KERN CDS 100K0.5 Скачать руководство пользователя страница 22

10  Declaration of conformity 

 

 

KERN & Sohn GmbH 

D-72322 Balingen-Frommern 

Postfach 4052 

E-Mail: [email protected] 

Tel: 0049-[0]7433- 9933-0 

Fax: 0049-[0]7433-9933-149 

Internet: www.kern-sohn.de 

Declaration of conformity 

EC-Konformitätserklärung 

 

 

 

EC-Declaration of -Conformity 

EC-

 

Déclaration de conformité 

 

 

 

EC-Declaración de Conformidad 

EC-Dichiarazione di conformità 

 

 

 

EC-Conformiteitverklaring 

EC- Declaração de conformidade 

 

 

 

EC- Prohlášení o shode 

EC-

Deklaracja zgodności 

 

 

 

EC-

Заявление о соответствии 

 

Konformitäts-
erklärung 

Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, 
mit den nachstehenden Normen übereinstimmt. 

GB 

Declaration of 
conformity 

We hereby declare that the product to which this declaration refers conforms 
with the following standards.  

CZ 

Prohlášení o 
shode 

Tímto prohlašujeme, že výrobek, kterého se toto prohlášení týká, je v souladu 
s níže uvedenými normami. 

Declaración de 
conformidad 

Manifestamos en la presente que el producto al que se refiere esta 
declaración está de acuerdo con las normas siguientes 

Déclaration de 
conformité 

Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la 
présente déclaration, est conforme aux normes citées ci-après. 

Dichiarazione di 
conformitá 

Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si 
riferisce è conforme alle norme di seguito citate. 

NL 

Conformiteit-
verklaring 

Wij verklaren hiermede dat het product, waarop deze  verklaring betrekking 
heeft, met de hierna vermelde normen overeenstemt. 

Declaração de 
conformidade 

Declaramos por meio da presente que o produto no qual se refere esta 
declaração, corresponde às normas seguintes. 

PL 

Deklaracja 

zgodności 

Niniejszym oświadczamy, że produkt, którego niniejsze oświadczenie dotyczy, 

jest zgodny z poniższymi normami. 

RUS 

Заявление о 

соответствии 

Мы  заявляем,  что  продукт,  к  которому  относится  данная  декларация, 

соответствует перечисленным ниже нормам. 

 

Electronic Balance:  KERN CKE / CDS 

 

EU Directive 

Standards 

2004/108/EC 

EN 55011: 2009+A1:2010 (Limit class B) 
EN 55022: 2010/AC:2011(Limit class B) 
EN 55024: 2010 
EN 61000-3-2: 2006-04+A1: 2009 + A2: 2009 
EN 61000-3-3: 2008 
OIML R 76-1:2006 
EN 45501: 1992-10+AC: 1993-08  

2006/95/EC 

EN 60950 

2011/65/EU 

EN 50581:2012 

 

 

 

Signatur 

Signature  

 

 

 

Datum 

Date

 

17.07.2014 

Ort der Ausstellung  

Place of issue

 

72336 Balingen

 

 

Albert Sauter 
KERN & Sohn GmbH 

 

 

 

 

Geschäftsführer 

Managing director

 

 

 

 

 

 

KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0 
Fax +49-[0]7433/9933-149, E-Mail: [email protected], Internet: www.kern-sohn.com

 

 

 

 

CKE/CDS-BA-e-1526 

22 

Содержание CDS 100K0.5

Страница 1: ...H Ziegelei 1 D 72336 Balingen email info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating Manual Counting balances KERN CKE CDS Version 2 6 01 2015 GB C...

Страница 2: ...lacing 11 6 3 Mains connection 11 6 4 Battery operation CKE 12 6 5 Connection of peripheral devices 12 6 6 Initial Commissioning 12 6 7 Adjustment 13 6 8 Adjusting see chapter 7 2 1 13 6 9 Verificatio...

Страница 3: ...tare key and press the ON OFF key Let go of the tare key Using the automatic reference optimization OPT the counting accuracy is automatically increased when applying up to 100 items Factory settings...

Страница 4: ...3 0 3 6 kg 2 4 5 6 kg Recommended adjustment weight F1 not added 300 g 2 kg 2 kg 1 kg 5 kg Appropriate for verification max 80 rel non condensing Stabilization time typical 3 sec Allowable ambient te...

Страница 5: ...7 8 kg 5 10 15 16 kg 5 10 15 16 kg Recommended adjustment weight F1 not added 5 kg 2 kg 10 kg 5 kg 10 kg 5 kg Appropriate for verification max 80 rel non condensing Stabilization time typical 3 sec A...

Страница 6: ...kg 20 30 50 60 kg 20 30 50 60 kg Recommended adjustment weight F1 not added 20 kg 10 kg 50 kg 50 kg Appropriate for verification max 80 rel non condensing Stabilization time typical 3 sec Allowable a...

Страница 7: ...t point kg 1 2 4 2 5 10 15 2 5 10 15 16 10 15 20 30 10 15 20 30 Recommended adjustment weight F1 not added 2 kg 2 kg 10 kg 5 kg 10 kg 5 kg 20 kg 10 kg 20 kg 10 kg Appropriate for verification max 80 r...

Страница 8: ...36 20 30 50 60 20 50 100 Recommended adjustment weight F1 not added 20 kg 10 kg 50 kg 50 kg 50 kg Appropriate for verification max 80 rel non condensing Stabilization time typical 3 sec Allowable amb...

Страница 9: ...in explosive environment The serial version is not explosion protected The structure of the balance may not be modified This may lead to incorrect weighing results safety related faults and destructio...

Страница 10: ...ing immediately and the appliance itself when unpacking for possible visible damage In case of visible damage have the damage verified by the messenger s signature Do not alter goods or packaging and...

Страница 11: ...n of air humidity on the appliance may occur if a cold appliance is taken to a considerably warmer environment In this case acclimatize the disconnected appliance for ca 2 hours at room temperature Av...

Страница 12: ...tical value for operational safety this will be indicated in the display with the BATT LOW information 6 5 Connection of peripheral devices Before connecting or disconnecting of additional devices pri...

Страница 13: ...warming up time of ca 15 minutes is recommended for stabilization 6 9 Verification General introduction According to EU directive 90 384 EEC balances must be officially verified if they are used as f...

Страница 14: ...nce using 10 parts Generate reference using 20 parts In mode menu YES function Switchover pcs g In menu Mode function Print out weighing result Display icon Significance OVERLOAD Overload Weighing ran...

Страница 15: ...7 2 Operation 7 2 1 Adjusting 7 2 2 Speed 7 2 3 Auto Off CKE CDS BA e 1526 15...

Страница 16: ...CKE CDS BA e 1526 16...

Страница 17: ...o select the menu point Backlight auto and confirm by pressing the YES button The background illumination will be switched off automatically 10 sec after having reached a stable weighing value 7 2 5 S...

Страница 18: ...ground Baud rate The MODE key is used to set the Baud rate used for the transfer of measured values In the following example the baud rate is set to 4800 baud Setting Baud rate KERN CKE Display 1 Swit...

Страница 19: ...f When AUTOPRINT PC is active the current weighing values will be sent continuously via the RS 232 data interface Data output and remote control commands Remote control commands transferred as ASCII c...

Страница 20: ...e to their size or shape can be weighed with the help of the underfloor weighing facility Proceed as follows Switch off balance Turn over the balance and in doing so take care that the weighing plate...

Страница 21: ...case of an error in the program process briefly turn off the balance and disconnect from power supply The weighing process must then be restarted from the beginning Help Fault Possible cause The displ...

Страница 22: ...duit auquel se rapporte la pr sente d claration est conforme aux normes cit es ci apr s I Dichiarazione di conformit Dichiariamo con ci che il prodotto al quale la presente dichiarazione si riferisce...

Отзывы: