background image

Notices

Copyright Notice

© Keysight Technologies 2019–2019

No part of this document may be
reproduced in any form or by any means
(including electronic storage and retrieval
or translation into a foreign language)
without prior agreement and written
consent from Keysight Technologies, Inc.
as governed by United States and
international copyright laws.

Warranty

The material contained in this document
is provided “as is,” and is subject to being
changed, without notice, in future
editions. Further, to the maximum extent
permitted by applicable law, Keysight
disclaims all warranties, either express or
implied, with regard to this manual and
any information contained herein,
including but not limited to the implied
warranties of merchantability and fitness
for a particular purpose. Keysight shall not
be liable for errors or for incidental or
consequential damages in connection
with the furnishing, use, or performance
of this document or of any information
contained herein. Should Keysight and the
user have a separate written agreement
with warranty terms covering the
material in this document that conflict
with these terms, the warranty terms in
the separate agreement shall control.

Technology Licenses

The hardware and/or software described
in this document are furnished under a
license and may be used or copied only in
accordance with the terms of such
license.

U.S. Government Rights

The Software is "commercial computer
software," as defined by Federal
Acquisition Regulation ("FAR") 2.101.
Pursuant to FAR 12.212 and 27.405-3 and
Department of Defense FAR Supplement
("DFARS") 227.7202, the U.S. government

acquires commercial computer software
under the same terms by which the
software is customarily provided to the
public. Accordingly, Keysight provides the
Software to U.S. government customers
under its standard commercial license,
which is embodied in its End User License
Agreement (EULA), a copy of which can
be found at

http://www.keysight.com/find/sweula

or

https://support.ixiacom.com/support-
services/warranty-license-agreements

.

The license set forth in the EULA
represents the exclusive authority by
which the U.S. government may use,
modify, distribute, or disclose the
Software. The EULA and the license set
forth therein, does not require or permit,
among other things, that Keysight: (1)
Furnish technical information related to
commercial computer software or
commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish
to, or otherwise provide, the government
rights in excess of these rights
customarily provided to the public to use,
modify, reproduce, release, perform,
display, or disclose commercial computer
software or commercial computer
software documentation. No additional
government requirements beyond those
set forth in the EULA shall apply, except to
the extent that those terms, rights, or
licenses are explicitly required from all
providers of commercial computer
software pursuant to the FAR and the
DFARS and are set forth specifically in
writing elsewhere in the EULA. Keysight
shall be under no obligation to update,
revise or otherwise modify the Software.
With respect to any technical data as
defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS 227.7102,
the U.S. government acquires no greater
than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as
applicable in any technical data. 52.227-
14 (June 1987) or DFAR 252.227-7015 (b)
(2) (November 1995), as applicable in any
technical data.

Bluetooth

®

and the

Bluetooth

®

logos are

registered trademarks owned by
Bluetooth SIG, Inc., and any use of such
marks by Keysight Technologies is under
license.

– 2 –

Содержание Ixia XGS

Страница 1: ...XGS Chassis Windows 10 Upgrade Guide Release 9 00...

Страница 2: ...e public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be fo...

Страница 3: ...This page intentionally left blank 3...

Страница 4: ...voltages and energy hazards which can cause bodily harm The hot surface symbol indicates that a surface or component is hot The electrostatic discharge ESD symbol indicates proper antistatic precautio...

Страница 5: ...affected The following is an outline of the steps required to accomplish this upgrade task l Create an Acronis Recovery Image l Replace the XGS Chassis Windows 7 partition with an XGS Chassis Windows...

Страница 6: ...Windows 10 license sticker l Check that the chassis to be upgraded is an XGS 940 0010 940 0011 or 940 0110 l Ensure there is physical access to the chassis to be upgraded l Obtain the license activat...

Страница 7: ...Back up Options How to back up Select Backup type Full 6 Back up Options Backup Options Select Change Select Compression Level Select Maximum Select OK 7 Back up Options Select OK to begin Acronis Im...

Страница 8: ...up Utility navigate to the Save Exit tab 6 Under the Boot Override section select the USB device SanDisk in this example 7 The screen should go black and display Press any key to boot from USB Press E...

Страница 9: ...8 On the Windows Boot Manager screen press ENTER to select Windows Setup Procedures 9...

Страница 10: ...following command prompt will automatically appear Wait for the operation to finish 11 A new command prompt appears with the line Ixia Windows 10 Chassis Upgrade asking to confirm that the Windows par...

Страница 11: ...n this as administrator 6 In some cases a warning or a message appears prompting you to accept the changes Select Yes to All 7 When prompted enter the 6 digit serial number of the Standard Performance...

Страница 12: ...installation The setup wizard guides you through the next steps For downloading the installer files go to https support ixiacom com ixos software downloads documentation For details on Windows 10 inst...

Страница 13: ...hassis include Acronis Backup and Recovery imaging software Acronis software allows for restoration of disk images without a network connection or boot media Restoration of the recovery image will ret...

Страница 14: ...Once loaded the Acronis Backup and Recovery ABR console appears as follows Acronis Backup and Recovery Procedure Windows 7 14...

Страница 15: ...select Recover 2 In the Recover Console under the What to recover section select Change 3 In the Backup Archive Selection window navigate to Local Folders Data Recovery Select RecoveryImage and then...

Страница 16: ...ver section Select Change next to Recover Disk 1 MBR to 5 Select Disk 1 as the MBR Destination and then select OK 6 Return to the Where to recover section and then select Change next to Recover Window...

Страница 17: ...sole and select OK The image recovery begins 9 After the recovery is complete close the status Window and from the ABR Console select Actions Exit 10 In the Command Prompt window type exit and press E...

Страница 18: ...evision Policy 817 1019 01 Windows 10 Reimage from Windows 7 Acronis Revert This document shall be controlled approved distributed and revised electronically through Document Control Revision Policy 1...

Страница 19: ...s 7 Acronis Revert THIS DOCUMENT AND THE DATA DISCLOSED HEREIN OR HEREWITH IS PROPRIETARY AND IS NOT TO BE REPRODUCED USED OR DISCLOSED IN WHOLE OR IN PART TO ANYONE WITHOUT THE WRITTEN PERMISSION OF...

Страница 20: ...Ixia a Keysight Business 26601 West Agoura Road Calabasas California 91302 Keysight Technologies 2019 2019...

Отзывы: