background image

29

28

Specifications

Technical:

 

»

Power Supply: KD-PS12V1ASC, 12V/1A, 100-240VAC, 50-60Hz, 
Interchangeable head, screw-in connector

General:  

 

»

Regulation:

 CE, RoHS, WEEE

 

»

Enclosure: 

Black Metal

 

»

Product Dimensions:

  5.06” x 3.08” x 0.78”

 

»

Packaging Dimensions:

  5.78” x 4.01” x 3.46”

 

»

Product Weight:

  0.5 lb

 

»

Shipping Weight:

  1.5  lb

 

All 3 ports share the same resources for IR burst generation. If more than one port is 
configured for IR Emitter Mode, the data received will be queued by KD-CX800. The 
device will then check the data buffer and generate the burst one by one. The receive 
buffer size of each I/O port is 1024 bytes. If the receive buffer is full, all incoming 
data will be discarded until all data found in the receive buffer is processed by the 
device.

 

If KD-CX800 I/O port is configured for Serial RS-232 mode, all data received from 
linked TCP traffic port will be forwarded back through this TCP port. If the traffic 
connection is closed, the timeout timer will start and the device will keep receiving 
data. If the traffic connection is opened again before the timer has expired, the data 
will be sent back. If there is no connection before the timer has expired, the device 
will close the port and clear any received data found in the buffer.

 

The RS-232 data buffers for I/O ports 2 and 3 can hold a maximum of 2048 bytes.

 

For I/O ports configured as trigger mode, output and input is enabled. The trigger 
output can be set by both the TCP control port and the TCP traffic port. For trigger 
input, a timer can be set to get the input state periodically. The trigger input state 
is also automatically updated through the TCP traffic port when the input state has 
changed. It is possible to query the input state directly on the TCP traffic port by 
sending the string: 

 

»

TRIN\r

Содержание KD-CX800

Страница 1: ...l led by digital video pioneer Mike Tsinberg develops and manufactures high quality cutting edge technology solutions for virtually all applications where high end video and control are important Key...

Страница 2: ...ports used Mode 3 Third Party Control via KeyCode Open API Cost effective control expansion with advanced third party control systems Adds reliable hardware interface to network based control apps En...

Страница 3: ...evel Low 0V ground fixed High 3 3V 11 4V Does not support relay or contact closure functionality Does not support extension of digital data Connections LEDs The three multi function I O ports can be c...

Страница 4: ...ght Info PC HDMI KD IP120Tx Computer HDMI KD IP120Tx KD IP120Rx HDMI KD IP120Rx HDMI KD IP120Rx HDMI KD IP120Rx HDMI KD IP120Rx HDMI KD IP120Rx HDMI Voltage Sensor Compatible ports 1 2 and 3 Supported...

Страница 5: ...00 must be on the network connected to either LAN port 1 or LAN port 2 If controlling via RS 232 connect from third party control processor or computer into I O port 2 If controlling via IR connect to...

Страница 6: ...800 can be used as a Master Controller for Key Digital s Compass Control system KD CX800 lives on the network and communicates with iOS or Android controllers to execute IR RS 232 TCP IP or Voltage co...

Страница 7: ...configuration for each I O port using the web control interface See Web Control Interface section for more information The desired configuration can only be applied to an I O port using the web contro...

Страница 8: ...a unique multicast group ID number assignment Example Installation Install up to eight units in an equipment rack using KD RK120PLT KD RK120PLT also houses Enterprise AV Tx or Rx units Mode 4 Control...

Страница 9: ...it in a web browser to access a web control interface for unit and I O port setup Web control interface home page Displays unit information Network setup options including enable disable DHCP Control...

Страница 10: ...17 16 Image 3 Setting control mode for KeyCode Open API usage KeyCode Open API Image 2 Setting control mode for Compass Control master control usage...

Страница 11: ...ation port assignment is flexible and can be adjusted using the SetTCPC TCP port r Separate TCP ports are used for I O port traffic data IP Port number assignments for I O ports are flexible and assig...

Страница 12: ...it 1 1 bit 2 1 5 bit 3 2 bit parity Parity of RS 0 no parity 1 odd 2 even 3 mark 4 space 5 multidrop timeout Time in milliseconds that the I O port will be open More info in the notes section Set I O...

Страница 13: ...number time interval Frequency in milliseconds that the I O port will return current voltage state More info in the notes section Set I O Port to Trigger Mode Ex SetTR 3 1000 r SetTCPC tcp port TCP p...

Страница 14: ...mode IROUT I O port is IR Output mode RS I O port RS 232 mode TR IO port is Trigger Input output mode stop bit RS 232 stop bit setting 1 1 stop bit 1 5 1 5 stop bits 2 2 stop bits parity RS 232 parity...

Страница 15: ...582 the device will send that IR burst to I O port 2 with 2 repeats The repeated pulses are 538 40348 and 9019 2312 They will be inserted after the 9019 2312 pulse Notes Only I O port 1 is capable of...

Страница 16: ...erial RS 232 mode all data received from linked TCP traffic port will be forwarded back through this TCP port If the traffic connection is closed the timeout timer will start and the device will keep...

Страница 17: ...afety Instructions Please be sure to follow these instructions for safe operation of your unit 1 Read and follow all instructions 2 Heed all warnings 3 Do not use this device near water 4 Clean only w...

Страница 18: ...com Customer Support For customer support questions please contact us at Phone 914 667 9700 E mail customersupport keydigital com Technical Support For technical questions about using Key Digital pro...