Regarding the power supply, the following equipments can be used:
•
End-Span or Mid-Span at least a 15W PoE (Power over Ethernet) (not included)
6.5
Assembly instruction for sealing the connectors
Pay attention to the gasket when screwing the 2 caps : if you screw too hard, it
may twist.
Here is an example of what is OK and what is not.
If you use a torque wrench, the tightening torque should be 1.6 Nm maximum
To avoid environmental aggression (moisture, pollution, etc.) and ensure their
reliability, use a self-amalgamating tape on the N connector as show below :
The Ethernet cable is not provided and must consist of two RJ45 T 568A (or 568B) plugs on
each side.
KERLINK recommends using a cable with the following characteristics:
•
Category: 6A
•
Shielding: STP (U/FTP) or SSTP (S/FTP)
•
Section conductors: AWG26
•
External jacket: LSZH or PUR
•
Maximum length: 100 meters
•
Cable gland 6.6-8.6mm.
Operating temperature range: -40°C to +60°C
Altitude max. < 2000m / hygrometry 95% non-condensing