background image

TROUBLESHOOTING GUIDE

Problem

Light doesn’t turn ON

Unit is flickering

Solution

Make sure the unit is connected to the power supply and the power 
supply is connected to an outlet with the correct specifications.

Make sure you are using a power supply with the correct specifications.

Make sure the unit has not overheated by operating at a room 
temperature exceeding 40°C.

Make sure electrical power is available to the AC outlet being used.

Make sure the power supply has the right specifications.

Make sure the device is operating within the specified operating 
temperature range. If unit overheats, it will automatically shut down.

Make sure the fan is operating properly.

Controllability

Multiple A160WE lights can be controlled by either a single 

external 0~10V controller or manually.

MAINTENANCE

1.  Keep the air venting holes (E), and fan clear of dust. To clean the fan, unplug the unit 

and insert the tip of a CO2 dust blower (or similar dust blower) in one of the venting 
holes (E) on the unit's outer shell. Hold and spray. You can also gently vacuum the 
light through the venting holes.

2.  Keep the lens (G) clean. If the lens becomes contaminated with water, dust, or other 

particles, unplug the unit and clean the lens with isopropyl alcohol. Wet a cotton swab 
or a napkin in isopropyl alcohol, gently wipe the surface of the lens, and let it dry.

    CABLES

    Available cables:  

  • Control Cable (Please consult kessil.com 

for list of available cables and compatible 
controllers).

 

 

•  Unit Link Cable (6' male/male with 3.5 mm 

stereo jack).

 • Control Extension Cable (6' male/female 

with 3.5 mm stereo jack).

    

STARTING A CHAIN

    Connect two or more lights with the Kessil 

Link Cable, as shown to the above.

    CONTROL METHODS

    There are two ways to control a chain of lights:
  • With an external controller;
  • Without external controller (Tuning Controls  

on first light control all other lights in chain).

    Should a longer cable be needed, the Kessil 

Extension Link Cable may be used.

    Each light has its own independent power 

supply. Any number of lights can be daisy 
chained together without degradation of 
signal. However, in longer chains a slight 
delay in response may occur. Manual tuning   
is disabled when device senses input cable.

Output

Input

To next light

Input from Controller

Light Intensity Control

Unit Link Cable

Spectral Tuning Control

       This is a LED light source emitting 40 % or more of total 

radiation power of the range 250-800 nm in the range of 
400-480 nm, and intended for coral growth.

@kessilled

@kessil

kessil.com

kessil.led

kessiltube

Отзывы: