background image

Keyscan Inc. A Member of the Kaba Group 

26 

This page is intentionally blank. 

Содержание CIM-LINK

Страница 1: ...re The NETCOM2Ps included with the CIM LINK modules must be programmed with static IP addresses subnet masks and if applicable gateways and Ethernet connection types which you may have to obtain from...

Страница 2: ...version 1 0 1 0 or higher NETCOM Program Tool Utility version 6 0 13 or later Note For global outputs Keyscan recommends using the global OCB 8 option This requires the purchase of an optional OCB 8...

Страница 3: ...ordinate communication loops integrated with the master loop The example above shows two subordinate loops which requires two sets of CIM LINK modules CIM LINK modules are extremely flexible in struct...

Страница 4: ...tes with CIM LINK B Building 3 Install 1 CIM LINK on each subordinate communication loop All CIMs set as slaves Building 1 Building 2 Input B Input A Output Alarm CCTV etc Input C Input A Input B Inpu...

Страница 5: ...r Ethernet Input A Input B and Input C programmed to fire the output in Building 2 Maximum of 2 ACU communication loops may be integrated for global communication when single ACU communication loop is...

Страница 6: ...INK J3 OFF Global Slave J4 ON Single ACU Mode ACU Input B Building 2 Communication Loop Subordinate Single ACU panel communication loop requires only a CIM LINK module serial or network connection to...

Страница 7: ...dule as a global slave jumper J3 OFF When the CIM LINK is set as a group master with jumper J3 ON it enables checking CIM unit heartbeats on the communication loop Ensure that only one CIM or CIM LINK...

Страница 8: ...0 J11 Fault Flashing RJ45 Terminal Jack J1 NETCOMP CIM LINK KI 00485E 10 12 Jumper Off Off 0 Jumper On On 1 Jumper Legend CIM LINK Module Jumper Locations CIM LINK Modes Jumper Setting Notes Reset J1...

Страница 9: ...1 0 Filter global I O messages with ACU S N of 0000 as well as global time zone and global anti pass back messages J12 1 Sets the CIM LINK module to programming mode when NETCOMP plugged into SCKT1 N...

Страница 10: ...w the on screen prompts Note As an option the NETCOMP can be programmed off site before installation providing you have a 12 VDC power supply that can be connected to the CIM LINK s TB4 power terminal...

Страница 11: ...conductors Green Red Black to 12VDC power supply TD1 RD1 TD2 RD2 GND RTS1 CTS1 GND RTS2 CTS2 B3 B2 B1 B0 Diag J2 RESET CAN2 EGND CAN1 GND V 12V SCKT1 Tx Data PC106x J1 J7 J8 J6 J5 CAN2 CAN1 Rx Data 1...

Страница 12: ...ET CAN2 EGND CAN1 GND V 12V SCKT1 Tx Data PC106x J1 J7 J8 J6 J5 CAN2 CAN1 Rx Data 1 2 1 2 1 2 1 2 COM COM CAN CAN J3 J4 J9 J12 Power Good Fault COM2 HDR1 J10 J11 RJ45 Terminal Jack J1 U2 NETCOMP Stand...

Страница 13: ...RN WHT GRN WHT TX RX 485 OUT 485 IN USB cable to 12VDC power supply TD1 RD1 TD2 RD2 GND RTS1 CTS1 GND RTS2 CTS2 B3 B2 B1 B0 Diag J2 RESET CAN2 EGND CAN1 GND V 12V SCKT1 Tx Data PC106x J1 J7 J8 J6 J5 C...

Страница 14: ...N1 GND V 12V SCKT1 Tx Data PC106x J1 J7 J8 J6 J5 CAN2 CAN1 Rx Data 1 2 1 2 1 2 1 2 COM COM CAN CAN J3 J4 J9 J12 Power Good Fault COM2 HDR1 J10 J11 RJ45 Terminal Jack J1 NETCOMP Standoffs To program NE...

Страница 15: ...power source or via the ribbon cable to H2 on the control board 6 Momentarily place a jumper on J1 RESET on the CIM LINK 7 At the PC or laptop select start All Programs and select Keyscan NETCOM Prog...

Страница 16: ...ave to alter the Ethernet Connection Type from automatic negotiation The Ethernet Connection Type is the network speed duplex setting Set the NETCOM so it matches the network equipment setting If the...

Страница 17: ...module Steps to Program the NETCOM2P CIM LINK on Subordinate Communication Loop 1 Mount the CIM LINK module with the NETCOM2P in the designated location on the subordinate communication loop Ensure th...

Страница 18: ...ing If the network equipment was on an automatic setting then reconfigure both the network equipment which may include routers or switches and the NETCOM to a matching fixed speed and duplex setting A...

Страница 19: ...IM LINK Global Master Termination Jumpers ON CAN2 J7 J8 Connect EGND terminal on all CIMs to ground lugs in ACU metal enclosures Global Master Jumper ON J3 CAT 5 CAN Bus H2 KI 00490E 10 12 CAT 5 CAN B...

Страница 20: ...T 5 CAN Bus H2 KI 00491E 10 12 CAT 5 CAN Bus 2 Termination Jumpers ON J5 J6 J7 J8 Slave H1 Slave Jumper OFF J3 H1 NETCOMP RJ45 Terminal Jack to network with path connectivity to PC server with Communi...

Страница 21: ...D V 12V SCKT1 PC106x J1 J7 J8 J6 J5 CAN2 CAN1 1 2 1 2 1 2 1 2 Rx COM COM CAN CAN Tx J3 J4 J9 J12 Power Good Fault COM1 COM2 HDR1 J10 J11 Control Board PC 109x shown with NETCOM2P plugged into M1 socke...

Страница 22: ...2 CAN1 1 2 1 2 1 2 1 2 Rx COM COM CAN CAN Tx J3 J4 J9 J12 Power Good Fault COM1 COM2 HDR1 J10 J11 Control Board PC 109x shown with RS 232 serial connection to PC Common AUX Inputs E 24 23 22 21 20 19...

Страница 23: ...r on J2 to run the CIM in diagnostic mode LED Trouble Indication Code Fault B3 B2 B1 B0 0 0 0 0 0 None 0 0 0 1 1 5V Logic Voltage Low 0 0 1 0 2 12V Input Voltage Low 0 0 1 1 3 5V Isolated Logic Supply...

Страница 24: ...Flashing CIM LINK Boot up When power is applied to the CIM or the reset jumper J1 is momentarily shorted the CIM module will begin its boot up sequence The module uses the 4 diagnostic LEDs to indicat...

Страница 25: ...appropriate settings or jumper pins ON and list network addresses Control Board Model Serial Baud Rate CIM 0 Yes No Serial Network If network Jumper J4 ON OFF IP Address MAC Subnet Gateway CIM Global...

Страница 26: ...Keyscan Inc A Member of the Kaba Group 26 This page is intentionally blank...

Страница 27: ...CIM LINK Setup Guide 27 This page is intentionally blank...

Страница 28: ...uration the CIM LINK NETCOMP is powered from the control board Topology Linear does not support star or ring topologies Inter building Connectivity Yes NETCOM2P Specifications Dimensions 1 9 16 x 1 15...

Отзывы: