KLN 750W 121912
2-9
FIGURE 2-5. LOAD CONNECTION TERMINALS FOR 6V - 150V MODELS
Kepco strongly recommends the use of stranded (not solid) wire with (+) and (–) wires tightly
twisted to reduce self-inductance; wire end ferrules are suggested to prevent fraying of the
strands.
NOTE
REGARDLESS OF OUTPUT CONFIGURATION, EITHER LOCAL OR REMOTE OUT-
PUT SENSE LINES SHOULD BE CONNECTED FOR OPTIMUM OPERATION.
• OBSERVE POLARITIES: The +S sensing wire must be connected to the (+) load wire,
and the –S sensing wire must be connected to the (–) load wire.
• IF LOCAL SENSING IS USED: Install red and black sense leads supplied (see Figure 2-
6).
2.5.6
LOAD CONNECTION USING LOCAL SENSING
Figure 2-6 shows a typical configuration using local sensing. Local sensing is recommended for
a high noise or switching mode load such as d-c to d-c or d-c to a-c.
CAUTION: CS ONLY TO + AND –S ONLY TO –. CONNS TO –S, +V
TO –S, OR –V TO +S WILL DAMAGE THE UNIT.
FIGURE 2-6. LOAD CONNECTIONS, LOCAL SENSING