Using the 53210A Web User Interface
1. Preparing for Use
Keysight 53210A
350 MHz RF Counter
Product Reference CD-ROM.
All product documentation, software, and examples
are included on the
Keysight 53210A/53220A/53230A Product Reference CD-ROM
.
*53210-90005*
Quick Start Tutorial
© Keysight Technologies 2011, 2014
Printed In Malaysia August 2014 E0814
53210-90005 Edition 3
Channel 2
Opt. 106/115
N-Type (f)
6. Data Logging
7. Utility Functions
The Web User Interface (UI) is a built-in instrument utility that provides SCPI programming control of
the instrument through its LAN interface. The Web UI uses a Java
™-enabled PC Web browser and
requires no external instrument drivers.
1
2
3
4
Connect a standard LAN cable directly between the counter and the PC, or between the
counter and a network switch. Open the Web browser.
Use the ‘Data Log’ key to log
readings over time or based on
reading count.
Example: - log 1,000 readings
- use default path and file name
- specify location of data log file
(default = Internal\DataLog)
- set logging duration (
‘Readings’)
- number of readings to log
- starts data logging
(
select ‘Yes’ to overwrite existing file)
- displays the trend chart when logging
is complete.
Utility functions are counter operations
and settings common to multiple types
of counter measurements. Below is a
summary of what the utility menus
provide.
Obtain the IP address from the counter’s ‘About’ window using the following keys:
- open the Help topic window
- press the About softkey
Enter the IP address in the browser’s address
window. This opens the Web UI home page.
Open the Interactive IO window by clicking
on the ‘Remote Control’ menu icon.
Enter commands from the counter’s SCPI command set using
the ‘Command’ window. Query commands which include ‘?’
return data and can be sent using
Send & Read
. Commands which
do not return data are sent using
Send Command
.
If prompted,
click on ‘Enter Password’ to view
the password protected page. When shipped
from Keysight, there is no password
protection.
- perform a calibration or auto-calibration,
read temperature within instrument
- battery option 300 enable and
charge level (if installed)
- display control, date/time settings,
folder and data/state file operations,
browser control (internal and external
memory)
- self-test, time base, measurement time
out, auto-level
- enable/edit LAN, USB, and GPIB
interface settings
- store and recall user-defined states, set
specific power-on states, restore factory
default settings
For Further Information
1.
Keysight 53210
A User’s Guide
2.
Keysight 53210A/53220/53230A Service Guide
3.
Keysight 53210
A Programmer’s Reference
4.
Keysight
53210A/53220/53230A Product Reference
CD
www.keysight.com/find/53210A
Connect the Power Cord.
Then plug in the instrument.
The Keysight 53210A counter
automatically senses standard power line
voltages and frequencies. There are no
switches to set or fuses to change.
Check the Web for
the latest firmware
Adjust the Carry Handle
Grasp the handle by the
sides and
pull outward:
Adjust the handle to the
desired position:
Max input +27 dBm
(5 Vrms)
Input Terminals
Channel 1
BNC (f)
7.5 Vpk into 50
W
50V Max (AC/DC)
Damage Level: 350 Vpk
Battery Operation: 42V Max
To remove, see instructions
on underside of handle.
Readings are saved and displayed within a
trend chart as they are logged. (The application
can be stopped before the duration ends.)
!