Caution
General Safety Precautions

-

General Safety Precautions

The following general safety precautions must be observed during all phases of 

operation, service, and repair of this instrument. Failure to comply with these 

precautions or with specific WARNINGS elsewhere in this manual may impair 

the protection provided by the equipment. Such noncompliance would also 

violate safety standards of design, manufacture, and intended use of the 

instrument. Keysight Technologies assumes no liability for the customer’s 
failure to comply with these precautions.

• Ground the Instrument

To avoid electric shock, the instrument chassis and cabinet must be 

grounded with the supplied power cable’s grounding prong.

• Do NOT Operate in an Explosive Atmosphere

Do not operate the instrument in the presence of inflammable gases or 

fumes. Operation of any electrical instrument in such an environment 

clearly constitutes a safety hazard.

• Keep Away from Live Circuits

Operators must not remove instrument covers. Component replacement 

and internal adjustments must be made by qualified maintenance 

personnel. Do not replace components with the power cable connected. 

Under certain conditions, dangerous voltage levels may remain even after 

the power cable has been disconnected. To avoid injuries, always 

disconnect the power and discharge circuits before touching them.

• DO NOT Service or Adjust the Instrument Alone

Do not attempt internal service or adjustment unless another person, 

capable of rendering first aid and resuscitation, is present.

• Do NOT Substitute Parts or Modify the Instrument

To avoid the danger of introducing additional hazards, do not install 

substitute parts or perform unauthorized modifications to the instrument. 

Return the instrument to a Keysight Technologies Sales and Service Office 

for service and repair to ensure that safety features are maintained in 

operational condition.

The E5080B complies with INSTALLATION CATEGORY II as well as 

POLLUTION DEGREE 2 in IEC61010-1. The E5080B is an INDOOR USE 

product.

The LEDs in the E5080B are Class 1 in accordance with IEC60825-1, 

CLASS 1 LED PRODUCT.

Содержание E5080B

Страница 1: ...Installation Guide Keysight E5080B ENA Series RF Network Analyzers...

Страница 2: ...ided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which...

Страница 3: ...mperature or electrical shock during operation Power cable plug or receptacle on instrument is damaged Foreign substance or liquid has fallen into the instrument Do not exceed the operating input powe...

Страница 4: ...tives and carries the CE marking accordingly The Low Voltage Directive 2014 35 EU The EMC Directive 2014 30 EU To obtain Declaration of Conformity please contact your local Keysight Technologies sales...

Страница 5: ...inals to mains This equipment is a POLLUTION DEGREE 2 INDOOR USE product This equipment is tested in stand alone condition and in combination with the accessories supplied by Keysight Technologies aga...

Страница 6: ...way from Live Circuits Operators must not remove instrument covers Component replacement and internal adjustments must be made by qualified maintenance personnel Do not replace components with the pow...

Страница 7: ...certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology to the extent allowed by the Institution s calibration facility or by the...

Страница 8: ...urnishing use or performance of this document or any information contained herein Should Keysight and the user have a separate written agreement with warranty terms covering the material in this docum...

Страница 9: ...Help hard key on the front panel to open Quick Start helps in understanding the E5080B operation quickly The latest version of online help is available at http www keysight com manuals e5080b The onli...

Страница 10: ...10 Keysight E5080B ENA Series RF Network Analyzers Caution Manuals for E5080B...

Страница 11: ...Requirements 14 Operating Environments 14 Ventilation Requirements 14 Protection Against Electrostatic Discharge ESD 15 Ensuring Adequate Free Space around Analyzer for Immediate Disconnection of Pow...

Страница 12: ...12 Keysight E5080B Installation Guide Contents Procedure to execute the factory recovery 23...

Страница 13: ...he specified options Step 4 After checking if one of the following applies contact your nearest Keysight Technologies sales and service office 1 The packing box or shock absorbing material used to pac...

Страница 14: ...by providing appropriate cooling clearance around the analyzer or for the rack mount type by forcefully air cooling inside the rack housing For more information on environmental temperature to satisf...

Страница 15: ...age by the electrostatic discharge ESD as shown in Figure 1 1 Figure 1 1 Example of the static safe work station Ensuring Adequate Free Space around Analyzer for Immediate Disconnection of Power Cable...

Страница 16: ...ng you against electrical shock from the power outlet Step 1 Confirm that the power cable is not damaged Step 2 Use the supplied cable to connect between the power cable receptacle Figure 1 2 on page...

Страница 17: ...E5080B uses the following fuse types UL CSA Type Slow Blo 8 A 250 Vac Connecting the BNC Adaptor Option 1E5 When the E5080B is equipped with Option 1E5 high stability frequency standard connect the BN...

Страница 18: ...or send a shutdown command from the external controller to activate the shutdown process the process of software and hardware necessary to turn OFF the power supply This puts the E5080B into the stan...

Страница 19: ...necessary to disconnect the power supply in order to avoid shock hazards etc pull out the power cable plug from either the AC outlet side or the E5080B side To allow this operation to be performed sm...

Страница 20: ...art up the E5080B for the first time you need to perform the initial registration of the Windows operating system of the E5080B When the Windows agreement message box appears click Agree The rest of t...

Страница 21: ...oting during startup Symptom Solution Turning on the standby switch does not start up the system Confirm that the power cable is properly plugged in The system starts up but it automatically shuts dow...

Страница 22: ...tting o The driver for the supported printer installed after purchase is deleted o You need to execute initial registration again Files that you have created using the save function files in the D dri...

Страница 23: ...ct all of the USB device from the USB ports Step 3 Connect the keyboard to the E5080B Step 4 Press the standby switch of the E5080B to turn it ON Step 5 When the screen as shown in the figure below ap...

Страница 24: ...ng System Recovery 2 Step 6 Software End User License Agreement appears Press Agree Figure 2 2 Software End User License Agreement Step 7 Type 2 to select Recover the original factory system image opt...

Страница 25: ...he amount of data Figure 2 5 System configuration progress screen Step 10 Once the recovery process is completed completion message prompts Click OK The E5080B restarts automatically Step 11 Software...

Страница 26: ...26 Keysight E5080B ENA Series RF Network Analyzers Troubleshooting System Recovery 2...

Страница 27: ...peration environment 14 ventilation space 14 error correction temperature range 14 Exclusive Remedies 8 I Inspection checking the shipment 13 P power check the power supply 16 disconnection from suppl...

Страница 28: ...Keysight E5080B Installation Guide Index 28...

Страница 29: ...This information is subject to change without notice Keysight Technologies 2019 Edition 1 March 2019 E5080 90010 E5080 90010 www keysight com...

Отзывы: