Page 10
7.
“EDID Set Up” options:
»
Input 01-08 plus All Inputs
Use the left selector to choose these.
For each Input selected, ’01-08’ and ‘All’, there are EDID Set Up sub-menu choices:
»
HDMI Output 01 through 08
»
CAT5 Output 01 through 08
»
For each Input (source) selected with the left selector there is a choice to copy the EDID
information from either the HDMI or CAT5 connected Output (display) using the right
selector depending on which is connected. Both HDMI and CAT5 Inputs will receive the
copied EDID information.
»
The Default choices (listed below) copy the EDID from a stored library of EDID configurations
to the selected Input card across both HDMI and CAT5 Inputs.
»
Default EDID 1 – (1080i 2CH PCM)
»
Default EDID 2 – (1080p 2CH PCM)
»
Default EDID 3 – (1080i PCM, DTS/DOLBY. not including HD audio)
»
Default EDID 4 – (1080p PCM, DTS/DOLBY. not including HD audio)
»
Default EDID 5 – (1080i every audio including HD audio)
»
Default EDID 6 – (1080p every audio including HD audio)
»
Default EDID 7 – (3D 1080p 2CH PCM)
»
Default EDID 8 – (3D 1080p every audio including HD audio)
Use the right selector to choose these and push to confirm choice. You will receive a “Completed”
message when successful, or a “Failed” message if unsuccessful.
8.
“TCP / IP” options:
»
IP address
»
Sub net Mask
»
Port
½
The default IP address is; ‘192.168.000.233’ This can be changed to accommodate your
particular configuration or controller.
½
The default Sub net mask is ‘255.255.255.000’ and may also be changed to accommodate your
particular configuration.
½
The default Port number is ‘23’
Select the TCP/IP option by pressing the right selector. Highlight the group of numbers you wish to
change by turning the left selector. Change the group of numbers using the right selector. Continue
this procedure until all numbers are chosen. Press the right selector to enter the changes. You may
then press the left selector to return to the previous menu if desired.
9.
“Factory Default” options:
This option will return the unit to its Factory Default settings. Please see the list of default settings
below. When this menu option is chosen, you will be presented with a choice of EDID’s from the
default EDID library. Choose one of these default EDID’s (typically default 1-1080i 2Ch PCM) using
the left selector, then press the right selector to confirm. The unit will then reset to the default
configuration including the EDID you have chosen.