[SOURce:]CURRent:PROTection:STATe ON|1|OFF|0
[SOURce:]CURRent:PROTection:STATe?
Enables or disables current protection.
Parameter
Typical Return
ON|1|OFF|0
0 (OFF) or 1 (ON)
Enable limit control operation: CURR:PROT:STATe OFF
– ON (TRIP): Turns OUTPUT off and activates the alarm for overload conditions longer than three seconds.
– OFF (LIMIT CONTROL): Decreases output voltage to keep current at or below the limit when an overload occurs.
– To clear an overcurrent condition, remove the condition's cause and send
– If overcurrent protection is enabled and the output goes into current limit, the output is disabled and the
Questionable Condition status register OCP bit is set.
– The
command sets this parameter to ON.
DISPlay Subsystem
The DISPlay subsystem controls the front-panel display.
DISPlay[:WINDow]:METer:COUPling AC|DC|ACDC
DISPlay[:WINDow]:METer:COUPling?
Selects the data to show on the meter display.
Parameter
Typical Return
AC|DC|ACDC
AC, DC, or ACDC
Set the meter to display DC measurements: DISP:MET:COUP DC
– AC shows pure AC measurement data, DC shows DC measurement data, and ACDC shows all AC and DC
measurement data.
– The
command sets this parameter to ACDC.
Keysight AC6800 Series Operating and Service Guide