HSF(A) 300W 040215

3

FIGURE 2.  POWER RATING VS. TEMPERATURE

TABLE 2.  HSF 300W (A, AM) OUTPUT RATINGS AND SPECIFICATIONS

HSF (A, AM) MODEL 

5-60A, AM

12-27A, AM

15-22A, AM

24-14A, AM

28-12A, AM

48-7A, AM

Output Volts d-c (nominal)

5

12

15 

24

28

48

Output

Adjustment

Range

(1)

(Volts d-c)

(2) 

SW1 pos 7 OFF 

(default)

2 to 5.5

4.8 to 13.8

6 to 17.4 

9.6 to 28.2 

9.6 to 29.0

19.2 to 52.2

SW1 pos 7 ON

0 to 5.5

0 to 13.8

0 to 17.4 

0 to 28.2 

0 to 29.0

0 to 52.2

Output Current (nominal) (Amps)

60

27

22

14

12

7

Maximum Output Power (Watts)

(3)

 300

300

300

300

300

300

Current Limit Setting (Amps)

(4)(5)

63

28.4

23.1

16.7

16.7

7.4

Overvoltage Protection (OVP) 

(Volts d-c)

(6)

5.75 - 6.75

14.5 - 16.9

18.3 - 21.3

29.5 - 34.3

29.5 - 34.3

54.7 - 63.9

Efficiency 

(% typ.)

AC Input 100V

71

76

77

80

80

81

AC Input 200V

73

79

80

83

83

84

Maximum Ripple 

& Noise

(7)

 

(mV, p-p)

0°C 



70°C

120

150

150

150

150

350

-10°C 



0°C

180

200

200

200

200

400

(1)

To adjust output voltage down to approximately 0V requires that DIP SW1, position 7 be set to ON. Refer to Table 5 for mini-
mum conditions required to maintain proper operation of alarm relay, meter (AM Models only) and VDC ON/ALARM indica-
tor.

(2)

Using trimpot to attain voltages outside the specified adjustment range may trigger overvoltage (PAR 3.6.1) faults. Recovery 
is by removing, and after approximately 40 seconds, reapplying AC input power or by reset (open and close) at ±RC termi-
nals (no delay).

(3)

See Figure 2 for power derating.

(4)

CAUTION: The unit may be damaged if operated under overcurrent or shorted conditions for more than 30 seconds. If cur-
rent exceeds limit (5% of nominal), output voltage starts to drop. If overload condition continues, current up to 130% of nom-
inal may be experienced.

(5)

Constant current limit with automatic recovery, except 5V model: constant current limit with hiccup and automatic recovery 
(see PAR. 3.6.2).

(6)

When overvoltage is detected, output is shut OFF. Recovery is by removing, and after approximately 40 seconds, reapplying 
AC input power or by reset (open and close) at ±RC terminals (no delay).

(7)

Measure with JEITA RC-9131A probe, bandwidth of scope: 100MHz.

!

Содержание HSF A

Страница 1: ...serial number 3 The contents of this manual are protected by copyright Reproduction of any part can be made only with the specific written permission of Kepco Inc Data subject to change without notice...

Страница 2: ...g Latches 15 4 Load Connection 16 5 Connecting Multiple Power Supplies 16 1 HSF A AM Rear Panel Connector and RA 19 4C Rack Adapter I O Connector 1 2 Power Rating Vs Temperature 3 3 Mechanical Outline...

Страница 3: ...nd are designed to operate in a fault tolerant power sys tem Input voltage range is single phase 85 265V a c 47 63Hz or 120 330V d c Input voltage which is out of specification may cause unit damage S...

Страница 4: ...ay see PAR 3 7 2 1 REF 15 Reference voltage When used with RV pin 18 allows all output voltages of paralleled slave supplies to be controlled by one voltage adjustment of a master power supply When RE...

Страница 5: ...es that DIP SW1 position 7 be set to ON Refer to Table 5 for mini mum conditions required to maintain proper operation of alarm relay meter AM Models only and VDC ON ALARM indica tor 2 Using trimpot t...

Страница 6: ...load change Current Sharing 10 100 load change Temperature Coefficient 0 02 per C Combined Effect 1 2 Typical 2 2 Maximum Source Load and Temperature Time Effect 0 2 Typical 0 5 Maximum 1 2 to 8 hours...

Страница 7: ...B VCCI Class B EN55011 B EN55022 B EMC Emission Radiated Designed to meet FCC Class B VCCI Class B EN55011 B EN55022 B EMC Power Factor Harmonic Current PFHC Designed to meet EN61000 3 2 EMC Immunity...

Страница 8: ...4 0 093 2 4 0 127 3 2 0 430 10 9 2 065 52 5 3 353 85 2 0 337 8 5 0 085 2 2 0 204 5 2 0 090 2 3 0 943 23 9 2 408 61 2 0 438 11 1 0 394 10 0 3 216 81 7 0 606 15 4 0 690 17 5 FRONT VIEW REAR VIEW SEE RE...

Страница 9: ...6 CSB 1 OFF Enables Current Share always off ON N A 6 CSB 1 OFF N A ON Enables Current Share always on 7 COM to S OFF Isolates COM from S ON Connects COM to S 7 VADJ to 0 OFF Vadj adjusts output per T...

Страница 10: ...established at the factory The output voltage determines which key pins are installed see Figure 3 Detail A When the proper holes in the rack adapter are blocked by keying screws installed by the user...

Страница 11: ...re unit is removed from the rack adapter Retaining Latches 2 Prevents inadvertent removal of unit from rack adapter see PAR 3 9 AM Models only Voltage Current meter Monitors out put voltage or current...

Страница 12: ...fied in Table 2 To ensure proper operation of the alarm relay meter AM Models only and VDC ON ALARM indicator do not adjust the external voltage below minimum listed in Table 5 Using External Resistan...

Страница 13: ...be isolated from DC output or from PF signal TABLE 5 MINIMUM CONDITIONS FOR RELAY METER AND LED OPERATION HSF A AM MODEL 5 60A AM 12 27A AM 15 22A AM 24 14A AM 28 12A AM 48 7A AM For HSF A and AM mode...

Страница 14: ...wait until unit cools then set the POWER switch to ON The power supply cannot be reset using the remote ON OFF feature unless the power supply remains shut down for at least 40 seconds 3 6 2 OVERCURR...

Страница 15: ...he VDC ON ALARM indicator can be disabled by setting DIP switch 1 position 8 to OFF 3 7 2 ALARM SIGNALS Either of two options are available for signalling alarms isolated relay contacts factory defaul...

Страница 16: ...the transistor cuts off and the collector emitter cir cuit is open Figure 12 is a timing diagram of the power fail signal The default state of the alarm is logic low The sink current for the optocoup...

Страница 17: ...conjunction with the RA 19 4C rack adapters to prevent unauthorized or inadvertent module extraction from an operating power system The latch is engaged by loosening the cap head screw approximately 1...

Страница 18: ...e the difference between voltage settings of parallel con nected units should be less than 0 5 of the nominal voltage value of the units Output voltage adjustment should be done at same load for each...

Отзывы: