Einbau- und Betriebsanleitung

31  

010-700_01

3.1.16

Einschaltverzögerung Klappe

s

0 - 99

3.1.17

Nachlaufzeit Klappe

s

0 - 99

3.1.18

Max. Strom Klappe

mA

150 - 200

3.1.19

S1/S3 Pumpenbetrieb

S1 Betrieb/S3 Betrieb

3.1.30

Zugriff Remote Control

3.2

Profilspeicher

3.2.1

Parameter speichern

3.2.2

Parameter laden

3.3

Datum/Uhrzeit

mm:hh - dd.mm.yy

3.4

Anlagenkonfiguration

3.5

Produkttyp

3.5.1

Pumpfix / Ecolift XL Mono

3.5.2

Pumpfix / Ecolift XL Duo

3.5.3

Hebeanlage Aqualift Mono

3.5.4

Hebeanlage Aqualift Duo

3.5.5

Pumpstation Aqualift Mono

3.5.6

Pumpstation Aqualift Duo

3.5.7

Hebeanlage XXL Mono

3.5.8

Hebeanlage XXL Duo

3.6

Anlagenvariante

3.6.1

1 Motorklappe

3.6.2

2 Motorklappen

3.6.5

F Compact

3.6.6

F

3.6.7

F XL 200 l

3.6.8

F XL 300 l

3.6.9

F XL 450 l

3.6.10

S Unterflur

Содержание Comfort PLUS

Страница 1: ...Control Unit Comfort PLUS D Originalbetriebsanleitung 2 GB Original operation manual 37 CN 安装及使用说明书 72 02 2018 010 700 01 ...

Страница 2: ...01 Lenting Deutschland Bei technischen Fragestellungen helfen Ihnen gerne unsere qualifizierten Servicepartner vor Ort weiter Ihren Ansprechpartner finden Sie unter www kessel de kundendienst Bei Bedarf unterstützt unser Werkskundendienst mit Dienst leistungen wie Inbetriebnahme Wartung oder Generalinspektion in der gesamten DACH Region andere Länder auf Anfrage Informationen zur Abwicklung und Be...

Страница 3: ...rs wichtige oder sicherheitsrelevante Information Kursivschreibung Variante oder Zusatzinformation z B gilt nur für ATEX Variante L L Technische Hinweise die besonders beachtet werden müssen 2 Sicherheit Folgende Symbole werden verwendet Zeichen Bedeutung Gerät freischalten Gebrauchsanweisung beachten CE Kennzeichnung Warnung Elektrizität WEEE Symbol Produkt unterliegt RoHS Richtlinie vor Benutzun...

Страница 4: ...ühren gegen die Benutzung durch Unbefugte zu sichern Person1 freigegebene Tätigkeiten an KESSEL Anlagen Betreiber Sichtprüfung Inspektion Batterietausch Sachkundiger kennt versteht Betriebsanweisung Entleerung Reinigung innen Funktionskontrolle Konfiguration des Schaltgerätes Fachkundiger Fachhandwerker nach Einbauanweisung und Ausführungsnormen Einbau Tausch Wartung von Komponenten Inbetriebnahme...

Страница 5: ...elektrostatischen Komponenten Vor dem Berühren der Komponenten auf der Platine Hutschiene berühren Diese Maßnahme stellt sicher dass evtl vorhandene elektrostatische Ladungen ausgeglichen werden indem Sie Ihren Körper erden 2 3 ATEX Explosionsschutz beachten Das EX Zeichen kennzeichnet Komponenten und Produkte welche der ATEX Anforderung ATEX Richtlinie 2014 34 EU genügen Für explosionsgefährdete ...

Страница 6: ...bst ist NICHT für den Einbau in einer EX Zone vorgesehen Alle nicht durch eine ausdrückliche und schriftliche Freigabe des Herstellers erfolgten Um oder Anbauten Verwendungen von nicht originalen Ersatzteilen und Reparaturen durch nicht durch den Hersteller autorisierten Betriebe oder Personen führen zum Verlust der Gewährleistung 2 5 Produktbeschreibung Das Schaltgerät wird zur automatischen Steu...

Страница 7: ...0 5 A Leistungsschütze Schaltkontakte U 400V 10 4kW P2 50Hz Bedienungselem Stromkreis passiv Schalter und Taster Das Schaltgerät ist außerhalb des explosionsgefährdeten Bereichs zu betreiben Die dafür notwendige Klassifizierung Gruppe II Kategorie 1 G zugehöriges Betriebs mittel für Gasatmosphäre Technische Spezifikation Einzelbarriere Niveaustromkreis in Zündschutzart Eigensicherheit Ex ia IIC Kl...

Страница 8: ... 230 V 50 Hz 400 V AC 50Hz Leistung Standby 5W Potentialfreier Kontakt max 42 V DC 0 5 A Batterie 2 x 9V 6LR614 Einsatztemperatur 0 40 C Schutzart IP 54 Schutzklasse I Anschlusstyp Schuko Schaltgerät Direktanschluss Erforderliche Sicherung Mono A C 16 C 16 C 16 C 20 Erforderliche Sicherung Duo A C 16 C 20 C 32 RCD 30 mA Schutzklasse I Duo Anlagen verfügen über zwei Pumpen mit identischen technisch...

Страница 9: ...halter Abb 1 auf Seite 6 in Position OFF befindet Schrauben für Gehäusedeckel lösen und Gehäusedeckel aufklappen Gehäuse am vorgesehenen Ort montieren dazu alle vier Befestigungsmöglichkei ten in den Ecken verwenden Umgebungsbedingungen beachten Im Lieferumfang ist eine Bohrschablone enthalten Anlage freischalten Sicherstellen dass Leitungen und elektrische Komponenten während den Arbeiten von der...

Страница 10: ...gewährleistet ist Netzleitung 230V Schaltgeräte sind steckerfertig Schaltgerät Redundanzklappe installieren Option Bei Verwendung mit Pumpfix Ecolift XL in der Variante mit zwei motorischen Klappen Redundanzverbindung gemäß derAnleitung des Redundanzschaltge rätes am Klemmenblock LIN BUS anschließen Abb 3 Anschlussübersicht Netzleitung 400V Quelle Anschluss Kabel Leitungsart Kennung Anschluss bez ...

Страница 11: ...en 3 adrige Kabel sind für die 230 V Variante deren Pumpe n kann können mittels Phönix kontaktstecker außen an der Unterseite des Schaltgerätes ange schlossen werden Diese Variante wird deshalb in diesem Abschnitt nicht weiter erläutert Für 9 adrige Kabel ist eine Doppelbelegung der Phasen in der Abwasser pumpe Abb 4 vorgesehen Platinenanschlüsse für die Abwasserpumpe 1 3 1 6 Phasen 4 5 7 8 Temper...

Страница 12: ...Ermittlung des Füllstandes verwendet werden diesen wie folgt anschließen Verschlusskappe abziehen Luftschlauch des Drucksensors auf den Anschluss nippel des Druckleitungsanschlusses 1 schieben und mit der Klemmmutter befestigen Luftschlauch stetig steigend verlegen Bei Längen über 10 m oder Gegengefälle des Luftschlauches Kompressor Set zur Lufteinperlung verwenden siehe KESSEL Zubehör Abb 5 ...

Страница 13: ...ziehen und M16 Kabelverschraubung einstecken und mit Gegenmutter befestigen Anschließend Kabel durchziehen und Abdeckung befestigen Schwimmerschalter Mono nicht ATEX Die Leitungsenden der Schwimmerschalter am abgebildeten Klemmen anschließen ALARM ON OFF Probe2 On1 On2 Off Alarm Alarm On Off A Pumpe ausgeschaltet Off B Pumpe einschalten On D Alarm Abb 6 ...

Страница 14: ...hwimmerschalter Duo nicht ATEX Die Leitungsenden der Schwimmerschalter gemäß Abb 7 anschließen Alarm On1 Off On2 Probe2 On1 On2 Off Alarm Alarm On1 Off On2 A Pumpe ausgeschaltet Off B Pumpe 1 einschalten On1 Abb 7 C Pumpe 2 einschalten On2 D Alarm ...

Страница 15: ...en Abb 8 anschließen Das Anschließen von Pegelsonden ist für Mono und Duo Anlagen gleich Anschlussübersicht Pegelsonde Aderfarbe Bez auf Platine Klemmenfarbe Schwarz Probe2 blau Rot schwarz Hinweis Beim Verlängern der Anschlussleitung der Pegelsonde KESSEL Klemmdose Art Nr 28799 verwenden Probe2 On1 On2 Off Alarm Mono Duo sw BK rt RD Abb 8 ...

Страница 16: ...barriere Abb 9 anschließen Das Anschließen von Pegelsonden ist für Mono und Duo Anlagen gleich Abb 9 rt RD 4 bl 3 bl HAZ sw BK Anschlussübersicht Pegelsonde Aderfarbe Bez auf Zenerbarriere Rot plus 3 Schwarz minus 4 Hinweis Beim Verlängern der Anschlussleitung der Pegelsonde KESSEL Klemmdose Art Nr 28799 verwenden ...

Страница 17: ... 4 5 USB Anschluss herausführen Option Damit der auf der Platine befindliche USB Anschluss ohne ein Öffnen des Ge häuses zugängig wird kann eine USB Gehäusebuchse mit Kabel und Stecker zum Einbau in das Gehäuse des Schaltgerätes bei KESSEL bestellt werden Art Nr 28785 4 6 KESSEL TeleControl Modem Option Das KESSEL Tele Control Modem Art Nr 28792 entsprechend der ihm beilie genden Montageanleitung ...

Страница 18: ...im Display 0 System info und die grüne LED 3 signalisiert Betriebsbereitschaft Wird im Display nicht die Initialisierung 3 10 Sprache angeboten wurde das Schaltgerät bereits initialisiert In diesem Fall sind die eingestellten Parameter zu überprüfen oder die Werkseinstellungen herzustellten 3 11 Rücksetzen Nach der Rücksetzung zu den Werkseinstellungen startet selbsttätig die Initialisierung des S...

Страница 19: ...swählen und mit OK bestätigen Menü Datum Uhrzeit erscheint Datum Uhrzeit Die jeweils blinkende Ziffer in Datum und Uhrzeit einstellen und mit OK bestätigen Menü Produkttyp erscheint Produkttyp Auswählen zwischen Hybridhebeanlage Hebeanlage oder Pumpstation und mit OK bestätigen L LAuswahl hat Auswirkung darauf welche Einstellmöglichkeiten verfügbar sind Menü Anlagenvariante erscheint Abb 11 Pos Nr...

Страница 20: ...1 S3 Betrieb erscheint S1 S3 Betrieb Auswählen zwischen den Betriebsarten Die Betriebsart ist in den jeweili gen Herstellerunterlagen enthalten Nach der letzten Eingabe erscheint das Menü Wartungsintervall Wartungsintervall Eingabe des normativ vorgegebenen Wartungsintervalles Initialisierung abgeschlossen Schaltgerät ist betriebsbereit 5 2 Funktionskontrolle Funktionsprüfung gemäß der Einbau und ...

Страница 21: ...aste ESC das zuvor beschriebene Menü Datenübertragung angewählt werden Daten auslesen USB Stick anschließen Daten auslesen auswählen und mit OK bestätigen Eine Datei mit den Systemdaten wird auf den USB Stick gespeichert csv Update durchführen USB Stick anschließen Menü Datenübertragung wird angezeigt Nur möglich wenn sich eine entsprechende Datei hex auf dem USB Stick befindet Software Update aus...

Страница 22: ...dazu aufgefordert wird Batterie austauschen Anlage freischalten Sicherstellen dass Leitungen und elektrische Komponenten während den Arbeiten von der Spannungsversorgung getrennt sind Hauptschalter 1 am Schaltgerät in Position OFF bringen und das Gehäuse aufklappen Kabelbinder entfernen und beide Batterien 2 abstecken und durch neue ersetzen Neue Batterien mit Kabelbinder befestigen 1 2 Abb 12 ...

Страница 23: ...EM USB EXT INT PC SIGNAL GEBER Signaling device 信号传感器 LIN 12V B A GND 24V or RS485 or or bl LIN BUS bk w bl bk w bl bk gr or KLAPPE FLAP SONDE1 PROBE1 bk 5 T2 T1 T3 SONDE2 PROBE2 Alarm Ein1 Aus Ein2 bk rd gn PE bl N Brücke Bridge 电桥 Brücke Bridge 电桥 PUMPE 1 Pump 1 泵 400VAC 50Hz 1 2 3 4 5 PE 6 A2 NC 6 4 2 PUMPE 2 Pump 2 泵 400VAC 50Hz 1 2 3 4 5 PE 6 gn or or A2 NC 6 4 2 or NETZ Mains 电源 400VAC 50Hz ...

Страница 24: ...or L N PE 24V GND ALARM GND RG RxD RS TxD MODEM USB EXT INT PC SIGNAL GEBER Signaling device 信号传感器 LIN 12V B A GND 24V or RS485 or or bl LIN BUS bk w bl bk w bl bk gr or KLAPPE FLAP SONDE1 PROBE1 bk 5 T2 T1 T3 SONDE2 PROBE2 Alarm Ein1 Aus Ein2 bk rd gn PE bl N Brücke Bridge 电桥 Brücke Bridge 电桥 PUMPE 1 Pump 1 泵 400VAC 50Hz PE 6 9 A2 NC 6 4 2 PUMPE 2 Pump 2 泵 400VAC 50Hz gn or or A2 NC 6 4 2 or NETZ...

Страница 25: ...t 备用控制箱 or GND or or gn or L N PE 24V GND ALARM GND RG RxD RS TxD MODEM USB EXT INT PC SIGNAL GEBER Signaling device 信号传感器 LIN 12V B A GND 24V or RS485 or or bl LIN BUS bk w bl bk w bl bk gr or KLAPPE FLAP SONDE1 PROBE1 bk 5 T2 T1 T3 SONDE2 PROBE2 Alarm Ein1 Aus Ein2 bk rd gn PE bl N Brücke Bridge 电桥 Brücke Bridge 电桥 PUMPE 1 Pump 1 泵 400VAC 50Hz PE 6 9 A2 NC 6 4 2 PUMPE 2 Pump 2 泵 400VAC 50Hz gn o...

Страница 26: ...PE 2 Pump 2 泵 230VAC 50Hz 2 4 6 NCA2 3 PE N L PUMPE 1 Pump 1 泵 230VAC 50Hz Brücke Bridge 电桥 N bl PE gn rd bk Ein2 Aus Ein1 Alarm SONDE2 PROBE2 T3 T1 T2 3 bk SONDE1 PROBE1 KLAPPE FLAP or gr bk bl w bk bl w bk LIN BUS bl or RS485 or 24V GND A B 12V LIN PC INT EXT USB MODEM TxD RS RxD RG GND GND 24V PE N L or gn or or GND or Brücke Bridge 电桥 SIGNAL GEBER Signaling device 信号传感器 REDUNDANZ SCHALTGERÄT R...

Страница 27: ...der Anlage entspricht Hierzu 1 3 Steue rungstyp im Untermenü Information auswählen Die Ordnungszahl 3 des Menüpunktes steht in der obersten Zeile des Displays Die Tastenbelegung des Schaltgerätes wird im Abschnitt 5 1 Initialisierung durchführen erläutert Menüstruktur 0 Systeminfo 1 Informationen 1 1 Betriebsstunden 1 1 1 Gesamtlaufzeit h 0 999 999 9 1 1 2 Laufzeit Pumpe 1 h 0 0 9 999 9 1 1 3 Scha...

