Measurement method

Measurement results

Average display

5. EASY OPERATION GUIDE

Display

Cause

+ +

.

+

The upper limit of the 

displayable

 range is exceeded.

--

.

The lower limit of the 

displayable

 range is exceeded.

**

.

Conversion failed.

(9)  Incere the sample case to the 

measurement chamber.

(14) The measurement is in progress.

(10)  Close the cover with the meas-

urement chamber set. Then, 

press the [NEXT] key.

(11)  The measurement is in progress.

* Never open the cover.

(12)  Take out the sample case, and 

reverse the case, then set it 

again into the chamber.

(13)  Firmly close the cover, and then 

press the [NEXT] key.

* Never open the cover.

(15)  The measurement result will be 

displayed.

*  Pressing the [MEASURE] key in 

this screen will enable a new 

measurement.

*  

Pressing

 the [Home  ] key will 

restore the initial screen.

The average of the measured times 

will be displayed.

When the measurement is repeated, 

the count number increments. (1 to 

9th at maximum.)
Press the [AVG] key.

(16)  The measurement is complete.  

Take out the sample case.

The following is the display example of meas-

urement results within the displayable range.

*  Pressing the [MEASURE] key in this 

screen will enable a new measurement.

*  Pressing the [Home  ] key will restore 

the initial screen.

*  After the average is displayed, the num-

ber of measurement times will be reset 

and the next measurement will be count-

ed as 1st.

Содержание AN-920

Страница 1: ...NIR Rice Composition Analyzer AN 920 Operating Manual Thank you for purchasing this product Please read the operating manual carefully and use this product properly...

Страница 2: ......

Страница 3: ...ts of Main Unit 6 2 3 Accessories 7 3 SPECIFICATIONS 8 4 DESCRIPTION OF OPERATION KEYS 9 5 EASY OPERATION GUIDE 10 6 ADJUSTMENT 12 7 SETUP 13 8 OTHERS 16 8 1 Printer Output 16 8 2 Replacing Fuses 16 8...

Страница 4: ...a place where explosive inflammable gas or liquid substance exists Otherwise it may cause explosion fire or electric shock etc Do not use other than rated power supply voltage If overvoltage is applie...

Страница 5: ...le or other cables never pull on the cord or cable and instead hold the plug or cable connector Do not install the unit in a place where handling the power cable and connectors or turning the power sw...

Страница 6: ...e a tungsten lamp is used High measurement accuracy can be achieved by adopting a method in which the transmitted light from the sample is detected after being diffracted into 600 to 1100 nm by a spec...

Страница 7: ...ccessories Spare fuse Sampling cup Power cable Sample case 2 Operating manual Storage container Standard sample Storage container Standard sample brown rice milled rice 1 each Stored in the storage co...

Страница 8: ...ns and weight 230 W 400 D 250 H mm 8 5 kg Accessories Power cable Fuse Sample case 2 Sampling cup Standard sample brown rice milled rice 1 each storage container standard sample operating manual Optio...

Страница 9: ...he value 7 SETUP P 13 14 15 Display date time communica tion light intensity reset and user switching can be set 6 ADJUSTMENT P 12 Adjustments are required before starting the measurement There are tw...

Страница 10: ...ommended to keep the tempera ture of the sample and the environ mental temperature close Clean the sample case If the window of the sample case is not clean or significantly scratched adjustment or me...

Страница 11: ...ver open the cover 15 The measurement result will be displayed Pressing the MEASURE key in this screen will enable a new measurement Pressing the Home key will restore the initial screen The average o...

Страница 12: ...anually calculated Change the value with keys and then press the Enter key 4 Pressing the Home key will restore the initial screen Procedure 1 Press the Adjustment key 2 The measured value of the stan...

Страница 13: ...he Setup key 2 Press the DISPLAY key 3 For each item press to display and to hide 4 To set the display range press the value Change the value with keys and press the Enter key When Protein CM is set t...

Страница 14: ...When the tungsten lamp is blown replace the lamp in the following procedure Make sure to purchase the new lamp from Kett Do not use other lamp than specified one While the power is turned on the lamp...

Страница 15: ...asurement Calibration curve selection Bias adjustment Display setting Date Time setting Communica tion setting Light intensity resetting User addition Administrator User Guest 3 Switching the user Pro...

Страница 16: ...easurement Sample is too dark bright Instrument temperature is too low high Sample temperature is too low high A D Converter Error Replace lamp The following messages may be displayed during initializ...

Страница 17: ...refrigerator Never store the sample in the freezer The sample will be frozen Other than the appropriate storage it may cause a change to the standard value The validation period indicated on the stand...

Страница 18: ......

Страница 19: ......

Страница 20: ...and parts depicted in this user manual may not appear exactly as their actual counterparts but this does not affect their operation or functionality This user manual was intended to be written as clea...

Отзывы: