5. Operative range and determined applica-
tion

The loor saw KDF-800E was manufactured for the purpose of cut

-

ting to a maximum depth of 320 mm in concrete, brickwork or similar 
building materials. Any application other than the ones described are 
to be considered illicit.

According to illustrations and information given in this manual, we 
reserve the right of technical changes.

6. Transport

To push the loor saw use the telescoping handlebars, but before

doing so make sure that the bars have been tightened with the help 

of the ring screws. For lifting with a crane use the jack rings.

(without blade) jack rings

(with mounted blade) jack rings

handlebars
ring screws

a
b
c
d

6.1  Removing the electric motor

To ill gasoline and oil at the engine read the corresponding chapter 

at the manual.

Floor saw

Disconnect the connector of the belt guard by pulling it vertically up-
wards together with the cover cover. (A)

Loosen the nut on the threaded rod, which connects the console 
plate to the low feed. Now pull the threaded rod back out of the fran-
king. (B)

Tilt the motor with the console plate as far as it is possible. You 
should now be able to pull the drive belt from the belt pulley towards 
you. (C)

Lift the motor and the console plate out of the machine. (D)

The motor is installed in reverse order. (E)

Содержание KDF 700-7,5E

Страница 1: ...Operating manual Floor saw KDF 700 7 5E KDF 800 7 5E...

Страница 2: ...oduction This loor saw KDF 700E is the result of permanent product deve lopment What makes this product outstanding are reliable opera tion easy handling and high mobility due to the application of ne...

Страница 3: ...correct sequence of work is kept and also to prevent damage or destruction of the machine and other parts Text passages emphasised in this manner contain important infor mation for safe machine opera...

Страница 4: ...ntains of the instructions of assembly and disassembly as well as the conditions of putting into operation and maintenance as given by the manufacturer The loor saw may be operated and maintained only...

Страница 5: ...idance tool for the detection of underground cabling pipework For the operation of the loor saw the local regulations of safety and accident prevention must be absolutely noted The blade guard should...

Страница 6: ...ne No Power 7 5 kW 7 5 kW Engine type 400V 50Hz 16A 400V 50Hz 16A Speed at the primary shaft 1350 u min 1500 u min Weight without blade guard 135kg 297 6lbs 135kg 297 6lbs Blade diameter max 800mm max...

Страница 7: ...manual 4 2 General plan Guiding device Front blade guard Rear blade guard Water connection with tap Handle bars Depth adjustment Switch box 16A Belt guard Cover plate Mounting saw blade 1 2 3 4 5 6 7...

Страница 8: ...the ring screws For lifting with a crane use the jack rings without blade jack rings with mounted blade jack rings handlebars ring screws a b c d 6 1 Removing the electric motor To ill gasoline and o...

Страница 9: ...1 Connection of water hoses and cables The cool water connection is done with a Gardena connection Use clean water only For the electric connection you need a 16A CCE cable min 5x2mm cable length 25m...

Страница 10: ...have become blue or lost segments should never be used 7 3 Mounting the blade guard cover Before commencing a job one should have both the blade guard and the cover of the blade free lange on tighten...

Страница 11: ...re that the emergency stop is pulled out Manipulate the lever of the brake that the loor saw cannot move To start the engine read the corresponding chapter at the manual In case the direction is wrong...

Страница 12: ...immediately 8 6 Stop cutting Lift the saw blade out of the cut close the ball valve at the water tank activate the brake and turn the switch at the engine off read the corresponding chapter at the en...

Страница 13: ...fore servicing Be certain that the carriage cannot move down The following maintenance work should be held Clean the loor saw after operation before each use control electric plug in connections and c...

Страница 14: ...g the hexagon nut on the threaded rod the motor together with the console plate can be swiveled forward and the drive belt pulled from the pulleys After winding the new belt the motor is brought into...

Страница 15: ...ble or switch defect change defect part Fuse for the main power line defect change fuse Emergency stop is active Pull it out Reversing Star Delta switch is not in 0 position Put the knob in 0 position...

Страница 16: ...Seite page 16 KDF 700E 800E Floor saw Operating manual...

Страница 17: ...von Ersatz teilen bedienen Sie sich bitte der nachfolgenden Ersatzteilliste Zur weiteren Information dienen die dazugeh rigen Zeichnungen Der Einbau und oder die Verwendung nicht durch uns gelieferte...

Страница 18: ...el AC Copper CU Polyamid PA Machine Steel sheet AC Cast iron FT Aluminium AL 13 Declaration of conformity We hereby declare that this machine conforms with the following standards Designation of the m...