10
11
Once all units are discovered and configured, click “Detailed” to be checked off to have basic
control of the matrix system
(Indicator E)
. To switch sources, select a Output first then select
an Input.
Web Interface
The KD-IP1080 Web Interface provides basic configuration settings for operation.
To use the Web Interface, connect a PC to the Smart Managed Switch and ensure that
the IP address is on the same subnet as the KD-IP1080 unit.
First method of connection to a KD-IP1080 unit may be done by using a crossover network
cable directly from your computer. Second method is using a straight cable from KD-IP1080
to the Smart Managed Switch to the computer.
The default TCP-IP address of a KD-
IP1080 Tx unit is 192.168.1.101 and KD-IP1080 Rx is 192.168.1.201.
To enter the Web Interface, ensure that your computer is on the same network as the
KD-IP1080. Connection may also be made directly to the unit with a cross-over cable
for Tx units, or a straight cable for Rx units. Open your web browser and enter the IP
address of the KD-IP1080 into the web cell.
Once connected, the KD-IP1080 web interface would look like this
(Tx on left, Rx on Right)
.
Network Setup, Multicast Setup, and Main Firmware Upgrade are the same for both Tx and
Rx units.