1-6
Keysight B1542A User’s Guide, Edition 10
Introduction
Typical Technical Information
Typical Technical Information
The followings are the typical technical information of the pulsed IV test system
configured by Keysight B1542A. Those are not the specifications but the typical and
supplemental data the test system can provide.
Gate pulse width: 10 ns to 1
s
Gate pulse voltage:
-
4.5 V to 4.5 V
Gate pulse base line voltage:
-
3.0 V to 3.0 V
Gate pulse amplitude: maximum 4.5 V
Gate pulse period: 100
s
Drain pulse maximum measurement current: 80 mA
Drain pulse current measurement resolution: 1
A
Drain voltage range:
-
10 V to 10 V