4.4
Connection diagram
Connect sensors
Remove dummy cover.
Push in the cable gland M16x1.5 and fix with lock nut.
Push the nut of the cable gland onto the end of the cable.
Feed the wires and cable end through the opening of the
cable gland.
Insert the wires while pushing in the slotted screwdriver at
the same time.
Tighten the nut of the cable gland finger-tight.
Fig. 1: Schematic diagram
4.5
Further connection possibilities
TeleControl GSM modem
Mount the TeleControl modem (art. no. 28792) as described in the corresponding installation instructions 434-033.
Potential-free contact
Connect the potential-free contact as shown on the connection diagram.
Ext. audible alarm
The external audible alarm (art. no. 20162) for transmitting the acoustic warning to other rooms can be connected if neces-
sary (
see "Connection diagram", page 23
EN
016-283
Installation and operating instructions
23 / 96