ROUTINE MAINTENANCE TO BE PERFORMED BY THE USER
Check power cable, pipes, hose and high pressure connectors
– Before each use.
First oil change in high pressure pump
– After 50 hours
Subsequent oil changes in high pressure pump
– Every 500 hours
Change and clean fuel filters
– Every 100 hours
Clean fuel tank
– Every 100 hours
Clean water filter
– Every 50 hours
ROUTINE MAINTENANCE TO BE PERFORMED BY A TRAINED SERVICE TECHNICIAN
Clean coil on boiler
– Every 200 hours
Descale coil on boiler
– Every 300 hours
Clean fuel pump
– Every 200 hours
Change fuel nozzle
– Every 200 hours
Regulate electrodes
– Every 200 hours
Change electrodes
– Every 500 hours
Change seals on H.P. pump
– Every 500 hours
Change lance nozzle
– Every 200 hours
Calibrate and check the safety devices
– Once a year
TROUBLE SHOOTING
Trouble
Possible Cause
Remedy
Switch is turned on
but cleaner doesn’t
start.
Faulty electric connection
Check the mains voltage
Thermal protection has tripped
Reset (if it trips again, return to Kerrick or trained
technician for servicing)
No water jet
or
Leakage from high
pressure water
circuit
or
After 30
seconds water
cleaner stops (DS
versions only)
Faulty water circuit connection
Check it
Clogged water filter
Clean it
Mains tap turned off
Turn it on
Detergent tap turned on
Turn it off
IMPORTANT
:
These intervals refer to normal working conditions. For heavy use decrease the interval for each job.
For maintenance and/or repairs, use only original spare parts which offer the greatest characteristics of quality and
reliability. Failure to use original spare parts absolves the manufacturer from all liability and transfers it to the