Using the 53210A Web User Interface 

1. Preparing for Use

Keysight 53210A 

350 MHz RF Counter

Product Reference CD-ROM. 

All product documentation, software, and examples 

are included on the 

Keysight 53210A/53220A/53230A Product Reference CD-ROM

.

*53210-90005*

Quick Start Tutorial

© Keysight Technologies 2011, 2014
Printed In Malaysia      August  2014                E0814

53210-90005                                       Edition 3

 

Channel 2

Opt. 106/115

N-Type (f)

6. Data Logging

7. Utility Functions

The Web User Interface (UI) is a built-in instrument utility that provides SCPI programming control of 
the instrument through its LAN interface. The Web UI uses a Java

™-enabled PC Web browser and 

requires no external instrument drivers.

1

2

3

4

Connect a standard LAN cable directly between the counter and the PC, or between the 
counter and a network switch. Open the Web browser. 

   

Use the ‘Data Log’ key to log  

   readings over time or based on 
   reading count.

   Example: - log 1,000 readings
                   - use default path and file name

- specify location of data log file  
  (default = Internal\DataLog)   

- set logging duration (

‘Readings’)    

- number of readings to log    

- starts data logging 
(

select ‘Yes’ to overwrite existing file)   

- displays the trend chart when logging 
   is complete.    

   Utility functions are counter operations 
   and settings common to multiple types   
   of counter measurements. Below is a 
   summary of what the utility menus 
   provide.

 

Obtain the IP address from the counter’s ‘About’ window using the following keys: 

- open the Help topic window

- press the About softkey

Enter the IP address in the browser’s address 
window. This opens the Web UI home page. 

Open the Interactive IO window by clicking
on the ‘Remote Control’ menu icon. 

Enter commands from the counter’s SCPI command  set using 
the ‘Command’ window. Query commands which include ‘?’ 
return data and can be sent using 

Send & Read

. Commands which 

do not return data are sent using 

Send Command

.  

If prompted, 

click on ‘Enter Password’ to view 

the password protected page. When shipped 
from Keysight, there is no password 
protection.   

- perform a calibration or auto-calibration,  
  read temperature within instrument     

- battery option 300 enable and  
  charge level (if installed)    

- display control, date/time settings, 
  folder and data/state file operations, 
  browser control (internal and external 
  memory)    

- self-test, time base, measurement time 
  out, auto-level     

- enable/edit LAN, USB, and GPIB 
  interface settings    

- store and recall user-defined states, set  
  specific power-on states, restore factory 
  default settings    

For Further Information

1. 

Keysight 53210

A User’s Guide

2. 

Keysight 53210A/53220/53230A Service Guide

3. 

Keysight 53210

A Programmer’s Reference

 

4. 

Keysight

 

53210A/53220/53230A Product Reference 

CD

www.keysight.com/find/53210A  

   

Connect the Power Cord.

Then plug in the instrument.

    
 The Keysight 53210A counter 
automatically senses standard power line 
voltages and frequencies. There are no 
switches to set or fuses to change.

Check the Web for 
the latest firmware

Adjust the Carry Handle 

Grasp the handle by the
sides and 

pull outward:

Adjust the handle to the
desired position:

Max input +27 dBm

(5 Vrms)

Input Terminals

Channel 1

BNC (f)

7.5 Vpk into 50

W

50V Max (AC/DC) 
Damage Level: 350 Vpk

Battery Operation: 42V Max

To remove, see instructions 
on underside of handle.

   Readings are saved and displayed within a 
   trend chart as they are logged. (The application 
   can be stopped before the duration ends.)

!