Страница 28: ...4 2 Nächste Wartung mm hh dd mm yy 1 5 Aktuelle Messwerte 1 5 1 Netz Strom A 0 99 9 1 5 2 Batterie Spannung V 0 99 9 1 5 3 Niveau mmWS 0 5000 1 5 4 Netz Spannung V 0 999 1 5 5 Temperatur C 9 99 1 5 6 Klappe Strom mA 0 999 1 6 Parameter 1 6 1 Einschaltverzögerung s 0 99 1 6 2 Nachlaufzeit s 0 99 1 6 3 Max Strom A 3 5 9 5 1 6 4 Min Strom A 0 5 2 5 1 6 5 Grenzlaufzahl 10min 1 99 1 6 6 Grenzlaufzeit m...

Страница 29: ...e s 0 99 1 6 17 Nachlaufzeit Klappe s 0 99 1 6 18 Max Strom Klappe mA 150 200 1 6 19 S1 S3 Pumpenbetrieb S1 Betrieb S3 Betrieb 2 Wartung 2 1 Handbetrieb 2 1 1 Pumpe 1 2 1 2 Potentialfreie Kontakte 2 1 3 Externer Signalgeber 2 1 4 Kommunikation 2 1 5 Pumpe 2 2 1 6 Klappe 2 1 7 AC Ausgang 2 1 8 DC Ausgang 2 2 Automatikbetrieb 2 2 Automatikbetrieb Ein Aus 2 3 SDS Selbstdiagnosesystem 2 3 1 Test Pumpe...

Страница 30: ... Drucksensor 3 Einstellungen 3 1 Parameter 3 1 1 Einschaltverzögerung s 0 99 3 1 2 Nachlaufzeit s 0 99 Zugangscode 1000 3 1 3 Max Strom A 3 5 9 5 3 1 4 Min Strom A 0 5 2 5 3 1 5 Grenzlaufzahl 10min 1 99 3 1 6 Grenzlaufzeit min 0 999 3 1 7 Lufteinperlung Offset mm 0 99 3 1 8 Höhe Stauglocke mm 0 999 3 1 9 SDS Selbstdiagnosesystem d 1 180 3 1 10 Messbereich Pegelsonde mm 0 9999 3 1 11 EIN 1 Niveau m...

Страница 31: ...2 2 Parameter laden 3 3 Datum Uhrzeit mm hh dd mm yy 3 4 Anlagenkonfiguration 3 5 Produkttyp 3 5 1 Pumpfix Ecolift XL Mono 3 5 2 Pumpfix Ecolift XL Duo 3 5 3 Hebeanlage Aqualift Mono 3 5 4 Hebeanlage Aqualift Duo 3 5 5 Pumpstation Aqualift Mono 3 5 6 Pumpstation Aqualift Duo 3 5 7 Hebeanlage XXL Mono 3 5 8 Hebeanlage XXL Duo 3 6 Anlagenvariante 3 6 1 1 Motorklappe 3 6 2 2 Motorklappen 3 6 5 F Comp...

Страница 32: ...6 19 Sonder Hebeanlage Duo 3 6 20 F XL Mono ATEX 3 6 21 S Mono 3 6 22 nicht belegt 3 6 23 F AP 501 Mono LW 800 3 6 24 F AP 501 Mono LW 1000 3 6 25 F ohne ATEX 3 6 26 S Schacht LW 600 Mono 3 6 27 S Schacht LW 1000 Mono 3 6 28 Sonder Pumpstation ohne ATEX 3 6 29 Sonder Pumpstation ATEX 3 6 30 F XL Duo ATEX 3 6 31 S Duo 3 6 32 nicht belegt 3 6 33 F AP 501 Duo LW 800 3 6 34 F AP 501 Duo LW 1000 3 6 35...

Страница 33: ...rösse 3 7 1 KTP500 230V 3 7 2 KTP1000 230V 3 7 3 SPF 1400 230V 3 7 4 SPF 1500 400V 3 7 5 SPF 3000 400V 3 7 6 SPF 4500 400V 3 7 7 SPF 5500 400V 3 7 8 1 9 kW 3 7 9 1 3 kW 3 7 10 Ama Porter 3 7 50 Sonderpumpe 3 7 11 230 V 2 5 4 A 3 7 12 230 V 4 6 3 A 3 7 13 230 V 6 3 10 A 3 7 14 400 V 2 5 4 A 3 7 15 400 V 4 6 3 A 3 7 16 400 V 6 3 10 A 3 7 17 400 V 9 12 A 3 7 25 STZ4400 3 7 26 STZ5200 ...

Страница 34: ...immer 3 8 4 Drucksensor Lufteinperlung 3 8 5 Pegelsonde 3 8 6 Pegelsonde Alarmschwimmer 3 8 7 Schwimmer 3 8 8 Schwimmer ohne Aus Niveau 3 9 Kommunikation 3 9 1 Direktverbindung 3 9 2 GSM Modem 3 9 2 1 Stationsname Zugangscode 1000 3 9 2 2 Eigene Nummer 3 9 2 3 Modemtyp 3 9 2 4 PIN 3 9 2 5 SMS Zentrale 3 9 2 6 SMS Ziel 1 3 9 2 7 SMS Ziel 2 3 9 2 8 SMS Ziel 3 3 9 2 9 Status 3 9 3 Modbus 3 9 3 1 Eins...

Страница 35: ...eutsch 3 10 2 English 3 10 3 Francais 3 10 4 Italiano 3 10 5 Nederlands 3 10 6 Polski 3 11 Rücksetzen 3 12 Experten Modus 3 12 1 Netz Einschaltverzögerung s 0 99 3 12 2 Batterieüberwachung ein aus 3 12 3 Automatische Alarmquittierung ein aus 3 12 4 TP Konstante 0 9999 3 12 5 Schwelle Batterie V 0 18 0 3 12 6 Drehfeld ein aus 3 12 7 Alternierender Betrieb ein aus 3 12 8 Zähler rücksetzen 3 12 9 AC ...

Страница 36: ... Grenze mm 5 99 3 12 16 Offset Drucksensor mmWS 30 30 3 12 17 Temperaturdrift 0 80 1 20 3 12 18 Verzögerung Druckabfallroutine s 0 99 3 12 19 Max Schaltspiele 1000 999 999 3 12 20 Max Schaltspiele Klappe x 5000 9900 3 12 21 Startverzögerung 3 12 22 Verzögerung Strommessung 3 12 23 Stromfaktor 3 12 24 Speicherung Druckabfall ein aus 0 Datenübertragung 0 1 Daten auslesen 0 2 Software Update 0 3 Para...

Страница 37: ...g Germany Our qualified local service partners will be happy to help with any technical problems you may have Visit www kessel de kundendienst to find your contact If necessary our Factory Customer Service provides support with services such as commissioning maintenance or general inspection throughout the DACH region other countries on request For information about handling and ordering see http ...

Страница 38: ...interval Screen text Bold type Particularly important or safety relevant information Italics Variant or additional information e g only applies for ATEX variant L L Technical information or instructions which must be paid particular attention 2 Safety The following symbols are used Icon Meaning Isolate device Observe the instructions for use CE marking Warning electricity WEEE icon product governe...

Страница 39: ...1 Approved activities on KESSEL systems Operating company Visual inspection inspection change of battery Technical expert is familiar with understands the operating manual Emptying cleaning inside functional check configuration of the control unit Technical specialist specialist craftsman acc to installation instructions and execution standards Installation replacement maintenance of components co...

Страница 40: ...tic components Touch the top hat rail before touching the components on the PCB This measure ensures that any electrostatic charges are balanced by you connecting your body to ground 2 3 Taking ATEX explosion protection into account The EX symbol identifies components and products that satisfy the ATEX requirement ATEX Guideline 2014 34 EU Only use ATEX system s and explosion proof components in p...

Страница 41: ...rol unit itself is NOT designed for installation in an EX zone All conversions or attachments that are carried out without the express and written permission of the manufacturer the use of non genuine spare parts and repairs carried out by companies or persons not approved by the manufacturer will lead to a loss of warranty 2 5 Product description The control unit is used for the automatic control...

Страница 42: ...AC DC 0 5 A Power contactor Switching contacts U 400V 10 4kW P2 50Hz Control elem power circuit Passive switches and buttons The control unit must be operated outside the potentially explosive area The necessary classification Group II Category 1 G appropriate operating equipment for a gas atmosphere Technical specification single barrier Level circuit in type of protection intrinsic safety Ex ia ...

Страница 43: ...230 V 50 Hz 400 V AC 50Hz Standby power 5W Potential free contact max 42 V DC 0 5 A Battery 2 x 9V 6LR614 Working temperature 0 40 C Protective rating IP 54 Protection class I Connection type Earthed coupling control unit Direct connection Type of fuse required Mono A C 16 C 16 C 16 C 20 Type of fuse required Duo A C 16 C 20 C 32 RCD 30 mA Protection class I Duo systems have two pumps with identic...

Страница 44: ... main switch Fig 14 on page 41 is in the OFF position Loosen the screws for the housing cover and open the housing cover Install the housing at the planned spot using all four attachment possibilities in the corners Take the ambient conditions into account There is a drilling template included in the scope of delivery Isolate the system Make sure that cables and electrical components are disconnec...

Страница 45: ...teed Mains cable 230V The control units are ready to plug in Installing the control unit for the redundant flap option When used with Pumpfix Ecolift XL in the version with two motor driven flaps connect the redundant connection in accordance withtheinstructions for the redundant control unit to the terminal block LIN BUS Fig 16 Connection overview for the mains cable 400V Source Connection cable ...

Страница 46: ... with 3 6 or 9 wires 3 wire cables are for the 230 V version the pump s of which can be connected by Phoenix contact plugs on the outside of the underside of the control unit For this reason no further information about this version is provided in this section For 9 wire cables double assignment of the phases in the wastewater pump Fig 17 is provided for PCB connections for the wastewater pump 1 3...

Страница 47: ...sensor is to be used to detect the filling level it has to be connected as follows Remove sealing cap Slide the air hose of the pressure sensor onto the connecting nipple of the pressure pipe connection 1 and fasten with the lock nut Always lay the air hose on a gradient With lengths over 10m or if the air hose has a counter slope use a compressor set for air bubbling see KESSEL accessories Fig 18...

Страница 48: ... plug out insert the M16 cable screw connection and fasten it using a counter nut Then pull the cable through and fasten the cover in place Mono float switch non ATEX Connect the ends of the float switch cables to the terminals shown ALARM ON OFF Probe2 On1 On2 Off Alarm Alarm On Off A Pump switched off Off B Switch pump on On D Alarm Fig 19 ...

Страница 49: ... 700_01 Duo float switch non ATEX Connect the ends of the float switch cables as shown in Fig 20 Alarm On1 Off On2 Probe2 On1 On2 Off Alarm Alarm On1 Off On2 A Pump switched off Off B Switch pump 1 on On1 Fig 20 C Switch pump 2 on On2 D Alarm ...

Страница 50: ...ables Fig 21 The connection of level sensors is identical for both Mono and Duo systems Overview of connections for the level sensor Wire colour Name on PCB Terminal colour Black Probe2 blue Red black Note When extending the level probe connection cable use the KESSEL terminal box art no 28799 Probe2 On1 On2 Off Alarm Mono Duo sw BK rt RD Fig 21 ...

Страница 51: ...the Zener Fig 22 The connection of level sensors is identical for both Mono and Duo systems Fig 22 rt RD 4 bl 3 bl HAZ sw BK Overview of connections for the level sensor Wire colour Name on Zener barrier Red plus 3 Black minus 4 Note When extending the level probe connection cable use the KESSEL terminal box art no 28799 ...

Страница 52: ... Routing the USB connection out option To make the USB socket on the PCB accessible without the housing having to be opened a USB housing socket with cable and connector for installation in the control unit housing can be ordered from KESSEL art no 28785 4 6 KESSEL TeleControl modem optional Install the KESSEL tele control modem art no 28792 according to the instal lation instructions enclosed wit...

Страница 53: ...cessful system test 0 System info appears on the display and the green LED 3 indicates that the unit is ready for operation If the display does not show initialisation 3 10 Language the control unit has already been initialised In this case the parameters set must be checked or the unit must be reset to the factory setting 3 11 Reset After the factory settings have been reset the control unit star...

Страница 54: ... select the language and confirm with OK Menu Date Time appears Date Time Set the respective flashing figure in date and time and confirm by pressing OK Menu Product type appears Product type Select between hybrid lifting station lifting station or pumping station and confirm by pressing OK L LThe selection affects which setting options are available Menu System variant appears Fig 26 Pos no Opera...

Страница 55: ...tion Select between the operating modes The operating mode can be found in the respective manufacturer s documents Following the last entry the menu Maintenance interval appears Maintenance interval Enter the maintenance interval specified in the standard Initialisation completed the control unit is ready for use 5 2 Functional check Carry out the functional check in accordance with the system s i...

Страница 56: ... can be used to return to the data transmission menu described above Read out data Connect USB flash drive Select Read out data and confirm with OK A file with the system data is stored on the USB flash drive csv Carry out update Connect the USB flash drive data transmission menu appears This is only possible if a respective file hex is on the USB flash drive Select Software update enter password ...

Страница 57: ...if this is indicated on the display To replace battery Isolate the system Make sure that cables and electrical components are disconnected from the power supply during work Move the main switch 1 on the control unit to the OFF position and open the housing Remove the cable ties take both batteries out 2 and replace them by new ones Fix the batteries in place using the cable ties 1 2 Fig 24 ...

Страница 58: ...D MODEM USB EXT INT PC SIGNAL GEBER Signaling device 信号传感器 LIN 12V B A GND 24V or RS485 or or bl LIN BUS bk w bl bk w bl bk gr or KLAPPE FLAP SONDE1 PROBE1 bk 5 T2 T1 T3 SONDE2 PROBE2 Alarm Ein1 Aus Ein2 bk rd gn PE bl N Brücke Bridge 电桥 Brücke Bridge 电桥 PUMPE 1 Pump 1 泵 400VAC 50Hz 1 2 3 4 5 PE 6 A2 NC 6 4 2 PUMPE 2 Pump 2 泵 400VAC 50Hz 1 2 3 4 5 PE 6 gn or or A2 NC 6 4 2 or NETZ Mains 电源 400VAC ...

Страница 59: ...gn or L N PE 24V GND ALARM GND RG RxD RS TxD MODEM USB EXT INT PC SIGNAL GEBER Signaling device 信号传感器 LIN 12V B A GND 24V or RS485 or or bl LIN BUS bk w bl bk w bl bk gr or KLAPPE FLAP SONDE1 PROBE1 bk 5 T2 T1 T3 SONDE2 PROBE2 Alarm Ein1 Aus Ein2 bk rd gn PE bl N Brücke Bridge 电桥 Brücke Bridge 电桥 PUMPE 1 Pump 1 泵 400VAC 50Hz PE 6 9 A2 NC 6 4 2 PUMPE 2 Pump 2 泵 400VAC 50Hz gn or or A2 NC 6 4 2 or N...

Страница 60: ...l unit 备用控制箱 or GND or or gn or L N PE 24V GND ALARM GND RG RxD RS TxD MODEM USB EXT INT PC SIGNAL GEBER Signaling device 信号传感器 LIN 12V B A GND 24V or RS485 or or bl LIN BUS bk w bl bk w bl bk gr or KLAPPE FLAP SONDE1 PROBE1 bk 5 T2 T1 T3 SONDE2 PROBE2 Alarm Ein1 Aus Ein2 bk rd gn PE bl N Brücke Bridge 电桥 Brücke Bridge 电桥 PUMPE 1 Pump 1 泵 400VAC 50Hz PE 6 9 A2 NC 6 4 2 PUMPE 2 Pump 2 泵 400VAC 50Hz...

Страница 61: ...L PUMPE 2 Pump 2 泵 230VAC 50Hz 2 4 6 NCA2 3 PE N L PUMPE 1 Pump 1 泵 230VAC 50Hz Brücke Bridge 电桥 N bl PE gn rd bk Ein2 Aus Ein1 Alarm SONDE2 PROBE2 T3 T1 T2 3 bk SONDE1 PROBE1 KLAPPE FLAP or gr bk bl w bk bl w bk LIN BUS bl or RS485 or 24V GND A B 12V LIN PC INT EXT USB MODEM TxD RS RxD RG GND GND 24V PE N L or gn or or GND or Brücke Bridge 电桥 SIGNAL GEBER Signaling device 信号传感器 REDUNDANZ SCHALTGE...

Страница 62: ...o this select 1 3 Control type in the sub menu Information The ordinal number 3 of the menu item is in the top line of the display The key assignment of the control unit is explained in 5 1 Carrying out initialisation Menu structure 0 System info 1 Informations 1 1 Hours of operation 1 1 1 Total running time h 0 999 999 9 1 1 2 Running time pump 1 h 0 0 9 999 9 1 1 3 Sw cycles pump 1 X 0 999 999 1...

Страница 63: ... Curr Measured values 1 5 1 Mains power A 0 99 9 1 5 2 Battery voltage V 0 99 9 1 5 3 Level mmWS 0 5000 1 5 4 Mains voltage V 0 999 1 5 5 Temperature C 9 99 1 5 6 Flap current mA 0 999 1 6 Parameters 1 6 1 On delay s 0 99 1 6 2 Run on time s 0 99 1 6 3 Max Current A 3 5 9 5 1 6 4 Min Current A 0 5 2 5 1 6 5 Limit number of operations 10min 1 99 1 6 6 Limit running time min 1 999 1 6 7 Air bubbling...

Страница 64: ...e flap s 0 99 1 6 18 Max current flap mA 150 200 1 6 19 S1 S3 Pump operation S1 operation S3 operation 2 Maintenance 2 1 Manual operation 2 1 1 Pump 1 2 1 2 Potential free contacts 2 1 3 Ext audible alarm 2 1 4 Communication 2 1 5 Pump 2 2 1 6 Flap 2 1 7 AC output 2 1 8 DC output 2 2 Automatic operation 2 2 Automatic operation On Off 2 3 SDS Self diagnosis system 2 3 1 Test pump 1 Test battery Tes...

Страница 65: ...on of pressure sensor 3 Settings 3 1 Parameters 3 1 1 On delay s 0 99 3 1 2 Run on time s 0 99 Access code 1000 3 1 3 Max Current A 3 5 9 5 3 1 4 Min Current A 0 5 2 5 3 1 5 Limit number of operations 10min 1 99 3 1 6 Limit running time min 0 999 3 1 7 Air bubbling offset mm 0 99 3 1 8 Height of immersion pipe mm 0 999 3 1 9 SDS Self diagnosis system d 1 180 3 1 10 Measuring range level probe mm 0...

Страница 66: ...e memory 3 2 1 Save parameters 3 2 2 Load parameters 3 3 Date Time mm hh dd mm yy 3 4 System configuration 3 5 Product type 3 5 1 Pumpfix Ecolift XL Mono 3 5 2 Pumpfix Ecolift XL Duo 3 5 3 Lifting station Aqualift Mono 3 5 4 Lifting station Aqualift Duo 3 5 5 Pumping station Aqualift Mono 3 5 6 Pumping station Aqualift Duo 3 6 System variant 3 6 1 1 motor driven flap 3 6 2 2 motor driven flaps 3 6...

Страница 67: ...o 3 6 19 Special lifting station Duo 3 6 20 F XL Mono ATEX 3 6 21 S Mono 3 6 22 not occupied 3 6 23 F AP 501 Mono LW 800 3 6 24 F AP 501 Mono LW 1000 3 6 25 F without ATEX 3 6 26 S inspection chamber LW 600 Mono 3 6 27 S inspection chamber LW 1000 Mono 3 6 28 Special pumping station without ATEX 3 6 29 Special pumping station ATEX 3 6 30 F XL Duo ATEX 3 6 31 S Duo 3 6 32 not occupied 3 6 33 F AP 5...

Страница 68: ...ial pumping station ATEX 3 7 Power rating 3 7 1 KTP500 230V 3 7 2 KTP1000 230V 3 7 3 SPF 1400 230V 3 7 4 SPF 1500 400V 3 7 5 SPF 3000 400V 3 7 6 SPF 4500 400V 3 7 7 SPF 5500 400V 3 7 8 1 9 kW 3 7 9 1 3 kW 3 7 10 Ama Porter 3 7 50 Special pump 3 7 11 230 V 2 5 4 A 3 7 12 230 V 4 6 3 A 3 7 13 230 V 6 3 10 A 3 7 14 400 V 2 5 4 A 3 7 15 400 V 4 6 3 A 3 7 16 400 V 6 3 10 A 3 7 17 400 V 9 12 A 3 7 25 ST...

Страница 69: ...r float switch alarm 3 8 4 Pressure sensor air bubbling 3 8 5 Level sensor 3 8 6 Level sensor float switch alarm 3 8 7 Float switch 3 8 8 Float switch without off level 3 9 Communication 3 9 1 Station name 3 9 2 Own number 3 9 3 Modem type 3 9 4 PIN 3 9 5 Text message Headquarters 3 9 6 Text message Destination 1 3 9 7 Text message Destination 2 3 9 8 Text message Destination 3 3 9 9 Status 3 10 L...

Страница 70: ...shold V 0 18 0 3 12 6 Rotary field on off 3 12 7 Alternating operation on off 3 12 8 Reset counter 3 12 9 AC output on off 3 12 10 DC output on off 3 12 11 Text message Interval weekly daily hourly 3 12 12 OPT fault det time s 0 30 3 12 13 OPT logics time s 0 30 3 12 14 dry run protection on off 3 12 15 Max pressure error mm 5 99 3 12 16 Offset pressure sensor mmWS 30 30 3 12 17 Temperature drift ...

Страница 71: ...700_01 3 12 20 Max Switching cycles flap x 5000 9900 3 12 21 Start delay 3 12 22 Delay in current measurement 3 12 23 Current factor 3 12 24 Save pressure loss on off 0 Data exchange 0 1 Read out data 0 2 Software update 0 3 Read in parameters ...

Страница 72: ...的服务 我们追求最高品质 始终坚 定不移地以可持续发展为重心 不仅涵盖产品制造 还涵盖产 品的长期运行 让您和您的财产得到长期保护 科赛尔排水设备 常熟 有限公司 江苏省常熟市虞山高新技术产业园 阳关大道55号 F 2 中国 邮编 215500 电话 0086 0512 8338 80000 传真 0086 0512 8338 8008 安装和操作手册 Comfort PLUS电控箱 010 700 01 目录 1 本手册说明 73 2 安全 73 3 技术数据 78 4 安装 79 5 初始操作 初始化 88 6 设备维护保养 91 7 配置菜单概述 97 ...

Страница 73: ... 插图中的步骤号 检查手动控制是否已激活 操作的前提 按 确定 操作步骤 系统准备好运行 操作结果 2 安全 交叉参考第2章 设置设备维护保养间隔 界面文本 粗体 尤为重要的或与安全相关的信息 斜体 配置或附加信息 如 仅适用于 ATEX配置 L L 必须格外注意的技术信息或说明 2 安全 使用了以下标志 标志 含义 将设备隔离 请遵守使用说明书 CE标志 触电警告 WEEE标志 表示受RoHS指南管辖的产品 使用前请接地 警告 警告存在人员危险 忽视该警告会导致重伤或死 亡 小心 警告存在人员和材料危险 忽视该警告会导 致人员重伤与材料损坏 ...

