Kerrick D 1012P4 M Скачать руководство пользователя страница 10

 

10 

 

Safety & Operating Manual  
Runner Hot Water Pressure Cleaner 

ROUTINE MAINTENANCE TO BE PERFORMED BY THE USER

 

  Check power cable, pipes, hose and high pressure connectors 

– Before each use. 

  First oil change in high pressure pump 

– After 50 hours 

  Subsequent oil changes in high pressure pump 

– Every 500 hours 

  Change and clean fuel filters 

– Every 100 hours 

  Clean fuel tank 

– Every 100 hours 

  Clean water filter 

– Every 50 hours 

 

ROUTINE MAINTENANCE TO BE PERFORMED BY A TRAINED SERVICE TECHNICIAN 

  Clean coil on boiler 

– Every 200 hours 

  Descale coil on boiler 

– Every 300 hours 

  Clean fuel pump 

– Every 200 hours 

  Change fuel nozzle 

– Every 200 hours 

  Regulate electrodes 

– Every 200 hours 

  Change electrodes 

– Every 500 hours 

  Change seals on H.P. pump 

– Every 500 hours 

  Change lance nozzle 

– Every 200 hours 

  Calibrate and check the safety devices 

– Once a year 

 

 
 
TROUBLE SHOOTING 
 

 

 

Trouble 

Possible Cause 

Remedy 

Switch is turned on 
but cleaner doesn’t 
start. 

Faulty electric connection 

Check the mains voltage 

Thermal protection has tripped 

Reset (if it trips again, return to Kerrick or trained 
technician for servicing) 

No water jet 

or 

Leakage from high 
pressure water 
circuit 

or 

After 30 

seconds water 
cleaner stops (DS 
versions only)  

Faulty water circuit connection 

Check it 

Clogged water filter 

Clean it 

Mains tap turned off 

Turn it on 

Detergent tap turned on 

Turn it off 

IMPORTANT

:  

 

These intervals refer to normal working conditions. For heavy use decrease the interval for each job.  

 

For maintenance and/or repairs, use only original spare parts which offer the greatest characteristics of quality and 
reliability. Failure to use original spare parts absolves the manufacturer from all liability and transfers it to the 

person carrying out the operation. 

Содержание D 1012P4 M

Страница 1: ...TY AND OPERATING MANUAL RUNNER HOT WATER ELECTRIC PRESSURE CLEANER D 1309P M D 1012P4 M D 1310P4 M D 1813P T D 1813P4 T D 1915P4 T D 2017P4 T Read Safety Operating Instructions Before Commencing Opera...

Страница 2: ...out of the pressure jet ALWAYS wear protective goggles and suitable protective clothing when operating the appliance Non slip rubber footwear must be worn when operating the machine If the machine fai...

Страница 3: ...ut in rain or freezing conditions DO NOT use if water pipes have frozen or if temperatures fall below zero without taking special precautions Putting acids solvents or highly corrosive materials throu...

Страница 4: ...uel may cause damage to the fuel pump 2 Filling the Detergent Tank i It is recommended that high quality liquid detergents having an alkaline pH be used Avoid the use of acid based detergents or solve...

Страница 5: ...upply voltage must be New Zealand 420v 50Hz or Australia 400v 50Hz three phase iii Power supply should be protected by a 15amp fuse for all single phase units iv The use of extension cords is not reco...

Страница 6: ...only for at least 30 seconds to cool down the boiler 3 After using with detergent flush out the intake circuit Place the detergent suction hose fig 9 in a tank of clean water and let the pump run for...

Страница 7: ...lance and spray the dirty surface with the diluted product working from bottom to top 3 Let it react for a few minutes 4 Rinse the whole surface well from top to bottom with hot or cold water at high...

Страница 8: ...from the socket 9 For high pressure cleaners provided with water tank the detergent solution prepared as described in the point 3 must be poured directly into the tank PERIODS OF INACTIVITY If the mac...

Страница 9: ...e the drain screw and pour fresh oil in through the filling cap on top fig 15A until it reaches the level indicated on the sight glass fig 15B Use only SAE 15 W40 oil CLEANING THE FUEL FILTER AND TANK...

Страница 10: ...Every 200 hours Calibrate and check the safety devices Once a year TROUBLE SHOOTING Trouble Possible Cause Remedy Switch is turned on but cleaner doesn t start Faulty electric connection Check the ma...

Страница 11: ...improper size Clean strainer and replace with correct size if required Dirty or worn valves Clean and replace as required Detergent intake device on the lance is turned on Turn it off When the lance...

Страница 12: ...12 Safety Operating Manual Runner Hot Water Pressure Cleaner...

Страница 13: ...services We also warehouse and ship a comprehensive range of spare parts for your convenience For more information on your product to book in a service or repair or to order spare parts give Kerrick...