15 

 

OZL-45R-BA-e-1510 

5.8  Using external illumination units 

 
If, when using a microscope in its standard version, the lighting is not suitable for the 
application, then it often makes sense to fit an external lighting unit to overcome this 
problem. 
 
The lighting units which are suitable for devices of the OZL-45R series, are goose 
neck lighting units 

(see figure)

. These are available as LED as well as halogen 

versions and also have an on/off switch or different controller. 
 

 

  

 

Typical goose neck lighting unit 
 
 
Using goose neck lighting units 

 

Depending on the requirements, a goose neck lighting unit is placed next to, in front 
of or behind the microscope. For halogen lighting units, the light source is in the 
housing of the unit and is emitted through one or several optical fibre cables. For 
LED units, on the other hand, it us usually at the end of the cable.  
These cables are flexible and therefore offer a large number of positioning options, 
so that the object being observed is perfectly illuminated. 
 
 

5.9  Changing the bulb 

 
LED 

 

The devices in the OZL-45R series are fitted with LED bulbs. 
Due  to  the  long  service  life  of  an  LED  lighting  system,  for  these  microscopes  it  will 
not be necessary to simply change a bulb. 
Problems with the lighting unit would therefore, in most cases, be caused by defects 
in the electrical system. If this is the case, then our Technical Service will be able to 
help. 
 

 

Содержание OZL 456

Страница 1: ...RN Sohn GmbH Ziegelei 1 D 72336 Balingen E mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com User instructions Stereo zoom microscope KERN OZL 45R OZL 456...

Страница 2: ......

Страница 3: ...7 4 Assembly 8 5 Operation and functionality 10 5 1 Getting started 10 5 2 Adjusting the interpupillary distance 10 5 3 Adjusting the magnification 10 5 4 Dioptre adjustment and focussing 11 5 5 Adjus...

Страница 4: ...l parts in the base of the device must not be tampered with as in this area there is an additional risk of triggering an electric shock 1 2 Notes on the electrical system Before connecting to a mains...

Страница 5: ...gid smooth horizontal surface When the microscope is not being used you should fit the objective cap and cover the microscope with the enclosed dust protective cover If the eyepieces are being stored...

Страница 6: ...s these are highly flammable substances You must therefore keep it away from naked flames and electrical devices which can be switched on and off and only use it in well ventilated rooms However organ...

Страница 7: ...OZL 45R BA e 1510 6 2 Nomenclature...

Страница 8: ...e angled at 45 Interpupillary distance 55 75 mm Dioptre adjustment On both sides Packaging dimensions WxDxH 345x320x470 mm Standard configuration Model KERN Tube Eyepiece Field of view mm Objective Zo...

Страница 9: ...ctors so that you can then fit the eyepieces When doing this please be particularly careful that you do not touch the optical lenses with your fingers and that no dust enters the apertures You should...

Страница 10: ...9 OZL 45R BA e 1510 Assembled stereo zoom microscope...

Страница 11: ...ieces must be re adjusted While you are looking through the eyepieces use one hand to hold the righthand or lefthand prism housing firmly By rotating outwards or inwards you can either increase or red...

Страница 12: ...ough the right eyepiece with the right eye and bring the object into focus by using the focus control dials 5 Now set the largest possible zoom factor 6 Once again still only looking through the right...

Страница 13: ...the other wheel Depending on the direction of the turn the torque will be increased or decreased On one hand this function can help to make it easier to adjust the focus and on the other hand it can p...

Страница 14: ...ied by the glasses symbol on the side They are also marked in the item description by an additional H example HSWF 10x 23 mm When fitting the eye cups make sure that the dioptre setting is not moved W...

Страница 15: ...reflected light is on the right rear corner The reflected light is provided by an LED ring lighting unit which is fitted directly under the objective and is connected to the objective Furthermore you...

Страница 16: ...is placed next to in front of or behind the microscope For halogen lighting units the light source is in the housing of the unit and is emitted through one or several optical fibre cables For LED unit...

Страница 17: ...75x 62 5x 28 125x 187 5x 37 5x 255x Field of view mm 15 8 2 4 31 5 4 8 10 5 1 6 7 9 1 2 Working distance 113 mm 220 mm 50 mm 35 mm 7 Features Model outfit Kern model Order number OZL 456 Eyepieces HWF...

Страница 18: ...sufficient The wrong bulb has been used The input voltage is too low Optical unit Problem Possible causes You can see two images The interpupillary distance is not set correctly The magnifications of...

Страница 19: ...y materials which you can dispose of at your local recycling centre Disposal of the storage box and device must be carried out by the operator in accordance with all national or regional laws in force...

Отзывы: