Installation
STEP 1
Determine Product Location
1. Identify the location of each LS0 luminaire. Each segment box in a run will be labeled and numbered in the
order of the run layout. i.e., Segment #1 of 3, Segment #2 of 3, Segment #3 of 3 in a run with 3 segments.
2. Each LS0 segment must be setback from any walls by at least the minimum setback distance (2 in [50.8 mm]
for high output and long run, 0.25 in [6.35 mm] for uniform lens). Each segment must also have the appropriate
mixing depth for its lens type (4 in [101.6 mm] for high output and long run, 0.25 in [6.35 mm] for uniform lens)
as shown in the figure below.
3. Locate wiring holes for LS0 luminaire.
4. Determine location for X96 controller. Measure the length from the controller to the first luminaire and cut your
4-conductor cable to length. Since this a low-voltage wire, conduits are not required. The total cable length
from the X96 controller to the last LS0 segment may not exceed 50 ft (15.2 m), not including the length of the
luminaires. For example, 30 ft (9.1 m) of cable can be run from the X96 controller to the first 8 ft (2.4 m) segment.
Then 15 ft (4.6 m) of cable can be run to the next 7 ft (2.1 m) segment. Total cable length, NOT including the
luminaire, would be 45 ft (13.7 m) which is under the acceptable length of 50 ft (15.2 m). Total cable length,
including the luminaire, would be 60 ft (18.2 m).
5. Ensure that there are enough adapters to complete your wiring. The X96 controller comes with one adapter
(Adapter Type A on page 4) to connect to the first LS0 segment. Extra adapters must be purchased separately
or as an Adapter Type A-Adapter Type B pair (UN-LS0-ADPT-1).
Note:
Adapter pairs are required when 4-conductor cable is used between any individual segments.
Lens will be evenly
illuminated when
viewed directly
Lens will have visible
hot spots when
viewed directly.
Uniform Lens
(Coming in Phase 2)
High Output &
Long Run
0.25 in (6.35 mm)
Mixing Depth &
Setback Distance
2 in (50.8 mm) Setback
Distance (symmetric)
4 in (101.6 mm)
Mixing Depth
8 |
LS0
INSTALLATION GUIDE
P/N 3662707 Rev A
© 2022 Lutron Electronics Co., Inc. All rights reserved.
Содержание LS0
Страница 1: ...LS0 LOW VOLTAGE LINEAR Installation Guide Models CM LS0 Coming in Phase 2 HW LS0...
Страница 14: ...LS0 LIN AIRE BASSE TENSION Guide d installation Mod les CM LS0 venir dans la phase 2 HW LS0...
Страница 27: ...LS0 LINEAL DE BAJO VOLTAJE Gu a de instalaci n Modelos CM LS0 que viene en Fase 2 HW LS0...
Страница 44: ...6231 E Stassney Ln Bldg 13 Suite 400 Austin TX 78744 www ketra com 512 872 4349 P N 3662707 Rev A...