Страница 74: ...操作安全规定与危险物质条例或类似的国家法规适用 于该系统的运作 系统操作员必须 准备风险评估 识别并划分相应危险区 参加安全培训 防止未经授权人员使用系统 人士1 允许对KESSEL系统实施的措施 运营公司 目检 检查 更换电池 专家 熟悉并理解操作手册 电控箱的清空 清洁 内部 功能检 查 配置 专家 按安装说明书与执行标准操作的专业技 工 部件安装 更换与 维护 调试 持证电工 VDE 0105 按电气安全法规操作 电气安装 仅允许已满18岁的人员执行操作与装配作业 ...

Страница 75: ...换保险丝 F1 或电池 按照安装说明书与电路图连线 所有其它作业仅可由KESSEL客服部或KESSEL AG的服务合作伙伴 执行 处理静电部件时 请小心谨慎 请先触碰顶帽式导轨 再触碰PCB上的部件 这样可 将您的身体接地 从而确保任何静电得 到均衡 2 3 考虑ATEX 防爆 EX标志表示部件和产品满足ATEX要求 ATEX指南 2014 34 EU 请仅在潜在爆炸区使用ATEX系统与防爆部件 对于 潜在爆炸区域 需单独采取安全措施 按照有效的欧盟指令开展ATEX风险评估 并确定EX区域 检查提升泵和其余系统部件 包括附件 是否符合ATEX与确 定的EX区域的要求 检查电控箱是否适于同提升泵联用以及是否属于ATEX配置 如不确定 请参阅标准证书与技术规格 2 5 1 有关 ATEX设计的附加信息 ...

Страница 76: ...到启动 液位时 提升泵功能将激活 液位下降后 提升泵关闭功能将 自动运行 使用某些类型的泵时 可能需调整电机保护开关 4 2 连接 污水提升泵 电控箱本身不装在EX区 未经制造商书面明确批准就改装系统或在系统中安装附加装置 使用非原装备件以及安排未经制造商批准的公司或人士实施维修 均会导致保修失效 2 5 产品描述 电控箱用于自动控制各种不同的泵站与污水提升器 根据使用 的型号 连接230 V 安全插头 或400 V 终端 电源 我们 提供拥有不同开断容量 A 的电控箱 插图 27 功能部件 1 主开关 2 显示和控制面板 3 铭牌 4 电缆槽 连接 2 4 3 1 ...

Страница 77: ...TF1a TF2a TF1b TF2b端子 热输入Un 230V 输出电缆无源干接点 U 42 V AC DC 0 5 A 电源接触器 开关接点U 400V 10 4kW P2 50Hz 控制元件电源电路 无源 开关与按钮 电控箱必须在潜在爆炸区域外操作 还需满足以下分类标准 II组 1 G类适用于气体环境的设备 技术规格 单一防爆栅 液位电路 本安型Ex ia IIC 浮球开关端子 关闭 开启1 开启2 报警 液位探头端子 探头2 bk bl 最大值 Uo 28 V Io 93 mA Ro 300 Ω Po 0 65 W Co 0 083 µF Lo 16 mH Lo Ro 106 µH Ω 齐纳防爆栅MTL 7787 齐纳防爆栅欧盟认证证书 标准标志 II 1 GD Ex ia Ga IIC Ex ia Da IIIC 20 C Ta 60 C II 1 GD Ex ia Ga IIC...

Страница 78: ...10 A 2 5 4 0 A 4 0 6 3 A 6 3 10 A 重量 4 0 kg 3 8 kg 尺寸 LxWxD mm 380x280x130 额定电压 230 V 50 Hz 400 V AC 50Hz 待机功率 5W 无源干接点 最大42 V DC 0 5 A 电池 2 x 9V 6LR614 工作温度 0 40 C 保护等级 IP 54 防护等级 I 连接类型 接地联轴器 电控箱 直接连接 单泵系统需要的保险丝类型 A C 16 C 16 C 16 C 20 双泵系统需要的保险丝类型 A C 16 C 20 C 32 RCD 30 mA 防护等级 I 双泵系统包含两台技术参数完全相同的提升泵 各提升泵的电控箱的 电机保护开关 的耗电量不同 ...

Страница 79: ...件结尾提供了PCB的总连接图 拧紧扭矩见 插图 28 电缆槽连接扭矩 4 1 安装电控箱 L L主开关 第 页插图 1 位于关闭位置时 方可打开电控箱 插图 27 见第 页 76 拧松壳盖上的螺钉 打开壳盖 将外壳装在规定位置 固定四角 考虑环境条件 包装清单中包含开孔器 将系统隔离 确保电缆与电气部件在作业过程中与电源 断连 插图 28 电缆槽连接扭矩 19mm 15mm A 230V B B B B 19mm A 230V 1 1 2 2 4mm 3Nm 1 2mm 1Nm 3 3 ...

Страница 80: ...口连至终端线夹与主开关 按照接线图执行 电控箱壳盖内的 连接作业 拧紧电缆螺栓连接 确保密封 230 V电源电缆 电控箱已做好插入电源的准备 安装其他其余的控制单元 选配 与带双泵头的设备Pumpfix Ecolift XL联用时 按电控箱说 明书将端子连至端子排 LIN BUS 插图 29 400 V电源电缆连接概览 电源 连接电缆 导线类型 标签 连接名称 电源 5极 保护接地 黄色 绿色 PE 中性线 蓝色 N 相 L1 T1 相 L2 T2 相 L3 T3 5 PE N T1 T2 T3 ...

Страница 81: ...栓连接的相同方式连至 电源电缆 按接线图连接 L L本系统中的提升泵可分别使用3线 6线或9线电缆 3线电缆 用于230 V配置 该配置使用的提升泵可通过电控箱底面外部的Pho enix接触插头连接 因此 本节不提供有关该配置的其它信息 使用9线电缆时 污水提升泵中各相位的连接加倍 插图 30 污水提升泵的PCB连接 1 3 1 6 相 4 5 7 8 温度监测 TF1和TF2 PE 保护接地 TF1 温度监测连接 自动重置 TF2 温度监测连接 非自动重置 仅9线配置 必须将满足ATEX要求的系统连至端子排TF2 U1 V1 V2 W2 U2 W1 T1T2 6 9 T1T3 4 5 TF1 ATEX ATEX TF2 TF1 插图 30 ...

Страница 82: ...安装和操作手册 82 010 700_01 4 3 连接液位探测器 本文件结尾概述了PCB连接 压力传感器 可选 拆下密封盖 使用压力传感器检测液位需按以下步骤连接压力传感器 将压力传感器的空气管拧到压力管的螺纹接套上 1 用防松螺 母固定 保持装好的空气管有一定坡度 如果空气管长于10 m或有反向管路坡度 利用压缩机组去除气泡 见KSESSEL附件 插图 31 ...

Страница 83: ...操作手册 83 010 700_01 浮球开关 如果使用浮球开关检测液位 将密封插头拉出 插入M16电缆螺 栓连接 用埋头螺母将其固定 然后将电缆从螺栓连接中穿 过 并将盖子固定 单泵浮球开关 非ATEX型 将浮球开关电缆的两端连至图示端子 ALARM ON OFF Probe2 On1 On2 Off Alarm Alarm On Off A 提升泵关闭 关闭 B 提升泵开启 开启 D 报警 插图 32 ...

Страница 84: ...安装和操作手册 84 010 700_01 双泵浮球开关 非ATEX型 连接 插图 33 Alarm On1 Off On2 Probe2 On1 On2 Off Alarm Alarm On1 Off On2 A 提升泵关闭 关闭 B 提升泵1开启 开启1 插图 33 C 提升泵2开启 开启2 D 报警 ...

Страница 85: ... 85 010 700_01 连接液位传感器 单泵 双泵液位传感器 非ATEX型 连接 插图 34 单泵系统与双泵系统中的液位传感器的连接方式相同 液位传感器连接概览 电线颜色 PCB上的名称 端子颜色 黑色 探头2 蓝色 红色 黑色 注意 延伸液位探头连接电缆时 请使用 KESSEL接线盒 产品编号 28799 Probe2 On1 On2 Off Alarm Mono Duo sw BK rt RD 插图 34 ...

Страница 86: ...安装和操作手册 86 010 700_01 单泵 双泵ATEX液位传感器 将ATEX液位传感器电缆的两端连至 插图 35 单泵系统与双泵系统中的液位传感器的连接方式相同 插图 35 rt RD 4 bl 3 bl HAZ sw BK 液位传感器连接概览 电线颜色 齐纳防爆栅上的 名称 红色 3 黑色 4 注意 延伸液位探头连接电缆时 请使用KESSEL 接线盒 产品编号 28799 ...

Страница 87: ...按照冗余电控箱随附的说明书将该 阀片连至冗余电控箱 4 5 在外部连接USB 可选 为使PCB上的USB活接头在外壳未打开的情况下可够到 可向 KESSEL订购USB外壳活接头以及用于将该活接头装在电控箱的 电缆与连接器 产品编号 28785 4 6 KESSEL 远程控制调制解调器 可选 按照KESSEL远程控制调制解调器随附的安装说明书安装KES SEL远程控制调制解调器 产品编号 28792 4 7 其它可能的连接 外部信号发生器 报警 可选 Kessel附件 产品编号 20162 相关连接说明 见 6 3 4 6 3 400 V系统的接线图 无源干接点 可选 附件 有多种形式 如报警灯 产品编号 97715 ...

Страница 88: ...测试备用电池的电压 菜单项目 3 10 语言 显示 开启 关闭 按初始操作部分的描述操作 将主开关 1 调到位置 I 开启 关闭 系统成功通过测试后 显示屏显示 0 系统信 息 绿色LED 3 发光 指示系统已准备好运行 如果显示屏不显示初始化 3 10 语言 则说明电控箱已进 行初始化 这种情况下 必须检查参数设置或必须将电控箱重 置为出厂设置 3 11 重置 重置为出厂设置后 电控箱自 动开始初始化 请知悉 重置为出厂设置时 设备维护保养间 隔计数器的读数不变 1 2 3 4 5 插图 36 故障显示 读取消息 一旦产生触发任何消息的状态 例如 提升泵故 障 污水液位达到报警液位 报警LED 5 将发 光 显示屏可能显示纯文本故障消息 关闭声音 报警 短暂按下报警键 4 确认报警 长按报警键 4 5秒 确认报警 消息消失 设备 运行记录书记录确认操作 ...

Страница 89: ...计会生成以下输入 语言 日期 时间 产品类型 系统配置 额定功率 S1 S3运行 设备维护保养间隔 语言 按 确定 用光标键选择语言 然后按 确定 日期 时间 菜单显示 日期 时间 设置日期和时间 设置的数字将闪烁 然后按 确定 进 行确认 产品类型 菜单显示 产品类型 选择混合动力污水提升器 污水提升器或提升泵站 然后按 确定 L L选择的项目会影响可用的设置选项 系统配置 菜单显示 插图 39 位置编号 操作键 1 向上鼓动 2 确定 键 3 向下滚动 4 ESC 返回k 4 ...

Страница 90: ... 010 700_01 系统配置 选择产品配置 可在相应制造商文件中查找产品配置 L L选择的项目会影响可用的设置选项 S1 S3运行 菜单显示 S1 S3运行 选择运行模式 可在相应制造商文件中查找运行模式 完成 最后一项输入后 设备维护保养间隔 菜单显示 设备维护保养间隔 输入标准规定的设备维护保养间隔 初始化完成 电控箱可用 5 2 功能检查 按照系统安装与维护说明书以及所有附加部件的安装与维护说明 书执行功能检查 ...

Страница 91: ...检测到 然 后 显示屏将显示含以下选项的数据传输菜单 0 1 读出数据 0 2 软件更新 0 3 读入参数 显示 0 系统信息 菜单后 可按ESC键 返回上述数据传输菜 单 读出数据 连接USB闪存盘 选择 读出数据 然后按 确定 包含系统数据的文 件 csv 存储在USB闪存盘 中 更新 连接USB闪存盘后 显示屏显示数据 传输菜单 仅当USB闪存盘中有相应的文件 hex 时 方可实施该操作 选择 软件更新 输入密码 然后按 确定 更新过程将 自行进行 仅需按显示屏显示 的对话操作 读入参数 连接USB闪存盘后 显示屏显示数据 传输菜单 仅当USB闪存盘中有相应的文件 csv 时 方可实施该操作 选择 读入参数 输入密码 然后按 确定 更新过程将 自行进行 仅需按显示屏显示 的对话操作 ...

Страница 92: ...安装和操作手册 92 010 700_01 6 2 更换电池 Comfort PLUS电控箱装有电池 以备断电时使用 如果显示屏 指示需更换电池 必须更换电池 更换电池 将系统隔离 确保电缆与电气部件在作业过程中与电源 断连 将电控箱上的主开关 1 调到关闭位置 然后打开外壳 解开电缆绑带 取出电池 2 换上新电池 用电缆绑带固定电池 1 2 插图 37 ...

Страница 93: ... PC SIGNAL GEBER Signaling device 信号传感器 LIN 12V B A GND 24V or RS485 or or bl LIN BUS bk w bl bk w bl bk gr or KLAPPE FLAP SONDE1 PROBE1 bk 5 T2 T1 T3 SONDE2 PROBE2 Alarm Ein1 Aus Ein2 bk rd gn PE bl N Brücke Bridge 电桥 Brücke Bridge 电桥 PUMPE 1 Pump 1 泵 400VAC 50Hz 1 2 3 4 5 PE 6 A2 NC 6 4 2 PUMPE 2 Pump 2 泵 400VAC 50Hz 1 2 3 4 5 PE 6 gn or or A2 NC 6 4 2 or NETZ Mains 电源 400VAC 50Hz POTENTIAL FREI...

Страница 94: ...24V GND ALARM GND RG RxD RS TxD MODEM USB EXT INT PC SIGNAL GEBER Signaling device 信号传感器 LIN 12V B A GND 24V or RS485 or or bl LIN BUS bk w bl bk w bl bk gr or KLAPPE FLAP SONDE1 PROBE1 bk 5 T2 T1 T3 SONDE2 PROBE2 Alarm Ein1 Aus Ein2 bk rd gn PE bl N Brücke Bridge 电桥 Brücke Bridge 电桥 PUMPE 1 Pump 1 泵 400VAC 50Hz PE 6 9 A2 NC 6 4 2 PUMPE 2 Pump 2 泵 400VAC 50Hz gn or or A2 NC 6 4 2 or NETZ Mains 电源 ...

Страница 95: ... or or gn or L N PE 24V GND ALARM GND RG RxD RS TxD MODEM USB EXT INT PC SIGNAL GEBER Signaling device 信号传感器 LIN 12V B A GND 24V or RS485 or or bl LIN BUS bk w bl bk w bl bk gr or KLAPPE FLAP SONDE1 PROBE1 bk 5 T2 T1 T3 SONDE2 PROBE2 Alarm Ein1 Aus Ein2 bk rd gn PE bl N Brücke Bridge 电桥 Brücke Bridge 电桥 PUMPE 1 Pump 1 泵 400VAC 50Hz PE 6 9 A2 NC 6 4 2 PUMPE 2 Pump 2 泵 400VAC 50Hz gn or or A2 NC 6 4...

Страница 96: ...230VAC 50Hz 2 4 6 NCA2 3 PE N L PUMPE 1 Pump 1 泵 230VAC 50Hz Brücke Bridge 电桥 N bl PE gn rd bk Ein2 Aus Ein1 Alarm SONDE2 PROBE2 T3 T1 T2 3 bk SONDE1 PROBE1 KLAPPE FLAP or gr bk bl w bk bl w bk LIN BUS bl or RS485 or 24V GND A B 12V LIN PC INT EXT USB MODEM TxD RS RxD RG GND GND 24V PE N L or gn or or GND or Brücke Bridge 电桥 SIGNAL GEBER Signaling device 信号传感器 REDUNDANZ SCHALTGERÄT Redundancy Cont...

