: ...HALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING USE OR PERFORMANCE OF THIS DOCUMENT OR OF ANY INFORMATION CONTAINED HEREIN SHOULD KEYSIGHT AN...

Страница 3: ...ervice Office WARNING To avoid hazardous electrical shock do not perform electrical tests when there are signs of shipping damage to any portion of the outer enclosure covers panels etc General This p...

Страница 4: ...Recycling Mark Table 2 Compliance and Environmental Information Symbol Description This product complies with the WEEE Directive 2002 96 EC marketing requirements The affixed label indicates that you...

Страница 5: ...How to Use the Instrument 22 2 6 How to Access Two M8190A Modules in a Single Chassis 24 2 7 Basic Problems 27 3 AXle Chassis 3 1 ESM Front Panel Connector 29 4 M8190A Maintenance 4 1 ESD Protection...

Страница 6: ......

Страница 7: ...nge SFDR up to 80 dBc typical Harmonic distortion HD up to 72 dBc typical Standard arbitrary waveform memory size 128 MSa per channel with Option 14B and Option 12G 64 MSa IQ sample pairs with Option...

Страница 8: ...lities AXIe chassis PCIe or USB 2 0 cable PC and M8190A AWG are ordered separately The different components come in different packages and need to be installed Please follow the instructions given in...

Страница 9: ...uct web site www keysight com find M8190A and browse the manuals under Document Library tab Additional Documents Additional documentation can be found at http www keysight com find M9502A for 2 slot c...

Страница 10: ......

Страница 11: ...higher installed on your system The Keysight IO Libraries Suite can be found on the CD that is part of shipment content or at http www keysight com find iosuite Even if a non Keysight I O library is a...

Страница 12: ...n your system 1 Double click the executable M8190_Setup exe This executable file will be available either on CD or Web See http www keysight com find M8190A The installer will first check for some pre...

Страница 13: ...ng Started Guide 13 2 The Keysight M8190A Setup will prepare the InstallShield Wizard for the installation process The following window will appear 3 Follow the onscreen instructions to begin the inst...

Страница 14: ...Started Guide 4 We recommend you to read the document to check if your hardware configuration is supported Click Next to proceed to the license agreements 5 Accept the terms of Keysight software end u...

Страница 15: ...ting Started Guide 15 6 Accept the terms of Keysight IVI driver source code license agreement terms Click Next 7 Select Yes if you want to read the post installation instructions when finished Click N...

Страница 16: ...AXIe Chassis 16 M8190A Getting Started Guide 8 Select a setup type either Complete or Custom Click Next 9 If you select Custom and click Next you can specify which optional features will be installed...

Страница 17: ...Introduction 2 M8190A Getting Started Guide 17 10 Click Install to begin installation...

Страница 18: ...2 AXIe Chassis 18 M8190A Getting Started Guide 11 The Setup Wizard will now install AgM8190 IVI Drivers...

Страница 19: ...tion 13 The following screen will appear once the Keysight M8190A software is successfully installed on your system 14 Click Finish to restart your system Do not connect the AXIe chassis to your syste...

Страница 20: ...Wait until the Access LED of the M8190A has switched from red to green 4 Switch on the PC 5 The PC should automatically recognize the instrument Check this in the device manager e g via Start Control...

Страница 21: ...software components are available as EXE files To download a software upgrade 1 Go to http www keysight com find M8190A 2 Click the Technical Support tab 3 Click Drivers Firmware Software 4 Download...

Страница 22: ...itched on before you start the PC 2 Start the firmware Start All Programs Keysight M8190 Keysight M8190 3 The user interface will display the VISA resource strings for different kinds of connection 4...

Страница 23: ...sight Connection Expert TCPIP0 localhost and control it using SCPI with e g the VISA Assistant or your own application You must start the firmware in order to send SCPI commands to the instrument The...

Страница 24: ...hassis or on a separate PC that is connected via PCIe or USB to the AXIe chassis If you have more than one module in the same chassis you must specify the firmware which module it should control Also...

Страница 25: ...tarted Guide 25 You can also copy an existing firmware shortcut present on the desktop and then paste it Paste shortcut two times Step 2 Now open the M8190A firmware and identify the VISA Resource Str...

Страница 26: ...rameters to the target string Copy the Visa Resource String for first firmware and add it to the target field and press OK Step 4 Similarly copy the Visa Resource String for second firmware and add it...

Страница 27: ...controller automatically starts after the chassis power is stable Query The instrument is not listed in Keysight Connection Expert s Instruments View Solution 1 See if the instrument is listed in Key...

Страница 28: ...ution The stated folder might be a hidden one When entering the path manually in the File Explorer AppData it should show up Query M8190A firmware upgrade is not successful Solution If your firmware u...

Страница 29: ...s in combination with the M8190A The detailed documentation for the AXIe chassis can be found at http www keysight com find M9505A for 5 slot chassis http www keysight com find M9502A for 2 slot chass...

Страница 30: ...ultiframe Output 5 Trigger In External Trigger connections The Trigger In of the AXIe ESM cannot be used to trigger the M8190A The M8190A has its own Trigger In The Trigger Out of the AXIe ESM cannot...

Страница 31: ...Electrostatic discharge ESD can damage the circuits of the M8190A Avoid applying static discharges to the front panel connectors Before connecting any coaxial cable to the connectors momentarily short...

Страница 32: ...4 4 Battery The M8190A does not have a battery 4 5 Operating Environment Storage Temperature 40 C to 70 C Operating Temperature 0 C to 40 C Humidity 95 R H at 40 C Altitude Up to 2000 m Installation C...

Страница 33: ...rating temperature 0 C to 40 C Storage temperature 40 C to 70 C Operating humidity 5 to 80 relative humidity non condensing Operating altitude up to 2000 m Safety designed to IEC 61010 1 UL 61010 1 CA...

Страница 34: ...This information is subject to change without notice Keysight Technologies2017 Edition 10 0 October2017 www keysight com...

Отзывы: