background image

14

ENGLISH

TROUBLESHOOTING

Should problems arise during operation or ignition, use this chart to determine the cause and the 

proper steps to take. Be sure to unplug heater and allow to cool completely before taking correc-

tive measures.

PROBLEM

CAUSE

SOLUTION

POWER LAMP FAILS

TO TURN ON

- Disconnected power plug

- Incorrect wiring

- Circuit board malfunction

- Plug into 230V AC outlet

- Consult your dealer

- Consult your dealer

NO IGNITION

- Out of fuel

- Clogged air fi lter

-  Use of inferior kerosene (paraf-

fi n)

- Incorrect wiring

-  Circuit board, ignition heater or 

fuel pump malfunction

- Refuel 

- Clean air fi lter

-  Remove fuel and refuel using 

fresh, clear kerosene  (paraffi  n)

- Consult your dealer

- Consult your dealer

ODOR

- Clogged air fi lter

- Spilled kerosene (paraffi  n)

-  Use of inferior kerosene (paraf-

fi n)

- Clean air fi lter

-  Wipe off  any kerosene (paraffi  n) 

spills from fuel sub tank, remov-

able fuel tank and drip tray

-  Remove fuel and refuel using 

fresh, water-clear kerosene 

(paraffi  n)

EXTINGUISHED

AFTER IGNITION

- Excessive room temperature

- Oxygen shortage in room

- Tip-over switch activated

-  Water in fuel acceptance fi tting

- Out of fuel

-  Flame sensor or fuel pump 

malfunction

- High limit switch activated

- Allow room to cool

-  Open doors and windows to 

ventilate room thoroughly

- Reignite

-  Remove fuel and refuel using 

fresh, water-clear kerosene 

(paraffi  n)

- Refuel

- Consult your dealer

-  Clean circulation fan cover, 

remove any obstructions

POOR COMBUSTION/

NOISY COMBUSTION

- Clogged air fi lter

-  Loose screws or incorrect as-

sembly

- Incorrect wiring

-   Circuit board or fuel pump 

malfunction

- Altitude too high

- Clean air fi lter.

- Consult your dealer.

- Consult your dealer.

- Consult your dealer.

- Consult your dealer.

If the corrective measures outlined above do not solve the problem, please consult your dealer.

Should problems arise during operation or ignition, use this chart to determine the cause and the 

proper steps to take. Be sure to unplug heater and allow to cool completely before taking correc-

tive measures.

16

Содержание LC-54

Страница 1: ...LC 54 Type A Fan Heater Inverter Laser Clean EN INSTRUCTIONS MANUAL GR...

Страница 2: ...____________14 __________________________15 ______________________________16 _____________________________17 GR _______________________ 16 _________________________16 _____________________________16 _...

Страница 3: ...l be reached quickly In such cases to avoid overheating the area the heater must be turned off frequently or doors opened to other areas of the house or windows to the outside opened to cool the area...

Страница 4: ...l in room is insufficient Heater shuts off automatically Fuel Indicator constant Fuel tank empty Only 10 minutes burning time remaining Digital indicator shows the remaining burning time in minutes Yo...

Страница 5: ...ll packing materials for future storage of your heater 4 When positioning your heater for use keep it away from walls and all other materials as illus trated below 5 The floor should be firm and compl...

Страница 6: ...six or seven times Once ow begins it is no longer necessary to squeeze the bulb 4 Check the removable tank fuel gauge while lling the tank Stop lling by loosening the switch button on top of the pump...

Страница 7: ...the hours using the key hour and the minutes using the key min and the day using the key extension day set Press once to increase the value by one step When you hold down the key the value will conti...

Страница 8: ...VE function allows you to limit the temperature When this function is activated the heater will automatically switch off when the room temperature exceeds the set temperarure by 3 C Subsequently when...

Страница 9: ...will take some time after the re fill before the heater is completely ready for use again The childproof lock can be used to prevent children accidentally changing the heater settings When the heater...

Страница 10: ...highest setting again TURNING OFF HEATER While heater is burning press power switch to OFF position This will extinguish heater and ON OFF Lamp on the indicator panel will go out down heater NEVER Tur...

Страница 11: ...played program Use the adjustment keys to set the hour at which the heater must ignite Press the adjusment key to increase the hour and the key to decrease the hour Press extension day set to select t...

Страница 12: ...day of its source is displayed in the display Press extension day set to select The display shows COPYING THE SETTING FROM ONE DAY TO ANOTHER 11 ENGLISH AUTOMATIC CLEANING MODE When the heater has bee...

Страница 13: ...11 ENGLISH AUTOMATIC CLEANING MODE When the heater has been burning continuously for two hours at its highest setting the burner will automatically start an autoclean procedure The display will show t...

Страница 14: ...r Too little ventilation Ventilate better 50 MESSAGE Digital Indicator MESSAGE MEAING WHAT TO DO Temperature within the heater too high Cool down and re ignite Power interrupted You can re ignite the...

Страница 15: ...NOTE Never wipe with cloth it will clogfilters further 2 Clean Fan Cover Using a vacuum cleaner remove any dust from the fan cover at the back of the heater 3 Clean Fuel Acceptance Fitting When dirt o...

Страница 16: ...ip tray Remove fuel and refuel using fresh water clear kerosene paraffin EXTINGUISHED AFTER IGNITION Excessive room temperature Oxygen shortage in room Tip over switch activated Water in fuel acceptan...

Страница 17: ...able in the European Union and other European countries with separate collection systems This symbol on the product or on its packaging indicates that this product shall not be treated as household wa...

Страница 18: ...16 LC 54 Type A 15 7 50 0 23 W 550 x 327 5 x 445 mm 18...

Страница 19: ...e Indicator constant The operation is in Save mode operation Ventilation Indicator flashing Oxygen level in room is insufficient Heater shuts off automatically Fuel Indicator constant Fuel tank empty...

Страница 20: ...and all packing materials for future storage of your heater 4 When positioning your heater for use keep it away from walls and all other materials as illus trated below 5 The floor should be firm and...

Страница 21: ...19 1 2 3 1 2 3 4 5 6 7 19 1 2 3 1 2 3 4 5 6 7 21...

Страница 22: ...20 1 hour min 2 hour min 1 10 5 1 2 20 1 hour min 2 hour min 1 10 5 1 2 4 hour min extension day set 10 5 1 2 3 20 1 hour min 2 hour min 1 10 5 1 2 20 1 hour min 2 hour min 1 10 5 1 2 22...

Страница 23: ...22 1 hour min t 2 min hour 3 20o C SAVE SAVE 3oC SAVE SAVE SAVE SAVE SAVE 1 2 20oC SAVE SAVE SAVE SAVE 23...

Страница 24: ...23 key lock 3 key lock 3 VENT VENT Service 10 Extension 90 90 10 2 FUEL button once more FUEL 24 60 60...

Страница 25: ...24 5 OFF ON OFF 90 69 I 80 20 7 10 Motion Motion 10 Motion Motion 25...

Страница 26: ...OFF 150 10 50 50 Hr ON OFF P1 ON 6 30 6 30 6 30 6 30 6 30 10 00 9 00 P1 OFF 8 45 8 45 8 45 8 45 8 45 23 00 23 00 P2 ON 12 00 15 00 18 00 12 00 12 00 P2 OFF 14 00 23 00 23 00 14 00 14 00 P3 ON 18 00 18...

Страница 27: ...24 5 OFF ON OFF 90 69 I C extension day P1 P2 P3 Copy C C C C 27...

Страница 28: ...24 5 OFF ON OFF 90 69 I C 1 SET 3 3 TIMER TIMER P COPY C C C 28...

Страница 29: ...SET 3 TIMER D On Off off on 29 24 5 OFF ON OFF 90 69 I B D...

Страница 30: ...Digital Indicator MESSAGE MEANING Service Service OFF 32oC 65 FUEL VENT SERVICE Service SERVICE OFF 32 C SERVICE SERVICE 50 25 MESSAGE Digital Indicator MESSAGE MEANING Service Service OFF 32oC 65 FU...

Страница 31: ...eplacing NOTE Never wipe with cloth it will clogfilters further 2 Clean Fan Cover Using a vacuum cleaner remove any dust from the fan cover at the back of the heater 3 Clean Fuel Acceptance Fitting Wh...

Страница 32: ...Service Service Service Service Service Service Service 27 Service Service Service Service Service Service Service Service Service 27 Service Service Service Service Service Service Service Service S...

Страница 33: ...28 1 2 3 4 Fuel acceptance tting 33...

Страница 34: ...29 LC 43G 6 12242 Inverter 1 x x 437x435x315 x x 480x475x355 11 5 13 LC 54 Type A 445x550x327 5 500x600x370 13 5 14 5 34...

Страница 35: ...30 NOTES 35...

Страница 36: ...86 400 Fax 30 210 5316515 6 122 42 210 53 86 400 210 5316515 SERVICE A D M 6 122 42 302105386300 8 542 48 302310308018 A D M S A Athens 6 Kifissou Av Egaleo P C 122 42 Telephone 302105386300 Thessalon...

Страница 37: ...122 42 210 5386300 FAX 210 5317655 1 24 2 3 4 5 6 7 8 9 10 11 12 1999 44 EC 13 14 15 16 service SERVICE SERIAL NUMBER 6 122 42 210 53 86 400 10 546 44 2310 85 61 00 New 10 15 Printed in Japan 8664001...