2-8

MAT 6V/15V/25V/36V/ 022300

2.6.4

LOAD CONNECTION, LOCAL ERROR SENSING

The DC OUTPUT connector is located on the back of chassis, and is designated A6-J2 in the
schematic. Table 2-4 and Figure 2-2 provide the function and location of DC OUTPUT connector
pins.

NOTE: The sense terminals MUST be configured for either local sensing (as follows) or

remote  sensing  (see  PAR.  2.6.5)  for  the  MAT  Power  Module  to  operate.  If  left
unconnected the unit will automatically isolate the load and shut down.

For  Local sensing  connect  Output  Terminal  1    to Sense Terminal  1,  and  Output  Terminal  2 to
Sense Terminal 2 at the DC Output connector (see Figure 2-5).  

FIGURE 2-5.    LOAD CONNECTIONS, LOCAL SENSING

2.6.5

LOAD CONNECTION WITH REMOTE ERROR SENSING

The  MAT series of  Power Modules can operate  with sensing  external to the Module. Sensing
should be with a twisted wire pair to reduce noise. The sensing wires must be connected as fol-
lows: Output terminal 1 to Sense Terminal 1 and Output Terminal 2 to Sense Terminal 2, each at
the load (see Figure 2-6). Refer to Table 2-4 and Figure 2-2 for DC Output connector pin func-
tions and locations.

When the MAT Power Module is connected for remote error sensing (in the voltage mode), a sit-
uation might occur where the output capacitor C14 must be supplemented to achieve optimum
performance. If oscillations are observed at the output terminals or at the load, the load should
be decoupled with another high quality capacitor of a value equal to or greater than C14.

FIGURE 2-6.    LOAD CONNECTIONS, REMOTE SENSING

Содержание MAT FULL RACK 15V

Страница 1: ...t revision for your par ticular model and serial number 3 The contents of this manual are protected by copyright Reproduction of any part can be made only with the specific written permission of Kepco...

Страница 2: ......

Страница 3: ...USA Importer s Name and Address Type of Equipment Component Power Supply Model No PRODUCT MODEL NUMBER Year of Manufacture I the undersigned declare that the product specified above when used in conj...

Страница 4: ...wire grounded mains connection See wiring section of this manual for complete electrical wiring instructions EN61010 1 2001 Cl 6 10 1 4 This power supply has secondary output circuits that are conside...

Страница 5: ...connection on the product s rear panel To reconfigure the product input for other nominal mains voltages as listed herein the product must be modified by a trained service technician The PROTECTIVE E...

Страница 6: ...2 9 2 8 1 Example 1 Full Scale Voltage Check 2 10 2 8 2 Example 2 Full Scale Current Check 2 11 2 8 3 Example 3 To Reset the Power Module 2 12 SECTION 3 OPERATION 3 1 General 3 1 3 2 Introduction To...

Страница 7: ...dance With Frequency For A Voltage Source And A Current Source 2 7 2 5 Load Connections Local Sensing 2 8 2 6 Load Connections Remote Sensing 2 8 3 1 Top Cover Access Points 3 1 3 2 MAT Power Module C...

Страница 8: ...9 2 1 Internal Controls Accessible Through Top Cover 2 1 2 2 Front Control MAT Power Module 2 2 2 3 Rear Terminations MAT Power Module 2 3 2 4 DC Output Connector Pin Functions 2 3 2 5 Input And Outpu...

Страница 9: ...oard control of the MAT via the IEEE 1118 bus b Controller Model TMA 4882 27 is free standing and allows host computers designed for RS232 or IEEE 488 bus communication to control the MAT via the IEEE...

Страница 10: ...1 2 MAT FULL RACK 022300 FIGURE 1 1 REMOTELY CONTROLLED POWER SUPPLY CONFIGURATIONS USING KEPCO PRODUCTS 3040800...

Страница 11: ...ater Time 8 Hour Drift Voltage 0 01 Eo max Current 0 02 Io max Temperature Coefficient C Voltage 0 01 Eo max Current 0 02 Io max Ripple Noise Voltage rms 0 001 Eo max or 0 3 mV whichever is greater p...

Страница 12: ...ied and proper gage wires not supplied Load Connections 5 wire connection via user configurable mating connector supplied and proper gage wires not supplied DC Power Output 2 wires Output Sense Termin...

Страница 13: ...0 3 6 360 MAT 150 2 4 0 150 0 2 4 360 720W MODULES 2 3 RACK DC OUTPUT RATINGS MAT 6 64 0 6 0 64 384 MAT 15 40 0 15 0 40 600 MAT25 28 0 25 0 28 700 MAT 36 20 0 36 0 20 720 MAT 55 14 0 55 0 14 770 MAT 7...

Страница 14: ...1 6 MAT FULL RACK 022300 FIGURE 1 2 MAT POWER MODULE MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...

Страница 15: ...MAT FULL RACK 022803 1 7 FIGURE 1 2 MAT POWER MODULE MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...

Страница 16: ...es 1 6 ACCESSORIES a Kepco full rack MAT Models are drilled for optional chassis slides Kepco P N 108 0430 modified Jonathan 370 QD Series two required see Figure 1 2 b One 2 meter long shielded twist...

Страница 17: ...t specified by Kepco Inc may impair the pro tection provided by the power supply Observe all safety precautions noted throughout this man ual Table 1 3 lists symbols used on the power supply or in thi...

Страница 18: ...adjust output current of power supply to initial value CONDITIONS current mode shunt at the output A1R20 EO ZERO NOTE 1 Used to adjust output voltage of power supply to zero CONDITIONS voltage mode n...

Страница 19: ...a few seconds before trying again The circuit breaker is trip free design if overload exists or the protection is activated contacts cannot be held closed by actuator 2 VOLTAGE MODE indicator green LE...

Страница 20: ...2 2 for pin designations 2 CONTROL BUS CONNECTORS Connects MAT power module to the IEEE 1118 control bus Two connectors in parallel allow daisy chain connection of up to to 27 MAT power modules to be...

Страница 21: ...the barrier terminal block set to 115 Va c operation Remove the jump ers on the barrier strip connecting terminals 2 to 3 and terminals 4 to 5 3 Place a jumper between terminals 3 and 4 For 230 Va c t...

Страница 22: ...e the limit specified 2 5 INSTALLATION The MAT Power Module is designed to be rack mounted in a standard 19 inch equipment rack refer to Figure 1 2 Mechanical Outline Drawing For installation into con...

Страница 23: ...ned to ground with a single wire This method is dependent on the specific application The MAT Power Modules are designed with Power Isolation relays that comply with MATE Modular Automated Test Equipm...

Страница 24: ...tage drops error sensing is discussed below and minimum inductance error sensing does not compen sate for this Similarly a model for a current stabilized Power Module includes a parallel capaci tor re...

Страница 25: ...NS LOCAL SENSING 2 6 5 LOAD CONNECTION WITH REMOTE ERROR SENSING The MAT series of Power Modules can operate with sensing external to the Module Sensing should be with a twisted wire pair to reduce no...

Страница 26: ...llowing check out uses a MAT Power Module Model 100 10 as an example to the Control Bus Connect the Host Computer and the Power Module Controller to the IEEE 488 GPIB Apply the ac power to the units i...

Страница 27: ...cr lf The Power Module Controller sends back if no errors occur sp cr lf 5 Proceed per PAR 2 8 1 through 2 8 3 substituting full scale voltage current values appropi ate to the model being checked 2 8...

Страница 28: ...entical within the measurement tolerance The meter selection sewitch must be set to voltage for a reading 2 8 2 EXAMPLE 2 FULL SCALE CURRENT CHECK Program the Power Module MAT 100 10 to full scale cur...

Страница 29: ...to the Power Module Controller for example 9 9998 amps which b The Power Module Controller in turn sends 9 9998E0 cr lf 3 Check that the front panel meter reading and the computer are identical withi...

Страница 30: ...r Modules communicates remotely with a controller via the Control Bus Each MAT Power Module has a specific address on the bus The address from 1 to 31 is selected by the switches on the top of the uni...

Страница 31: ...0 3 0 0 0 1 1 4 0 0 1 0 0 5 0 0 1 0 1 6 0 0 1 1 0 7 0 0 1 1 1 8 0 1 0 0 0 9 0 1 0 0 1 10 0 1 0 1 0 11 0 1 0 1 1 12 0 1 1 0 0 13 0 1 1 0 1 14 0 1 1 1 0 15 0 1 1 1 1 16 1 0 0 0 0 17 1 0 0 0 1 18 1 0 0 1...

Страница 32: ...le Controller as an interface to the Host Computer for reporting catastrophic failures within the Power Modules If such an error is reported back to the Power Module Controller the Host Com puter then...

Страница 33: ...his command see the applicable Power Module Controller Manual The required time delay before a valid status of the Power Module Controller MAT system is as follows After an Open Close Change of Polari...

Страница 34: ...bus using either SCPI Standard Commands for Programmable Instruments or CIIL Control Interface Intermediate Language commands SCPI and CIIL provide a common language conforming to IEEE488 2 for instr...

Страница 35: ...different See PAR 3 2 to establish the MAT power supply Control Bus BIT BUS address FIGURE 3 3 TREE DIAGRAM OF SCPI COMMANDS USED WITH MAT POWER SUPPLIES 3 6 2 1 SCPI PROGRAM EXAMPLE Figure 3 4 is an...

Страница 36: ...DEV6 defined by IBCONF bd ibfind GPIB0 Open GPIB card ibsic bd Send Interface Clear ibsre bd 1 Set remote line true strcpy dat_str VOLT 5 CURR 1 Define a set command strcat dat_str r n Append delimite...

Страница 37: ...efer to PAR 3 4 The examples are for a MAT 150 7 model with Control Bus address 9 The ASCII characters for space carriage return and line feed are represented as sp cr and lf respectively The MAT Powe...

Страница 38: ...the current at the output the Host Computer sends FNC DCS CURR CH9 cr lf The MAT at address 9 is now set to take a reading 6 To take a reading the the Host Computer sends INX CURR cr lf a The MAT pre...

Страница 39: ...nds FNC DCS CH9 SET VOLT 120 SET CURL 2 cr lf The MAT at address 9 is then programmed to 120 volts with a current limit of 2 amps 2 To verify the previous command was implemented the Host Computer sen...

Страница 40: ...To reset the Power Module at address 9 the Host Computer sends RST DCS CH9 cr lf The MAT then programs the output to zero and opens the Output Enable relay 9 To verify the previous command was impleme...

Страница 41: ...iously set up now starts to measure and sends the proper time delay needed for the measurement See Par 3 4 b The Power Module Controller will send the time delay back to the Host Computer when it has...

Страница 42: ...mode Description The first operand contains the three 3 letter mnemonic pertaining to the device on the control bus in this case DCS Direct Current Source If a reading is being set up the modifier VOL...

Страница 43: ...or the command may be repeated until a zero value is returned but the preceding FTH command must also be repeated Example INX VOLT Power supply initiates voltage reading FTH VOLT Power supply sends v...

Страница 44: ...e MAT power supply allows 12 bits or 024 of maximum rated voltage or current It can be directly specified in ASCII integer decimal or in scientific notation There may be two 2 set commands separated b...

Страница 45: ...a power supply to its power on state The output voltage and current are programmed to zero and the output relay of MR and MGR models is opened Example RST DCS CH13 The power supply at node address 13...

Страница 46: ...e A shutdown occurred due to thermal causes F07 DCSnn DEV Overload The voltage or current limit point was exceeded F07 DCSnn DEV Voltage Fault The output voltage is not within limits voltage mode F07...

Отзывы: