background image

21 

 

OSF-5-BA-e-1510 

Trouble shooting 

 

 
 

Electrical system 

 

Problem 

Possible causes 

The  lighting  unit  (if  fitted)  cannot  be 
switched on 

The power cable is either not connected or 
not connected correctly 
The bulb is not fitted 
The bulb has blown 
The fuse has blown 
The brightness control is set to the lowest 
level 

The bulb has blown 

The wrong bulb has been used 
The input voltage was too high 

The bulb flickers 

The bulb is not correctly fitted 
The lamp is worn out 

The bulb brightness is not sufficient 

The wrong bulb has been used 
The input voltage is too low 

 
 
 
 

Optical unit 

 

Problem 

Possible causes 

You can see two images 

The interpupillary distance is not set 
correctly 
The magnifications of the eyepieces do not 
match 

There is dirt in the visual field 

There is dirt on the object being observed 

There is dirt on the eyepiece surface 

The image is unclear 

There is dirt on the objective surface 

The focus wheels are jammed 

The torque of the focus wheels is set too 
high 

The  microscope  head  slips  down 
while you are viewing the object 

The torque of the focus wheels is set too low 

Eyes get tired easily 

The dioptre adjustment is not correct 
The brightness adjustment is not correct 

 

 

In

te

rn

ati

o

n

al

e

 T

e

m

p

e

ra

tu

K

o

rr

e

ktu

Ta

b

e

ll

e

 f

ü

°B

ri

(%

 Zu

cke

rg

ra

d

ie

n

t)

D

as

 E

rg

e

b

n

is

 u

m

 d

ie

 f

o

lg

e

n

d

e

n

 W

e

rte

 ko

rr

ig

ie

re

n

 (

Re

fr

akto

m

e

te

m

u

ss

 ko

rr

e

kt 

ka

li

b

ri

e

rt 

se

in

 b

e

i 2

0

°C

)

Re

ad

in

°B

ri

x

0.

0

5.

0

10

.0

15

.0

20

.0

25

.0

30

.0

35

.0

40

.0

45

.0

50

.0

55

.0

60

.0

65

.0

70

.0

75

.0

80

.0

85

.0

10

.0

-0

.5

3

-0

.5

6

-0

.5

9

-0

.6

2

-0

.6

5

-0

.6

7

-0

.6

9

-0

.7

1

-0

.7

2

-0

.7

3

-0

.7

4

-0

.7

5

-0

.7

5

-0

.7

5

-0

.7

5

-0

.7

5

-0

.7

4

-0

.7

3

11

.0

-0

.4

9

-0

.5

2

-0

.5

4

-0

.5

7

-0

.5

9

-0

.6

1

-0

.6

3

-0

.6

4

-0

.6

5

-0

.6

6

-0

.6

7

-0

.6

8

-0

.6

8

-0

.6

8

-0

.6

8

-0

.6

7

-0

.6

7

-0

.6

6

12

.0

-0

.4

4

-0

.4

7

-0

.4

9

-0

.5

1

-0

.5

3

-0

.5

5

-0

.5

6

-0

.5

7

-0

.5

8

-0

.5

9

-0

.6

0

-0

.6

0

-0

.6

1

-0

.6

1

-0

.6

0

-0

.6

0

-0

.6

0

-0

.5

9

13

.0

-0

.4

0

-0

.4

1

-0

.4

3

-0

.4

5

-0

.4

7

-0

.4

8

-0

.5

0

-0

.5

1

-0

.5

2

-0

.5

2

-0

.5

3

-0

.5

3

-0

.5

3

-0

.5

3

-0

.5

3

-0

.5

3

-0

.5

2

-0

.5

2

14

.0

-0

.3

4

-0

.3

6

-0

.3

8

-0

.3

9

-0

.4

0

-0

.4

2

-0

.4

3

-0

.4

4

-0

.4

4

-0

.4

5

-0

.4

5

-0

.4

6

-0

.4

6

-0

.4

6

-0

.4

6

-0

.4

5

-0

.4

5

-0

.4

4

15

.0

-0

.2

9

-0

.3

1

-0

.3

2

-0

.3

3

-0

.3

4

-0

.3

5

-0

.3

6

-0

.3

7

-0

.3

7

-0

.3

8

-0

.3

8

-0

.3

8

-0

.3

8

-0

.3

8

-0

.3

8

-0

.3

8

-0

.3

7

-0

.3

7

16

.0

-0

.2

4

-0

.2

5

-0

.2

6

-0

.2

7

-0

.2

8

-0

.2

8

-0

.2

9

-0

.3

0

-0

.3

0

-0

.3

0

-0

.3

1

-0

.3

1

-0

.3

1

-0

.3

1

-0

.3

1

-0

.3

0

-0

.3

0

-0

.3

0

17

.0

-0

.1

8

-0

.1

9

-0

.2

0

-0

.2

0

-0

.2

1

-0

.2

1

-0

.2

2

-0

.2

2

-0

.2

3

-0

.2

3

-0

.2

3

-0

.2

3

-0

.2

3

-0

.2

3

-0

.2

3

-0

.2

3

-0

.2

3

-0

.2

2

18

.0

-0

.1

2

-0

.1

3

-0

.1

3

-0

.1

4

-0

.1

4

-0

.1

4

-0

.1

5

-0

.1

5

-0

.1

5

-0

.1

5

-0

.1

5

-0

.1

5

-0

.1

5

-0

.1

5

-0

.1

5

-0

.1

5

-0

.1

5

-0

.1

5

19

.0

-0

.0

6

-0

.0

6

-0

.0

7

-0

.0

7

-0

.0

7

-0

.0

7

-0

.0

7

-0

.0

8

-0

.0

8

-0

.0

8

-0

.0

8

-0

.0

8

-0

.0

8

-0

.0

8

-0

.0

8

-0

.0

8

-0

.0

8

-0

.0

7

20

.0

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

0.

00

21

.0

0.

06

0.

07

0.

07

0.

07

0.

07

0.

07

0.

08

0.

08

0.

08

0.

08

0.

08

0.

08

0.

08

0.

08

0.

08

0.

08

0.

08

0.

07

22

.0

0.

13

0.

14

0.

14

0.

14

0.

15

0.

15

0.

15

0.

15

0.

16

0.

16

0.

16

0.

16

0.

16

0.

16

0.

15

0.

15

0.

15

0.

15

23

.0

0.

20

0.

21

0.

21

0.

22

0.

22

0.

23

0.

23

0.

23

0.

23

0.

24

0.

24

0.

24

0.

24

0.

23

0.

23

0.

23

0.

23

0.

22

24

.0

0.

27

0.

28

0.

29

0.

29

0.

30

0.

30

0.

31

0.

31

0.

31

0.

32

0.

32

0.

32

0.

32

0.

31

0.

31

0.

31

0.

30

0.

30

25

.0

0.

34

0.

35

0.

36

0.

37

0.

38

0.

38

0.

39

0.

39

0.

40

0.

40

0.

40

0.

40

0.

40

0.

39

0.

39

0.

39

0.

38

0.

37

26

.0

0.

42

0.

43

0.

44

0.

45

0.

46

0.

46

0.

47

0.

47

0.

48

0.

48

0.

48

0.

48

0.

48

0.

47

0.

47

0.

46

0.

46

0.

46

27

.0

0.

50

0.

51

0.

52

0.

53

0.

54

0.

55

0.

55

0.

56

0.

56

0.

56

0.

56

0.

56

0.

56

0.

55

0.

55

0.

54

0.

53

0.

52

28

.0

0.

58

0.

59

0.

60

0.

61

0.

62

0.

63

0.

64

0.

64

0.

64

0.

65

0.

65

0.

64

0.

64

0.

64

0.

63

0.

62

0.

61

0.

60

29

.0

0.

66

0.

67

0.

68

0.

69

0.

70

0.

71

0.

72

0.

73

0.

73

0.

73

0.

73

0.

73

0.

72

0.

72

0.

71

0.

70

0.

69

0.

68

30

.0

0.

74

0.

75

0.

77

0.

78

0.

79

0.

80

0.

81

0.

81

0.

81

0.

82

0.

81

0.

81

0.

81

0.

80

0.

79

0.

78

0.

77

0.

75

Te

mp

era

tur 

°C

Содержание OSF 522

Страница 1: ...elei 1 D 72336 Balingen E mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com User instructions Stereo microscope KERN OSF 5 OSF 522 OSF 523 OSF 524 OSF 525...

Страница 2: ......

Страница 3: ...onality 11 5 1 Getting started 11 5 2 Adjust the interpupillary distance 11 5 3 Adjusting the magnification 11 5 4 Dioptre adjustment and focussing 12 5 5 Adjusting the stand 13 5 6 Using eye cups Hig...

Страница 4: ...of triggering an electric shock 1 2 Notes on the electrical system OSF 523 OSF 525 OSF 527 Before connecting to a mains power supply you must make sure that you are using the correct input voltage Th...

Страница 5: ...older must not be rotated back too far If you do this there is a risk that the microscope could tip over When the microscope is not being used you should fit the objective cap and cover the microscope...

Страница 6: ...and alcohol as these are highly flammable substances You must therefore keep it away from naked flames and electrical devices which can be switched on and off and only use it in well ventilated rooms...

Страница 7: ...OSF 5 BA e 1510 6 2 Nomenclature Using the OSF 527 as an example With lighting...

Страница 8: ...7 OSF 5 BA e 1510 Rear view...

Страница 9: ...on Model KERN Tube Eyepiece Field of view mm Objective Stand Illumination OSF 522 Binocular HSWF 10x 23 mm 23 1x 2x Pillar OSF 523 Binocular HSWF 10x 23 mm 23 1x 2x Pillar 3W LED reflected light 3W LE...

Страница 10: ...sier to operate the focus wheels or lighting control for example we recommend that you position the head with the tube connectors centrally to the front Ideally the holder and head are then parallel o...

Страница 11: ...OSF 5 BA e 1510 10 Assembled stereo zoom microscope...

Страница 12: ...ach time a different person uses the microscope the gap between the two eyepieces must be re adjusted While you are looking through the eyepieces use one hand to hold the righthand or lefthand prism h...

Страница 13: ...k through the righthand eyepiece without dioptre adjustment ring with the right eye and bring the object into focus by using the focus control dials 4 Now set the largest magnification 5 Once again st...

Страница 14: ...could occur if the objective lens and the object being observed should collide Height adjustment Fixing the microscope holder With a stereo microscope on a pillar stand the microscope head can be heig...

Страница 15: ...ed by the glasses symbol on the side They are also marked in the item description by an additional H example HSWF 10x 23 mm When fitting the eye cups make sure that the dioptre setting is not moved We...

Страница 16: ...e from the righthand side the lefthand switch 3 is for transmitted light and the righthand switch 4 is for reflected light You can also adjust the light intensity for both lighting units To do this th...

Страница 17: ...ighting unit Typical goose neck lighting unit Fitting a ring lighting unit As you can see in the figure on the left the ring lighting units have three screws which must be positioned such that they do...

Страница 18: ...s are available as accessories for these applications You just have to fit the dark field attachment in the recess in the middle of the stand base You must first remove the stand inlay which is fitted...

Страница 19: ...the figures show both versions each have two coaxially positioned adjustment wheels in the righthand rear corner of the table This means that you can move it in the x and y directions To fit this the...

Страница 20: ...ange a bulb Problems with the lighting unit would therefore in most cases be caused by defects in the electrical system If this is the case then our Technical Service will be able to help 5 11 Changin...

Страница 21: ...g OBB A6205 Pillar with 3W LED lighting Transmitted light and reflected light OZB A5101 For further stands please see the Kern Optics main catalogue from page 64 and please visit our website www kern...

Страница 22: ...ufficient The wrong bulb has been used The input voltage is too low Optical unit Problem Possible causes You can see two images The interpupillary distance is not set correctly The magnifications of t...

Страница 23: ...materials which you can dispose of at your local recycling centre Disposal of the storage box and device must be carried out by the operator in accordance with all national or regional laws in force...

Отзывы: