V1.0 | 24.03.2020 |Page 4
6.2 Setting connections
• The Wanesy™ Wave enclosure must be mounted on any concrete pedestal, concrete
wall or any non-flammable surface (UL94-V0).
• It must not be mounted on a flammable surface.
In order to connect the Wanesy™ Wave, you just have to plug the product on the micro-B USB
power supply.
The Wanesy™ Wave is powered by micro-B USB 5Vdc ±5% / 1A.
Please check accessories preconized by Kerlink.
Operating temperature range: -20°C to +55°C
Humidity: 5% to 95%
Altitude max. < 2000m
6.3 First connection
The LEDs are used to indicate the following behavior:
LED 2
LED 1
Item
Specification
LED 1
(Green):
ON: USB Power connected
OFF: USB Power disconnected
LED 2
(Red):
ON: LoRaWAN join request sent, waiting for accept.
OFF: During boot or LoRaWAN network joined.