background image

English

-

Cleaning the filter and diesel tank. 

Remove the filter on the diesel circuit and replace it. 

Replace regularly (fig. ).

Empty the diesel tank.

Using the drainage bung (fig. 8), drain any impurities present 

into a container.

Rinse the tank with clean diesel and close the drainage hole. 

DESCALING 

The appliance must be descaled regularly to avoid the risk of 

calcium in the water building up in and blocking the water circuit 

and coil.

This should be done by an authorised technical service 

centre and will increase the efficiency of the heat genera

-

tor.

STORAGE

If the hot water generator is not used for long periods, unplug 

from the mains socket and protect parts which might be dam

-

aged  by  dust.  Empty  the  water  circuit  and  rinse  with  clean 

water.

When  used  again,  check  there  are  no  cracks  or  cuts  in  the 

feed pipe.

If you decide to stop using the hot water generator, you should 

render it inoperative by removing the electric power cable. Parts 

which might constitute a danger, especially to children playing 

with the appliance, should be made harmless. 

The hot water generator is classified as special waste. It must 

be taken apart and divided into uniform sections which should 

be disposed off according to legislation in force in the country 

concerned. 

Do not use the components removed as spare parts.

SCRAPPING

H.P. feed pipe l = .0 m

 

TECHNICAL CHARACTERISTICS 

0       0 - 0/

Boiler volume        l 

,9 

,0 

Min. flow rate        l/min. 

6

Max. flow rate       l/min. 

1

Working pressure   bar 

00-0

Water temp.         °C 

10° 

10°

Heat input             W 

00 

00

Heat output           kW 

88

Diesel tank            l  

18 

18

Weight  Kg 

10 

Noise level    Lp dB (A)  

69 

69 

STANDARD KIT

TROUBLESHOOTING

Problem 

The appliance does not work. 

Cause 

No voltage. 

Faulty cable or mains switch. 

Remedy

 

Make sure there is voltage. 

Contact the service centre. 

Problem

When the thermostat reaches the set temperature, the boiler 

does not come on. 

Cause 

No diesel. 

Clogged diesel filters. 

Remedy 

Check the level of diesel in the fuel tank. Check the state of 

cleanliness of the fuel intake circuit (presence of water). Replace 

the circuit filter. 

Problem 

Water not hot enough. 

Cause 

Thermostat calibration. 

Clogged filters. 

Boiler coil blocked with scale. 

Remedy 

Check. 

Clean diesel filters. 

Contact the service centre. 

Problem 

Excessive smoking from flue. 

Cause 

No diesel. 

Incorrect fuel. 

Fuel contaminated with impurities or water. 

Remedy 

Fill diesel tank. 

Clean diesel filters. Contact authorised service centre. 

Empty the tank and clean thoroughly. Clean the various diesel 

filters.

Содержание FIRE 30

Страница 1: ...FIREBOX BOILER MODELS 30 40 OPERATING MAINTENANCE MANUAL Read Safety Operating Instructions Before Commencing Operation...

Страница 2: ...ahl nicht auf Personen Tiere Steckdosen oder die Maschine selbst richten Achtung Funkengefahr Wassereinlauf Einschalten des Brenners Treibstoff Diesel Achtung Verbrennungsgefahr Erdung Wasserablauf Re...

Страница 3: ...2 Fig 7 Fig 8 Fig 5 Fig 6 Fig 3 Fig 4 A B...

Страница 4: ...appliance It is an integral part of the product itself Read the warnings and instructions contained in this booklet carefully They provide important information on the safe use and maintenance of the...

Страница 5: ...as anonymous and potentially dangerous The main technical characteristics of the hot water generator are given on a plate applied to the front of the appliance fig 1 The user must ensure that the roo...

Страница 6: ...contact our technical service centre only 8 Do not clean the appliance with water jets 9 Use suitable personal protection gloves masks etc 10 The appliance must never be left unattended when in func...

Страница 7: ...ded into uniform sections which should be disposed off according to legislation in force in the country concerned Do not use the components removed as spare parts SCRAPPING H P feed pipe l 3 0 m TECHN...

Страница 8: ...230 240 50 0 3 300 175 max 2500 max 3 0 9 8 69 83 92 203 79x75x92 31x29 5x36 2 kW Thermal capacity 360 1260 95 333 18 4 8 5 8 1 53 67 30 140 86 284 Power supply v Hz kW Absorbed power W FIRE 40 230 24...

Страница 9: ...l to large heavy duty equipment and offer customized design build services We also warehouse and ship a comprehensive range of spare parts for your convenience For more information on your product to...

Отзывы: