1.  Attach a Sample

The coefficient of friction between to samples can be measured either by attaching the samples to the slider 

with two-sided tape or by fixing the samples in place using the O ring supplied attached to the slider. 
●   Affixing samples using two-sided tape

  Use a piece of two-sided tape pre-cut to a size slightly smaller than the samples to affix 

the samples to the slider.

●   Affixing samples using the O-ring

  Remove the O-ring which is attached to the slider and then wrap the O-ring around the 

samples so that they are fixed in place. This method should only be used for thin samples.

*  The displayed coefficient of friction is calculated based upon the weight of the slider (30g). 

It is therefore necessary to take the weight of the attached samples into consideration.

*  When measuring the coefficient of friction between samples, a maximum thickness of 

1mm of sample material may be attached.

2.  Installing the standard slider or 6-point ball slider (option)

1

 Use a slider holder to install the slider as illustrated in the diagram.

2

 Install the standard slider or 6 point ball slider in the same way.

●  Installing the rubber slider (option)

1

 Remove the two bolts which hold the bottom cover in place.

2

 Use screws to fix the spacers in place (2 locations). 

  (Refer to diagram 1.)

3

 Install the rubber slider. (Refer to diagram 2.)

Diagram 1

Diagram 2

6. Using the Portable Friction Meter

Содержание 94i-II

Страница 1: ...Operating Manual Thank you for purchasing this product Please read the operating manual carefully and use this product properly Friction Tester Muse TYPE 94i ll...

Страница 2: ......

Страница 3: ...uction 4 2 Specifications 5 3 External View and Part Names 6 4 Measurement Principle 7 5 The VCM Principle 8 6 Using the Portable Friction Meter 9 7 Notes regarding use 11 8 Technical information 13 9...

Страница 4: ...jects In the past static friction was typically measured using the incline method and a strain gauge However this method posses many difficulties when used in confined spaces such as laboratories etc...

Страница 5: ...rovided in part 7 Characteristics and Performance Display resolution 0 001 Detector VCM Photo sensor Display 7 Segment LED RED 4 digits Materials Main Unit ABS Aluminum Slider Brass hard chrome treate...

Страница 6: ...splay Panel 2 Average Button 3 Power Button 4 Measure Button 5 Main Unit 6 Bottom Plate 7 Slider 8 Battery Case 9 Slider Holder 0 AC Adapter Connector Data Output Connector 0 3 External View and Part...

Страница 7: ...ed in Diagram 1 below when an object of weight W is placed upon a surface which is gradually inclined at an increasing angle at some angle of inclination the acceleration of gravity acting upon the ob...

Страница 8: ...force move at right angles to each other This results in a force being applied to the coil assembly This force is proportional to the value of the current passing through the coil Because this is effi...

Страница 9: ...samples The displayed coefficient of friction is calculated based upon the weight of the slider 30g It is therefore necessary to take the weight of the attached samples into consideration When measur...

Страница 10: ...e holder back into the unit replace the cover and then replace the screws which hold it in place 4 Measurement Method Place the object to be measured upon a horizontal surface and set the unit down ge...

Страница 11: ...t used for a long period of time store it in the case because it should be protected from dust 2 Precautions in measuring Conduct measurement at a horizontal and vibration free place Measurement canno...

Страница 12: ...he surface If the sample surface is still dirty even after the operation above stained with grease for example use an organic solvent such as thinner and benzine to wipe the surface Be careful about t...

Страница 13: ...generated by VCM calculated using a strain gauge Actual measurement example 1 Characteristics and Performance VCM driving force constant calculated using a strain gauge Actual measurement example Cal...

Страница 14: ...be reversed The rough texture felt by your finger is caused by that your finger is caught by unevenness on the surface However when measurement is conducted with the standard slider the slider slides...

Страница 15: ...to be replaced Err2 Communication function Check the cable Err3 Zero return incapability error A malfunction occurred Contact our sales division Lo Insufficient power supply voltage Battery needs to...

Страница 16: ...MEMO...

Страница 17: ...MEMO...

Страница 18: ...MEMO...

Страница 19: ......

Страница 20: ...displayed on this manual may differ from the actual ones however operations and functions are not affected All efforts have been made to ensure the contents of this manual are accurate However if you...

Отзывы: