background image

 20                                                                                                           Keysight 16089A/B/C Kelvin Clip Leads

Preparation for Use
OPEN and SHORT Compensation

3-

Содержание 16089A

Страница 1: ...Operation and Service Manual Keysight 16089A B C Kelvin Clip Leads...

Страница 2: ...puter software under the same terms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial lic...

Страница 3: ...l Performance Characteristics of 16089B 9 Supplemental Performance Characteristics of 16089C 9 2 Preparation for Use Introduction 11 Initial Inspection 11 16089A 12 16089B 13 16089C 14 Ambient Environ...

Страница 4: ...4 Keysight 16089A B C Operation and Service Manual Contents...

Страница 5: ...both general and specific information To use the 16089A B C to perform a specific function without having to read the entire manual follow the directions in Using the 16089A B C Using the 16089A B C T...

Страница 6: ...direct attachment four terminal pair type test leads that are equipped with two insulated Kelvin clips Three sizes of Kelvin clips are provided The 16089A Kelvin Clip Leads is equipped with two large...

Страница 7: ...warrant more than normal safety precautions for operator safety Nevertheless service should be performed only by qualified personnel Electrostatic discharge ESD can damage the highly sensitive microci...

Страница 8: ...rformance standards and limits against which the 16089A B C is tested When shipped from the factory the 16089A B C meets the following specifications Maximum dc Bias Voltage 42V peak max Frequency Ran...

Страница 9: ...s additional information for the operator Supplemental performance characteristics are not guaranteed Supplemental Performance Characteristics of 16089A Supplemental Performance Characteristics of 160...

Страница 10: ...10 Keysight 16089A B C Kelvin Clip Leads General Information Supplemental Performance Characteristics 1...

Страница 11: ...hes dents or the like They should also be in perfect electrical condition Verify this by carefully performing an incoming inspection to check the test lead set for signs of physical damage and missing...

Страница 12: ...1 Contents of 16089A Description Keysight Part Number Qty RoHS Compliant Replacement Part Qty Kelvin Clip Leads 16089 600011 1 Keysight internal only part number 1 16089 60601 1 Operation and Service...

Страница 13: ...Contents of 16089B Description Keysight Part Number Qty RoHS Compliant Replacement Part Qty Kelvin Clip Leads 16089 600021 1 Keysight internal only part number 1 16089 60602 1 Operation and Service M...

Страница 14: ...Contents of 16089C Description Keysight Part Number Qty RoHS Compliant Replacement Part Qty Kelvin IC Clip Leads 16089 600031 1 Keysight internal only part number 1 16089 60603 1 Operation and Service...

Страница 15: ...95 at 40 C non condensing Connecting the Test Leads for Use Figure 2 4 Connecting the Test Leads Packaging the Test Leads If shipment to a Keysight Technologies service center is required each test le...

Страница 16: ...16 Keysight 16089A B C Kelvin Clip Leads Preparation for Use Packaging the Test Leads 2...

Страница 17: ...escribes using the test leads and compensation techniques for these test leads Test Leads Features 16089A B C Figure 3 1 16089A B C Test Leads Features 1 Kelvin Clips These are connected to the DUT 2...

Страница 18: ...nt s OPEN and SHORT compensation capabilities must be used The procedures are described in the measurement instrument s operation manual Figure 3 2 Making a Short Condition for the 16089B and 16089C W...

Страница 19: ...etting according to the LCR meter Impedance Analyzer operation manuals 2 Connect the test leads of 16089A B C to the measurement instrument s UNKNOWN terminals 3 Perform OPEN and SHORT compensation as...

Страница 20: ...20 Keysight 16089A B C Kelvin Clip Leads Preparation for Use OPEN and SHORT Compensation 3...

Страница 21: ...n for the 16089A 16089B and 16089C Serial Number for Non RoHS Kelvin Clip Leads 16089A MY44100001 MY44199999 16089B MY40100001 MY40199999 16089C MY44100001 MY44199999 or SG44100001 SG44199999 Serial N...

Страница 22: ...t number is replaced by the respective RoHS Compliant Replacement Part Once the original support part is depleted please proceed to obtain the RoHS compliant support part 16089A Replaceable Parts Red...

Страница 23: ...2 16089B Replaceable Parts Keysight Non RoHS Part Number Description Qty RoHS Compliant Replacement Part Description Qty 16089 60002 Test Leads1 1 The whole unit Keysight internal only part 1 16089B2...

Страница 24: ...6089 60603 Kelvin IC Clip Leads 1 16089 04003 Cover Top 1 16089 606033 3 Poka Yoke Design Change RoHS cover top 16089 04603 is not backward com patible with non RoHS fixture REplace the whole fixture...

Страница 25: ...Keysight 16089A B C Kelvin Clip Leads 25 Service Replaceable Parts Figure 4 1 Kelvin Clip Connections...

Страница 26: ...26 Keysight 16089A B C Kelvin Clip Leads Service Replaceable Parts 4...

Страница 27: ...This information is subject to change without notice Keysight Technologies 1999 2020 Edition 7 January 2020 16089 90030 16089 90030 www keysight com...