Страница 97: ...配 如需检查 选择 信息 子菜单中的 1 3 控制类型 菜单的序号 3 显示在显示屏的顶部 5 1 实施初始 化 5 1 实施初始化 菜单结构 0 系统信息 1 信息 1 1 工作时长 1 1 1 总运行时长 h 0 999 999 9 1 1 2 提升泵1运行时长 h 0 0 9 999 9 1 1 3 提升泵1开关次数 X 0 999 999 1 1 4 断电 h 0 0 999 999 9 1 1 5 耗电量 kWh 0 0 999 999 9 1 1 6 提升泵2运行时长 h 0 0 9 999 9 1 1 7 提升泵2开关次数 X 0 999 999 1 1 8 倒灌期 h 0 0 9 999 9 插图 38 bzw Schwimmeranzeige 3 ...

Страница 98: ...日 时 分 1 5 当前 测量值 1 5 1 电源电流 A 0 99 9 1 5 2 电池电压 V 0 99 9 1 5 3 液位 mmWS 0 5000 1 5 4 电源电压 V 0 999 1 5 5 温度 C 9 99 1 5 6 阀片电流 mA 0 999 1 6 参数 1 6 1 开启延时 s 0 99 1 6 2 运行时间 s 0 99 1 6 3 最大 电流 A 3 5 9 5 1 6 4 最小 电流 A 0 5 2 5 1 6 5 工作次数限值 10min 1 99 1 6 6 运行时间限值 min 1 999 1 6 7 气泡偏移 mm 0 99 1 6 8 压力开关管的高度 mm 0 999 1 6 9 SDS自检系统 d 1 180 1 6 10 量程液位探头 mm 0 9999 ...

Страница 99: ... 99 1 6 17 阀片后运行时间 s 0 99 1 6 18 阀片最大电流 mA 150 200 1 6 19 提升泵S1 S3运行 S1运行 S3运行 2 设备维护保养 2 1 手动操作 2 1 1 提升泵1 2 1 2 无源干接点 2 1 3 外部声音报警 2 1 4 通信 2 1 5 提升泵2 2 1 6 阀片 2 1 7 交流输出 2 1 8 直流输出 2 2 自动运行 2 2 自动运行 开启 关闭 2 3 SDS自检系统 2 3 1 提升泵1检测 电池检测 提升泵2检测 阀片检测 正常 故障 2 4 设备维护保养到期日 2 4 1 上次设备维护保养日期 年 月 日 时 分 2 4 2 下次设备维护保养日期 年月日时分 2 5 设备维护保养完成 2 6 设备维护保养间隔 2 6 1 3个月 ...

Страница 100: ...运行时间 s 0 99 访问代码 1000 3 1 3 最大 电流 A 3 5 9 5 3 1 4 最小 电流 A 0 5 2 5 3 1 5 工作次数限值 10min 1 99 3 1 6 运行时间限值 min 0 999 3 1 7 气泡偏移 mm 0 99 3 1 8 压力开关管的高度 mm 0 999 3 1 9 SDS自检系统 d 1 180 3 1 10 量程液位探头 mm 0 9999 3 1 11 开启1液位 mm 0 5000 3 1 12 关闭1液位 mm 0 5000 3 1 13 报警液位 mm 0 5000 3 1 14 开启2液位 mm 0 5000 3 1 15 关闭2液位 mm 0 5000 3 1 16 阀片开启延时 s 0 99 3 1 17 阀片后运行时间 s 0 99 ...

Страница 101: ...时分 3 4 系统配置 3 5 产品类型 3 5 1 Pumpfix Ecolift XL 单泵 3 5 2 Pumpfix Ecolift XL 双泵 3 5 3 Aqualift单泵污水提升器 3 5 4 Aqualift双泵污水提升器 3 5 5 Aqualift单提升泵站 3 5 6 Aqualift双提升泵站 3 6 系统配置 3 6 1 单电机阀片 3 6 2 双电机阀片 3 6 5 F Compact 3 6 6 F 3 6 7 F XL 200 l 3 6 8 F XL 300 l 3 6 9 F XL 450 l 3 6 10 S underfloor 3 6 11 特殊单泵污水提升器 3 6 12 F Compact 双泵 3 6 13 F 双泵 ...

Страница 102: ... S 单泵 3 6 22 无 3 6 23 F AP 501 单泵 LW 800 3 6 24 F AP 501 单泵 LW 1000 3 6 25 F 非ATEX型 3 6 26 S检查井 LW 600 单泵 3 6 27 S检查井 LW 1000 单泵 3 6 28 特殊提升泵站 非ATEX型 3 6 29 特殊提升泵站 ATEX型 3 6 30 F XL 双泵 ATEX 3 6 31 S 双泵 3 6 32 无 3 6 33 F AP 501 双泵 LW 800 3 6 34 F AP 501 双泵 LW 1000 3 6 35 F 非ATEX型 3 6 36 S检查井 LW 600 双泵 3 6 37 S检查井 LW 1000 双泵 3 6 38 特殊提升泵站 非ATEX型 3 6 39 特殊提升泵站 ATEX型 ...

Страница 103: ... 6 SPF 4500 400V 3 7 7 SPF 5500 400V 3 7 8 1 9 kW 3 7 9 1 3 kW 3 7 10 Ama Porter 3 7 50 特殊提升泵 3 7 11 230 V 2 5 4 A 3 7 12 230 V 4 6 3 A 3 7 13 230 V 6 3 10 A 3 7 14 400 V 2 5 4 A 3 7 15 400 V 4 6 3 A 3 7 16 400 V 6 3 10 A 3 7 17 400 V 9 12 A 3 7 25 STZ4400 3 7 26 STZ5200 3 7 27 STZ7500 3 7 28 STZ11000 3 7 29 GTF GTK5200 3 7 50 特殊提升泵 ...

Страница 104: ... 鼓泡 3 8 5 液位传感器 3 8 6 液位传感器 浮球开关报警 3 8 7 浮球开关 3 8 8 无关闭液位的浮球开关 3 9 通信 3 9 1 站名 3 9 2 本机编号 3 9 3 调制调解器类型 3 9 4 PIN 3 9 5 文本信息 总部 3 9 6 文本信息 目的地1 3 9 7 文本信息 目的地2 3 9 8 文本信息 目的地3 3 9 9 状态 3 10 语言 3 10 1 德语 3 10 2 英语 3 10 3 法语 3 10 4 意大利语 3 10 5 荷兰语 3 10 6 波兰语 3 11 重置 3 12 专家模式 3 12 1 开机延时 s 0 99 ...

Страница 105: ...器 3 12 9 交流输出 开启 关闭 3 12 10 直流输出 开启 关闭 3 12 11 文本信息 间隔 每周 每日 每 小时 3 12 12 OPT故障检测时间 s 0 30 3 12 13 OPT逻辑时间 s 0 30 3 12 14 空运转保护 开启 关闭 3 12 15 最大压力错误 mm 5 99 3 12 16 偏移压力传感器 mmWS 30 30 3 12 17 温度漂移 0 80 1 20 3 12 18 常规压降延时 s 0 99 3 12 19 最大 开关次数 1000 999 999 3 12 20 最大 阀片开关次数 x 5000 9900 3 12 21 启动延时 3 12 22 当前测量延时 3 12 23 当前系数 3 12 24 保存压力损失 开启 关闭 ...

Страница 106: ...安装和操作手册 106 010 700_01 0 数据交换 0 1 读出数据 0 2 软件更新 0 3 读入参数 ...

Страница 107: ......

Страница 108: ......

Отзывы: