MBC-BAPS-e-1820
23
P3 Pro
tri
Not documented
CoUnt
Not documented
rESEt
Reset weighing scale to factory setting
SEtGrA
Not documented
* default setting
10 Error messages
Display
Description
Zero range exceeded
(on start-up or when pressing the
key)
•
Load on weighing pan
•
Excess load, during zero setting of weighing scale
•
Incorrect adjusting process
•
Fault on load cell
Value outside the A/D changer range
•
Damaged weighing cell
•
Damaged electronics
Lack of possibility of zero point initiation
•
Damaged / overloaded measuring cell
•
The objects are located on the platform / have contact
with it
•
Unremoved transportation protection
•
Main Board damaged
Should other error messages occur, switch balance off and then on again. If the error
message remains inform manufacturer.
Содержание TMBC 15K2DEM-A