Keysight E8363B/C and E8364B/C Installation Note 17
General Information
Installation Procedure for the Upgrade Kit
Step 6.Install the Option UNL Cables
Analyzers WITHOUT Option 014
Refer to
for the following procedure. The new parts are
listed in
1.
Install the following cables in the order listed:
—
Ribbon cable
①
8121-0819A36 step attenuator to A16 motherboard
(P1 SRC ATT)
—
Ribbon cable
8121-0119A37 step attenuator to A16 motherboard
(P2 SRC ATT)
—
W52E8364-20056A22 switch splitter to A37 step attenuator
—
W51E8364-20055A22 switch splitter to A36 step attenuator
—
W8E8364-20175Channel R2 detector to A29 channel R2 mixer
—
W7E8364-20174Channel R1 detector to A28 channel R1 mixer
—
W56E8364-20168A39 bias tee to A26 test port 2 coupler
—
W55E8364-20167A38 bias tee to A25 test port 1 coupler
—
W54E8364-20077A37 step attenuator to A39 bias tee
—
W53E8364-20077A36 step attenuator to A38 bias tee
2.
Route the bias tee control cables through the cable clamp, (item
③
), to
the rear of the analyzer for connection to the A16 motherboard later.
3.
Reinstall the semirigid cables, (item
④
), to the detectors.