NB. Upon termination of displaying of parameters, you will access the total manoeuvres counter, which are shown in
two different screens where the thousands are indicated by the point lighting up. If you want to rest this counter, press
and hold button P1 and P2 until 0000 is shown
N.B. If the point of the LCD on the left lights up, it means that 10,000 manoeuvres have been exceeded, which must be
added to the value shown.
To exit parameter display, press ENTER several times until automatic closure condition is shown ( -- two dashes).
PROGRAMMING FUNCTIONS
Access the parameter menu by holding the ENTER button until the first parameter, A, appears.
Press the ENTER button repeatedly to advance through the parameters menu. To change the pa
-
rameter press ↕ UP/DOWN
N.B.: any variation in function must be made with the automation closed
FUNCTIONS \ VALUES
WORKING TIME M1
(seconds)
5
6
9
12
15
18
21
24
27
30
+3sec
WORKING TIME M2
(seconds)
5
6
9
12
15
18
21
24
27
30
+3sec
M1 DELAY TIME
(seconds)
--
0
1
4
10
With this selection you can delay start-up of the
second motor M1 by the set time
AUTOMATIC CLOSURE
(seconds)
NO
5
10
15
20
25
30
40
80
120
OPEN COMMAND
Open
Stop
close
Open
Close
By activating the step/step function, you avoid passage of the automation in the
stop state. The enabled function may be critical for automations with high inertia.
% DECELERATION
NO
10%
20%
30%
When the deceleration function is activated in the last seconds
of operation of the automation, the control unit slows the mo-
tors based on the selected %.
ELECTRIC LOCK HAM-
MERING
NO
YES
If you select the Hammering parameter, the control unit facilitates the release of
the electric lock, ordering the motors to close for a short time
FLASHER OUTPUT
Flashing Courtesy
light
With this selection you can select output N°9-10 as flasher or courtesy light
CONDOMINIUM
(OPENING ONLY)
NO
YES
Activate the condominium function so that the first step/step impulse opens and
accepts only re-opening during closing
MOTOR WARM-UP
(minutes)
NO
15
25
40
If you insert parameter I = from 1 to 3 and if the gate is standing
closed in standby at the end of the set time there will be a closure
of both doors of 1 min. at a value of power that does not damage
the motor or the mechanics. This makes it possible to keep the
internal temperature of the electric motor at a point where ice does
not form in the mechanical reduction gear. This function should be
used when temperatures of less than 5°C are expected.
MOTOR FORCE
100%
Max
10% Min
20%
30%
40%
50%
60%
70%
80%
90%
N° OF MOTORS
2
1
Parameter of selection of automation with 1 or 2 motors
CLOSE AFTER TRANSIT
NO
YES
When you activate the Close After Transit function with automatic closure activated, the
automation is closed in the shortest time possible without waiting for automatic re-closing.
TIMER/MAGNETIC COIL
ON STEP/STEP
NO
YES
When you activate the function Timer / Magnetic Coil via parameter P after termi-
nating total opening if step/step contact is kept closed the automatic closing time
is locked so that the gate never closes until the step/step contact is opened again,
if there are several step/step impulses during the standby time for automatic
closing the time will be continuously reset
SOFT START
NO
YES
When you activate the Soft Start function, during the first seconds of movement
of the automation the control unit keeps the motor at reduced speed for a softer
start.
ELECTRO LOCK / SCA
(open gate light)
--
ELS
SCA
The SCA function (open gate light) allows the connection of a 12Vac
signaling light, max 1W, in the electro lock output
DEAD MAN FUNCTION
NO
YES
When you activate the dead man function via parameter U, you can open the auto-
mation until step/step contact is closed and close the automation until contact PED is
closed; when the two contacts are released the automation goes to STOP position.
PRE-FLASHING
NO
1sec
2sec
4sec
When the pre-flashing function is activated, before any move
-
ment in closing the flasher is activated for the selected time
www.ga
ł
ecki.pl
Содержание 900CT-201
Страница 9: ...NOTE ANMERKUNGEN NOTES NOTA NOTES OBSERVAÇÕES w w w g a ł e c k i p l ...
Страница 17: ...NOTE ANMERKUNGEN NOTES NOTA NOTES OBSERVAÇÕES w w w g a ł e c k i p l ...
Страница 25: ...NOTE ANMERKUNGEN NOTES NOTA NOTES OBSERVAÇÕES w w w g a ł e c k i p l ...
Страница 33: ...NOTE ANMERKUNGEN NOTES NOTA NOTES OBSERVAÇÕES w w w g a ł e c k i p l ...
Страница 41: ...NOTE ANMERKUNGEN NOTES NOTA NOTES OBSERVAÇÕES w w w g a ł e c k i p l ...
Страница 49: ...NOTE ANMERKUNGEN NOTES NOTA NOTES OBSERVAÇÕES w w w g a ł e c k i p l ...
Страница 57: ...NOTE ANMERKUNGEN NOTES NOTA NOTES OBSERVAÇÕES w w w g a ł e c k i p l ...